CGCarlo Giordano

Carlo Giordano

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Carlo Giordano has a total of 58 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Conversion factors between whole-body and organ doses in interventional cardiology: an italian multicentre study

    by Carlo Giordano, Sara Vitali, Maria Garioni, Jessika Camatti, Alessandra Terulla, Piergiorgio Marini, Loredana D’ERcole

    The increasing use of ionizing radiation in interventional cardiology raises the need for reliable estimates of operator exposure, particularly for organs such as the eyes and hands. This retrospective study analyzed personal dosimetry records from interventional cardiologists working in three Italian hospitals. A total of 1,897 valid dosimetry measurements were analyzed across three centres, including whole-body Hp(10), eye lens Hp(3), and extremity Hp(0.07) doses. We derived the following conversion factors by using the third quartile of the ratio distributions from all centres: Hp(3)/Hp(10):1.1 and Hp(0.07)/Hp(10): 2.7. However, our data show high variability across all centres, which probably reflects differences in procedure complexity and operator positioning observed in routine interventional cardiology practice. These findings support the use of whole-body dosimetry as a practical surrogate for organ dose assessment when eye lens or extremity monitoring is unavailable. The proposed conversion factors (Hp(3)/Hp(10) = 1.1 and Hp(0.07)/Hp(10) = 2.7) provide a conservative and field-applicable tool to retrospectively estimate lens and hand doses in cases of incomplete dosimetry.


  • Open Access

    Radiation Exposure during Fluoroscopy-Guided Ozone Chemonucleolysis for Lumbar Disc Herniation

    by Matteo Luigi Giuseppe Leoni, Sara Vitali, Fabrizio Micheli, Marco Mercieri, Giustino Varrassi, Roberto Casale, Felice Occhigrossi, Carlo Giordano

    Introduction: Radiation exposure is a frequent drawback of spinal surgery, even if X-ray guidance plays a pivotal role in improving the accuracy and safety of spinal procedures. Consequently, radiation protection is essential to reduce potential negative biological effects. The aim of this study was to evaluate patients’ radiation exposure, the radiation dose emission during fluoroscopy-guided ozone chemonucleolysis (OCN), and the potential role of patient characteristics. Methods: The radiation dose emission reports were retrospectively evaluated in patients who underwent single-level OCN for lumbar disc herniation. A generalized linear model (GLM) with a gamma distribution and log link function was used to assess the association between radiation emission and patients’ characteristics such as age, sex, BMI, level of disc herniation, disc height, and site of disc herniation. Results: Two hundred and forty OCN cases were analyzed. A safe and low level of radiation exposure was registered during OCN. The median fluoroscopy time for OCN was 26.3 (19.4–35.9) seconds, the median radiation emission dose was 19.3 (13.2–27.3) mGy, and he median kerma area product (KAP) was 0.46 (0.33–0.68) mGy ⋅ m2. The resulting KAP values were highly dependent on patient variables. In particular, sex, obesity, and residual disc height < 50% significantly increased the measured KAP, while levels of disc herniations other than L5-S1 reduced the KAP values. Conclusions: The radiation exposure during OCN is low and quite similar to a simple discography. However, patient characteristics are significantly related to radiation exposure and should be carefully evaluated before planning OCN.


  • A single phantom, a single statistical method for low-contrast detectability assessment

    by Nicoletta Paruccini, Raffaele Villa, Nadia Oberhofer, Alessandro Loria, Michele Signoriello, Carlo Giordano, Raffaella Soavi, Paola Colombo, Cristina De Mattia, Federica Rottoli, et al.


  • LOCAL LEVELS OF PATIENT RADIATION EXPOSURE IN A UROLOGY OPERATING ROOM IN ITALY

    by C Giordano, G Marcello, L Barbattini, R Gobbi

    The data analysed came from 545 patients and were related to five types of procedures performed in the urology operating room: percutaneous nephrolithotomy (PCNL), retrograde intrarenal surgery (RIRS), ureteropyeloscopy (UPS), ureteral catheterisation and nephrostomy. Local reference levels (75th percentiles) were determined for the various procedures. The peak entrance skin dose for a patient 20 cm thick was highest for PCNL, being 82 mGy, followed by 43 mGy for nephrostomy, 23 mGy for RIRS, 23 mGy for UPS and 17 mGy for stenting. Even taking into account the maximum values measured (296 mGy for UPS), the doses reached at the skin were not such as to cause deterministic effects. However, the threshold dose for male temporary sterility could be reached (150 mGy).


  • DETERMINATION OF LOCAL LEVELS OF RADIATION EXPOSURE IN ORTHOPEDIC INTERVENTIONS USING STRUCTURED DOSE REPORT DATA DRAWN FROM THE HOSPITAL PICTURE ARCHIVING AND COMMUNICATION SYSTEM

    by Carlo Giordano, Ivo Monica, Rossana Gobbi, Lorenzo Barbattini

    The aim of this study was to determine the dosimetric parameters of radiation to which orthopedic in-patients are exposed, using data drawn from the hospital's picture archiving and communication system. Data for 310 patients, relating to seven different anatomical districts, were examined. Femoral operations were divided into three types. The 75th percentile dose at the interventional reference point (IRP) exceeded 2 mGy only for femoral interventions (4.6-6.2 mGy) with 75th percentile kerma-area product (KAP) values ranging from 84.8 to 109.1 mu Gy m(2). The 75th percentile fluoroscopy time was longer than 1 min only for the humeral operations and the three types of femoral intervention. In general, the radiation exposure times and doses recorded in our institute were lower than those reported in the literature. The correlation between KAP and kerma at the IRP was very strong for all districts (R > 0.80). The correlation between KAP and fluoroscopy times was very strong for seven cases (R > 0.80), and strong for two (0.60 < R < 0.79).


  • Benign paroxysmal positional vertigo and orthostatic hypotension

    by Matteo Pezzoli, Massimiliano Garzaro, Giancarlo Pecorari, Manuele Cena, Carlo Giordano, Roberto Albera

    The aim of this study was to investigate a possible correlation between post-benign paroxysmal positional vertigo (BPPV) dizziness and orthostatic hypotension (OH) using the head-up tilt test (HUTT). Twenty-nine patients previously affected by BPPV and successfully underwent repositioning maneuvers were tested using the HUTT. Our data do not show a statistically significant relationship between OH and the persistence of balance disorders after recovery from BPPV; anyway the prevalence of OH in the overall sample (34%) and in subjects affected by balance disorders after recovery (40%), was higher than in the general population. it is reasonable to hypothesize that OH plays a role in the genesis of orthostatic dizziness that patients commonly experience after recovery from BPPV. To improve the sensitivity of the HUTT, it would be advisable to use non-invasive continuous blood pressure monitoring. Although we feel that additional data are needed, we believe that the present work underlines the importance of considering anomalies of the autonomic system in the differential diagnosis of dizziness and could offer the basis for further studies about the role of sympathetic reflexes in those cases of persistence of symptoms after recovery from BPPV.