PPPatricia A. Piers

Patricia A. Piers

*This is an algorithmically generated author record based on publicly available information.

Patricia A. Piers has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Use of adaptive optics to determine the optimal ocular spherical aberration

    by Patricia A. Piers, Silvestre Manzanera, Pedro M. Prieto, Nicolas Gorceix, Pablo Artal

    To explore the impact of spherical aberration (SA) on contrast sensitivity using an adaptive optics vision simulator to determine the optimal amount of SA to include in customized corrections of wavefront aberrations. Laboratorio de Optica, Universidad de Murcia, Murcia, Spain, and AMO Groningen BV, Groningen, The Netherlands. An adaptive optics vision simulator consisting of a wavefront sensor, a 97-segmented deformable mirror to induce and correct aberrations of the eye, and a visual testing path was constructed for this study. The deformable mirror allows the effective ocular wavefront aberration to be manipulated and the resulting visual performance to be measured simultaneously. Subjective measurements of contrast sensitivity at 15 cycles per degree were performed with a 4.8 mm pupil in 5 subjects with different levels of naturally occurring SA. Contrast sensitivity was measured when SA values of -0.09 microm, 0.0 microm, 0.09 microm, and 0.182 microm were induced when the other natural aberrations of the eye were present, when the aberrations were corrected, and at defocus values of +/-0.25 diopter (D) and +/-0.50 D. Subjects experienced peak contrast sensitivity performance with varying levels of SA when their natural aberrations were present; however, average contrast performance peaked at 0 mum of SA. When all higher-order aberrations were corrected, all 5 subjects' peak performance occurred at 0 microm of SA. The adaptive optics vision simulator reduced the root-mean-square wavefront aberration of the eye by up to a factor of 4 and allowed noninvasive testing of the visual performance resulting from any ocular wavefront aberration introduced by customized correction procedures. This study showed that, on average, contrast performance peaked when SA was completely corrected.


  • Theoretical Comparison of Aberration-correcting Customized and Aspheric Intraocular Lenses

    by Patricia A. Piers, Henk A. Weeber, Pablo Artal, Sverker Norrby

    Purpose: To assess the performance and optical limitations of standard, aspheric, and wavefront-customized intraocular lenses (IOLs) using clinically verified pseudo-phakic eye models. Methods: White light pseudophakic eye models were constructed from physical measurements performed on 46 individual cataract patients and subsequently verified using the clinically measured contrast sensitivity function (CSF) and wavefront aberration of pseudophakic patients implanted with two different types of IOLs. These models are then used to design IOLs that correct the astigmatism and higher order aberrations of each individual eye model's cornea and to investigate how this correction would affect visual benefit, subjective tolerance to lens misalignment (tilt, decentration, and rotation), and depth of field. Results: Physiological eye models and clinical outcomes show similar levels of higher order aberration and contrast improvement. Customized correction of ocular wavefront aberrations with an IOL results in contrast improvements on the order of 200% over the control and the Tecnis IOLs. The customized lenses can be, on average, decentered by as much as 0.8 mm, tilted >10°, and rotated as much as 15° before their polychromatic modulation transfer function at 8 cycles/degree is less than that of the Tecnis or spherical control lens. Correction of wavefront aberration results in a narrower through focus curve but better out of focus performance for ±0.50 diopters. Conclusions: The use of realistic eye models that include higher order aberrations and chromatic aberrations are important when determining the impact of new IOL designs. Customized IOLs show the potential to improve visual performance. [ J Refract Surg . 2007;23:374–384.]


  • Adaptive Optics Simulation of Intraocular Lenses with Modified Spherical Aberration

    by Patricia A. Piers, Enrique J. Fernandez, Silvestre Manzanera, Sverker Norrby, Pablo Artal

    Purpose. Adaptive optics systems can be used to investigate the potential visual benefit associated with correcting ocular wave-front aberration. In this study, adaptive optics techniques were used to evaluate the potential advantages and disadvantages associated with intraocular lenses (IOLs) with modified spherical aberration profiles.