Evaluation of a bioaerosol sampler for indoor environmental surveillance of Severe Acute Respiratory Syndrome Coronavirus 2
Open Access
- 15 November 2021
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 16 (11) , e0257689
Abstract
The worldwide spread of Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) has ubiquitously impacted many aspects of life. As vaccines continue to be manufactured and administered, limiting the spread of SARS-CoV-2 will rely more heavily on the early identification of contagious individuals occupying reopened and increasingly populated indoor environments. In this study, we investigated the utility of an impaction-based bioaerosol sampling system with multiple nucleic acid collection media. Heat-inactivated SARS-CoV-2 was utilized to perform bench-scale, short-range aerosol, and room-scale aerosol experiments. Through bench-scale experiments, AerosolSense Capture Media (ACM) and nylon flocked swabs were identified as the highest utility media. In room-scale aerosol experiments, consistent detection of aerosol SARS-CoV-2 was achieved at an estimated aerosol concentration equal to or greater than 0.089 genome copies per liter of room air (gc/L) when air was sampled for eight hours or more at less than one air change per hour (ACH). Shorter sampling periods (75 minutes) yielded consistent detection at ~31.8 gc/L of room air and intermittent detection down to ~0.318 gc/L at (at both 1 and 6 ACH). These results support further exploration in real-world testing scenarios and suggest the utility of indoor aerosol surveillance as an effective risk mitigation strategy in occupied buildings.Keywords
All Related Versions
Funding Information
- Thermo Fisher Scientific (4133V1)
This publication has 65 references indexed in Scilit:
- Swabs as a Tool for Monitoring the Presence of Norovirus on Environmental Surfaces in the Food IndustryJournal of Food Protection, 2013
- Evaluation of commercial kits for the extraction and purification of viral nucleic acids from environmental and fecal samplesJournal of Virological Methods, 2013
- The Effects of Temperature and Relative Humidity on the Viability of the SARS CoronavirusAdvances in Virology, 2011
- The use of FTA® filter papers for diagnosis of avian influenza virusJournal of Virological Methods, 2011
- Effects of Air Temperature and Relative Humidity on Coronavirus Survival on SurfacesApplied and Environmental Microbiology, 2010
- Comparison of Polyurethane Foam to Nylon Flocked Swabs for Collection of Secretions from the Anterior Nares in Performance of a Rapid Influenza Virus Antigen Test in a Pediatric Emergency DepartmentJournal of Clinical Microbiology, 2010
- Dry cotton or flocked respiratory swabs as a simple collection technique for the molecular detection of respiratory viruses using real-time NASBAJournal of Virological Methods, 2008
- Comparison of nasopharyngeal flocked swabs and aspirates for rapid diagnosis of respiratory viruses in childrenJournal of Clinical Virology, 2008
- Effects of humidity and other factors on the generation and sampling of a coronavirus aerosolAerobiologia, 2007
- Use of Bacteriophage MS2 as an Internal Control in Viral Reverse Transcription-PCR AssaysJournal of Clinical Microbiology, 2005