Kevin Van Den Wymelenberg
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kevin Van Den Wymelenberg has a total of 131 co-authors. Here are the top co-authors by number of shared publications:
- Patrick Finn Horve
University of Oregon
13 shared publications - Leslie Dietz
University of Oregon
10 shared publications Mark Fretz
Institute for Health and the Built Environment, University of Oregon, Portland, USA
7 shared publicationsDale Northcutt
Biology and the Built Environment Center, University of Oregon, Eugene, USA
6 shared publications- Hooman Parhizkar
Institute for Health in the Built Environment, University of Oregon, Eugene, Oregon
6 shared publications - Mark Fretz
Institute for Health in the Built Environment, University of Oregon, Portland, Oregon
6 shared publications
Latest Publications
- Open Access
Impact of Wood on Perception of Transient and Steady-State Indoor Thermal Environments
Wood is often used as an interior surface finish in buildings, including exposed cross-laminated timber panels and other structural mass timber members. Building occupants generally have a positive reaction to visible wood elements used in building interiors due to the visual qualities associated with wood being a natural material. This study aims to identify any thermal comfort impacts of wood interior environments using subjective occupant-reported perceived thermal sensation during two experiments conducted in a climate chamber fitted with either white-painted gypsum wallboard or unfinished laminated Douglas Fir wall panels. In the first experiment, the thermal environment was continually varied while the visual stimulus of the wall type remained constant. Irrespective of wood or white wall treatment type, thermal history played a significant role in the perceived thermal comfort of participants under continually modulating temperatures. In the second experiment, a slightly warm steady-state thermal environment was maintained while one of the two wall treatments was revealed from behind a black curtain. While the shift in thermal sensation toward neutral was greater with wood walls than with white walls, the difference was not found to be statistically significant and appears to diminish after 15 min of exposure to the new visual surroundings.
Open AccessImpact of Wood on Perception of Transient and Steady-State Indoor Thermal Environments
Wood is often used as an interior surface finish in buildings, including exposed cross-laminated timber panels and other structural mass timber members. Building occupants generally have a positive reaction to visible wood elements used in building interiors due to the visual qualities associated with wood being a natural material. This study aims to identify any thermal comfort impacts of wood interior environments using subjective occupant-reported perceived thermal sensation during two experiments conducted in a climate chamber fitted with either white-painted gypsum wallboard or unfinished laminated Douglas Fir wall panels. In the first experiment, the thermal environment was continually varied while the visual stimulus of the wall type remained constant. Irrespective of wood or white wall treatment type, thermal history played a significant role in the perceived thermal comfort of participants under continually modulating temperatures. In the second experiment, a slightly warm steady-state thermal environment was maintained while one of the two wall treatments was revealed from behind a black curtain. While the shift in thermal sensation toward neutral was greater with wood walls than with white walls, the difference was not found to be statistically significant and appears to diminish after 15 min of exposure to the new visual surroundings.
- Open Access
- 23 November 2022
- Published by Springer Nature in Journal of Exposure Science & Environmental Epidemiology
- Vol. 33 (3) , 339-346
A novel VOC breath tracer method to evaluate indoor respiratory exposures in the near- and far-fields; implications for the spread of respiratory viruses
Background: Several studies suggest that far-field transmission (>6 ft) explains a significant number of COVID-19 superspreading outbreaks.Objective: Therefore, quantifying the ratio of near- and far-field exposure to emissions from a source is key to better understanding human-to-human airborne infectious disease transmission and associated risks.Methods: In this study, we used an environmentally-controlled chamber to measure volatile organic compounds (VOCs) released from a healthy participant who consumed breath mints, which contained unique tracer compounds. Tracer measurements were made at 0.76 m (2.5 ft), 1.52 m (5 ft), 2.28 m (7.5 ft) from the participant, as well as in the exhaust plenum of the chamber.Results: We observed that 0.76 m (2.5 ft) trials had ~36–44% higher concentrations than other distances during the first 20 minutes of experiments, highlighting the importance of the near-field exposure relative to the far-field before virus-laden respiratory aerosol plumes are continuously mixed into the far-field. However, for the conditions studied, the concentrations of human-sourced tracers after 20 minutes and approaching the end of the 60-minute trials at 0.76 m, 1.52 m, and 2.28 m were only ~18%, ~11%, and ~7.5% higher than volume-averaged concentrations, respectively.Significance: This study suggests that for rooms with similar airflow parameters disease transmission risk is dominated by near-field exposures for shorter event durations (e.g., initial 20–25-minutes of event) whereas far-field exposures are critical throughout the entire event and are increasingly more important for longer event durations.Impact statement: We offer a novel methodology for studying the fate and transport of airborne bioaerosols in indoor spaces using VOCs as unique proxies for bioaerosols. We provide evidence that real-time measurement of VOCs can be applied in settings with human subjects to estimate the concentration of bioaerosol at different distances from the emitter. We also improve upon the conventional assumption that a well-mixed room exhibits instantaneous and perfect mixing by addressing spatial distances and mixing over time. We quantitatively assessed the exposure levels to breath tracers at alternate distances and provided more insights into the changes on “near-field to far-field” ratios over time. This method can be used in future to estimate the benefits of alternate environmental conditions and occupant behaviors.
