Comparative Study of the Usefulness of the Binocular Spot Vision Screener Autorefractor in the Detection of Childhood Visual Disorders
Authors:
- 28 March 2018
- journal article
- research article
- Published by Georg Thieme Verlag KG in Klinische Monatsblätter für Augenheilkunde
- Vol. 235 (04) , 416-419
Abstract
Background The Spot Vision Screener (SVS) is designed to detect significant ametropia, anisometropia, and strabismus in non-dilated eyes. This study evaluates the efficacy of the SVS in paediatric visual screening. Patients and Methods All children screened during the paediatric visual screening day in Lausanne in 2016 were evaluated with the SVS, conventional monocular autorefractors, and clinical orthoptic examination. Recommendations for a further eye examination of the SVS were compared with those issued from traditional clinical screenings (monocular refraction and orthoptic examination). Results One hundred and sixty-eight consecutive children were included. The median age was 3.9 years. The SVS median spherical equivalent (SE) was + 0.25 D OU and it detected seven cases of (4.2%) anisometropia (SE difference ≥ 1 D). The conventional monocular autorefractor median SE was − 0.13 D OU and 20 cases of anisometropia (11.9%) were detected. Refraction could not be measured in 1.2% of patients with SVS versus 17.2% with monocular refractors. The SVS screened two manifest strabismus cases against five manifest and > 100 latent strabismus with orthoptic examination. As expected, the SVS was unable to assess reactions to monocular occlusion, visual acuity, and stereovision as well as to detect ocular motility disorders without strabismus in the primary position, and missed two cases of abnormal Brückner reflexes. Overall, the SVS identified 66 suspect patients (39.3%) against 102 (60.7%) after complete clinical examination. Conclusions The SVS can be a useful objective screening tool for non-ophthalmologists. However, because it fails to detect ocular motility troubles, organic visual acuity loss, or to assess the visual potential, it should only be used in association with a clinical examination, even in routine screening procedures.Keywords
This publication has 10 references indexed in Scilit:
- Performance of the Spot Vision Screener in Children Younger Than 3 Years of AgeAmerican Journal of Ophthalmology, 2017
- Detecting High Hyperopia: The Plus Lens Test and the Spot Vision ScreenerJournal of Pediatric Ophthalmology & Strabismus, 2017
- Validation of photoscreening technology in the general pediatrics office: a prospective studyJournal of American Association for Pediatric Ophthalmology and Strabismus, 2016
- Performance of Spot Photoscreener in Detecting Amblyopia Risk Factors in Chinese Pre-school and School Age Children Attending an Eye ClinicPLOS ONE, 2016
- Detection of strabismus by the Spot Vision ScreenerJournal of American Association for Pediatric Ophthalmology and Strabismus, 2015
- Evaluation of the Spot Vision Screener in young children in Costa RicaJournal of American Association for Pediatric Ophthalmology and Strabismus, 2015
- Validation of Spot screening device for amblyopia risk factorsJournal of American Association for Pediatric Ophthalmology and Strabismus, 2014
- Performance of the Spot vision screener for the detection of amblyopia risk factors in childrenJournal of American Association for Pediatric Ophthalmology and Strabismus, 2014
- Performance of Four New Photoscreeners on Pediatric Patients With High Risk AmblyopiaJournal of Pediatric Ophthalmology & Strabismus, 2014
- Results of a community vision-screening program using the Spot photoscreenerJournal of American Association for Pediatric Ophthalmology and Strabismus, 2013