Evolution of customization design for total knee arthroplasty
- 29 September 2012
- journal article
- Published by Springer Nature in Current Reviews in Musculoskeletal Medicine
- Vol. 5 (4) , 290-295
Abstract
Total Knee Arthroplasty (TKA) is a highly successful surgical procedure with more than 600,000 TKA’s performed annually in the US. Interest in improving surgical outcomes has led to improvements in surgical technique, instrumentation, and implant design. Computer navigation and robotic systems were introduced to further refine the mechanical alignment of joint replacement procedures. The cost to implement some of these technologies and the additional time required in the operating room to utilize these developments has limited the acceptance of them broadly. The introduction of custom instrumentation and cutting blocks based on computed tomography (CT) or magnetic resonance imaging (MRI) has allowed for better restoration of mechanical alignment. Unfortunately, little has changed in patient satisfaction in the past ten years. The recent introduction of patient specific instrumentation and patient specific implants is another step forward to restore the pre-deformity anatomy and joint geometry. This new technology can benefit the hospital by improving operating room time efficiencies through having shorter set-up times, and the elimination of cleaning, sterilization and inventory costs. The patient can potentially benefit by a shorter operative time, improved postoperative alignment and better fitting implants.Keywords
This publication has 19 references indexed in Scilit:
- Overhang of the Femoral Component in Total Knee Arthroplasty: Risk Factors and Clinical ConsequencesJournal of Bone and Joint Surgery, 2010
- Patient Satisfaction after Total Knee Arthroplasty: Who is Satisfied and Who is Not?Clinical Orthopaedics and Related Research, 2010
- Unicompartmental Knee Arthroplasty with Use of Novel Patient-Specific Resurfacing Implants and Personalized JigsJournal of Bone and Joint Surgery, 2009
- Custom-Fit Total Knee Arthroplasty (OtisKnee) Results in MalalignmentThe Journal of Arthroplasty, 2008
- Meta-Analysis of Alignment Outcomes in Computer-Assisted Total Knee Arthroplasty SurgeryThe Journal of Arthroplasty, 2007
- The John Insall Award: Patient Expectations Affect Satisfaction with Total Knee ArthroplastyClinical Orthopaedics and Related Research, 2006
- Custom Patellofemoral Arthroplasty of the KneeJournal of Bone and Joint Surgery, 2006
- Computer-assisted Total Knee Arthroplasty Using Patient-specific TemplatingClinical Orthopaedics and Related Research, 2006
- In Vivo Anteroposterior Femorotibial Translation of Total Knee ArthroplastyClinical Orthopaedics and Related Research, 1998
- In Vivo Knee Kinematics Derived Using an Inverse Perspective TechniqueClinical Orthopaedics and Related Research, 1996