- 23 November 2022
- Published by Springer Nature in Journal of Exposure Science & Environmental Epidemiology
- Vol. 33 (3) , 339-346
Open AccessA novel VOC breath tracer method to evaluate indoor respiratory exposures in the near- and far-fields; implications for the spread of respiratory viruses
Background: Several studies suggest that far-field transmission (>6 ft) explains a significant number of COVID-19 superspreading outbreaks.Objective: Therefore, quantifying the ratio of near- and far-field exposure to emissions from a source is key to better understanding human-to-human airborne infectious disease transmission and associated risks.Methods: In this study, we used an environmentally-controlled chamber to measure volatile organic compounds (VOCs) released from a healthy participant who consumed breath mints, which contained unique tracer compounds. Tracer measurements were made at 0.76 m (2.5 ft), 1.52 m (5 ft), 2.28 m (7.5 ft) from the participant, as well as in the exhaust plenum of the chamber.Results: We observed that 0.76 m (2.5 ft) trials had ~36–44% higher concentrations than other distances during the first 20 minutes of experiments, highlighting the importance of the near-field exposure relative to the far-field before virus-laden respiratory aerosol plumes are continuously mixed into the far-field. However, for the conditions studied, the concentrations of human-sourced tracers after 20 minutes and approaching the end of the 60-minute trials at 0.76 m, 1.52 m, and 2.28 m were only ~18%, ~11%, and ~7.5% higher than volume-averaged concentrations, respectively.Significance: This study suggests that for rooms with similar airflow parameters disease transmission risk is dominated by near-field exposures for shorter event durations (e.g., initial 20–25-minutes of event) whereas far-field exposures are critical throughout the entire event and are increasingly more important for longer event durations.Impact statement: We offer a novel methodology for studying the fate and transport of airborne bioaerosols in indoor spaces using VOCs as unique proxies for bioaerosols. We provide evidence that real-time measurement of VOCs can be applied in settings with human subjects to estimate the concentration of bioaerosol at different distances from the emitter. We also improve upon the conventional assumption that a well-mixed room exhibits instantaneous and perfect mixing by addressing spatial distances and mixing over time. We quantitatively assessed the exposure levels to breath tracers at alternate distances and provided more insights into the changes on “near-field to far-field” ratios over time. This method can be used in future to estimate the benefits of alternate environmental conditions and occupant behaviors.
- Open Access
- 26 August 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (8) , e0273433
Evaluating fomite risk of brown paper bags storing personal protective equipment exposed to SARS-CoV-2: A quasi-experimental study
Introduction: Literature is lacking on the safety of storing contaminated PPE in paper bags for reuse, potentially increasing exposure to frontline healthcare workers (HCW) and patients. The aim of this study is to evaluate the effectiveness of paper bags as a barrier for fomite transmission of SARS-CoV-2 by storing face masks, respirators, and face shields. Methods: This quasi-experimental study evaluated the presence of SARS-CoV-2 on the interior and exterior surfaces of paper bags containing PPE that had aerosolized exposures in clinical and simulated settings. Between May and October 2020, 30 unique PPE items were collected from COVID-19 units at two urban hospitals. Exposed PPE, worn by either an infected patient or HCW during a SARS-CoV-2 aerosolizing event, were placed into an unused paper bag. Samples were tested at 30-minute and 12-hour intervals. Results: A total of 177 swabs were processed from 30 PPE samples. We found a 6.8% positivity rate among all samples across both collection sites. Highest positivity rates were associated with ventilator disconnection and exposure to respiratory droplets from coughing. Positivity rates differed between hospital units. Total positivity rates were similar between 30-minute (6.7%) and 12-hour (6.9%) sample testing time intervals. Control samples exposed to inactivated SARS-CoV-2 droplets had higher total viral counts than samples exposed to nebulized aerosols. Conclusions: Data suggests paper bags are not a significant fomite risk for SARS-CoV-2 transmission. However, controls demonstrated a risk with droplet exposure. Data can inform guidelines for storing and re-using PPE in situations of limited supplies during future pandemics.
