Theoretical Comparison of Aberration-correcting Customized and Aspheric Intraocular Lenses
- 1 April 2007
- journal article
- research article
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 23 (4) , 374-384
Abstract
Purpose: To assess the performance and optical limitations of standard, aspheric, and wavefront-customized intraocular lenses (IOLs) using clinically verified pseudo-phakic eye models. Methods: White light pseudophakic eye models were constructed from physical measurements performed on 46 individual cataract patients and subsequently verified using the clinically measured contrast sensitivity function (CSF) and wavefront aberration of pseudophakic patients implanted with two different types of IOLs. These models are then used to design IOLs that correct the astigmatism and higher order aberrations of each individual eye model's cornea and to investigate how this correction would affect visual benefit, subjective tolerance to lens misalignment (tilt, decentration, and rotation), and depth of field. Results: Physiological eye models and clinical outcomes show similar levels of higher order aberration and contrast improvement. Customized correction of ocular wavefront aberrations with an IOL results in contrast improvements on the order of 200% over the control and the Tecnis IOLs. The customized lenses can be, on average, decentered by as much as 0.8 mm, tilted >10°, and rotated as much as 15° before their polychromatic modulation transfer function at 8 cycles/degree is less than that of the Tecnis or spherical control lens. Correction of wavefront aberration results in a narrower through focus curve but better out of focus performance for ±0.50 diopters. Conclusions: The use of realistic eye models that include higher order aberrations and chromatic aberrations are important when determining the impact of new IOL designs. Customized IOLs show the potential to improve visual performance. [ J Refract Surg . 2007;23:374–384.]Keywords
This publication has 66 references indexed in Scilit:
- Improved functional vision with a modified prolate intraocular lensJournal of Cataract & Refractive Surgery, 2004
- Using the lens haptic plane concept and thick-lens ray tracing to calculate intraocular lens powerJournal of Cataract & Refractive Surgery, 2004
- High-order aberrations in pseudophakia with different intraocular lensesJournal of Cataract & Refractive Surgery, 2004
- Improvement in retinal image quality with dynamic correction of the eye’s aberrationsOptics Express, 2001
- Analysis of the performance of the Hartmann–Shack sensor in the human eyeJournal of the Optical Society of America A, 2000
- Correction of the aberrations in the human eye with a liquid-crystal spatial light modulator: limits to performanceJournal of the Optical Society of America A, 1998
- Tilt and decentration of bag-fixated intraocular lenses: A comparative study between capsulorhexis and envelope techniquesDocumenta Ophthalmologica, 1994
- Spectral sensitivities of the human conesJournal of the Optical Society of America A, 1993
- Influence of Field Size on the Spectral Sensitivity of the Eye in the Photopic and Mesopic RangeOptometry and Vision Science, 1985
- Colorimetric and photometric properties of a 2° fundamental observerColor Research & Application, 1978