- 26 August 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (8) , e0273433
Open AccessEvaluating fomite risk of brown paper bags storing personal protective equipment exposed to SARS-CoV-2: A quasi-experimental study
Introduction: Literature is lacking on the safety of storing contaminated PPE in paper bags for reuse, potentially increasing exposure to frontline healthcare workers (HCW) and patients. The aim of this study is to evaluate the effectiveness of paper bags as a barrier for fomite transmission of SARS-CoV-2 by storing face masks, respirators, and face shields. Methods: This quasi-experimental study evaluated the presence of SARS-CoV-2 on the interior and exterior surfaces of paper bags containing PPE that had aerosolized exposures in clinical and simulated settings. Between May and October 2020, 30 unique PPE items were collected from COVID-19 units at two urban hospitals. Exposed PPE, worn by either an infected patient or HCW during a SARS-CoV-2 aerosolizing event, were placed into an unused paper bag. Samples were tested at 30-minute and 12-hour intervals. Results: A total of 177 swabs were processed from 30 PPE samples. We found a 6.8% positivity rate among all samples across both collection sites. Highest positivity rates were associated with ventilator disconnection and exposure to respiratory droplets from coughing. Positivity rates differed between hospital units. Total positivity rates were similar between 30-minute (6.7%) and 12-hour (6.9%) sample testing time intervals. Control samples exposed to inactivated SARS-CoV-2 droplets had higher total viral counts than samples exposed to nebulized aerosols. Conclusions: Data suggests paper bags are not a significant fomite risk for SARS-CoV-2 transmission. However, controls demonstrated a risk with droplet exposure. Data can inform guidelines for storing and re-using PPE in situations of limited supplies during future pandemics.
- 18 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2021, 742-752
A Simulation-Based Approach To Mitigate Disease Transmission Risk From Aerosol Particles In Buildings
Understanding the role of architectural design in identifying the risk of disease transmission is essential for creating resilience in buildings. Here we used a Grasshopper simulation workflow to execute aerosol disease transmission risk estimation coupled with EnergyPlus simulation inputs to assess the impact of architectural factors on the risk of COVID-19 transmission. We simulated the risk for a simple geometry with different window configurations and geographic locations. We observed that increasing the fractional opening of a single window as well as cross ventilation design can increase the outdoor air exchange, which corresponds to substantially reduced risk of disease transmission. Furthermore, indoor relative humidity in cold climates can be significantly lower in winter due to the impacts of increased mechanical heating which translates to an increased risk of infection. We demonstrate that early architectural design decisions implicate the resultant risk of disease transmission indoors that should be prioritized in the future.
- 18 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2021, 742-752
A Simulation-Based Approach To Mitigate Disease Transmission Risk From Aerosol Particles In Buildings
Understanding the role of architectural design in identifying the risk of disease transmission is essential for creating resilience in buildings. Here we used a Grasshopper simulation workflow to execute aerosol disease transmission risk estimation coupled with EnergyPlus simulation inputs to assess the impact of architectural factors on the risk of COVID-19 transmission. We simulated the risk for a simple geometry with different window configurations and geographic locations. We observed that increasing the fractional opening of a single window as well as cross ventilation design can increase the outdoor air exchange, which corresponds to substantially reduced risk of disease transmission. Furthermore, indoor relative humidity in cold climates can be significantly lower in winter due to the impacts of increased mechanical heating which translates to an increased risk of infection. We demonstrate that early architectural design decisions implicate the resultant risk of disease transmission indoors that should be prioritized in the future.
- Open Access
- 5 May 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-13
Longitudinal analysis of built environment and aerosol contamination associated with isolated COVID-19 positive individuals
The indoor environment is the primary location for the transmission of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the causative agent of coronavirus disease 2019 (COVID-19), largely driven by respiratory particle accumulation in the air and increased connectivity between the individuals occupying indoor spaces. In this study, we aimed to track a cohort of subjects as they occupied a COVID-19 isolation dormitory to better understand the impact of subject and environmental viral load over time, symptoms, and room ventilation on the detectable viral load within a single room. We find that subject samples demonstrate a decrease in overall viral load over time, symptoms significantly impact environmental viral load, and we provide the first real-world evidence for decreased aerosol SARS-CoV-2 load with increasing ventilation, both from mechanical and window sources. These results may guide environmental viral surveillance strategies and be used to better control the spread of SARS-CoV-2 within built environments and better protect those caring for individuals with COVID-19.
- 5 May 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-13
Open AccessLongitudinal analysis of built environment and aerosol contamination associated with isolated COVID-19 positive individuals
The indoor environment is the primary location for the transmission of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the causative agent of coronavirus disease 2019 (COVID-19), largely driven by respiratory particle accumulation in the air and increased connectivity between the individuals occupying indoor spaces. In this study, we aimed to track a cohort of subjects as they occupied a COVID-19 isolation dormitory to better understand the impact of subject and environmental viral load over time, symptoms, and room ventilation on the detectable viral load within a single room. We find that subject samples demonstrate a decrease in overall viral load over time, symptoms significantly impact environmental viral load, and we provide the first real-world evidence for decreased aerosol SARS-CoV-2 load with increasing ventilation, both from mechanical and window sources. These results may guide environmental viral surveillance strategies and be used to better control the spread of SARS-CoV-2 within built environments and better protect those caring for individuals with COVID-19.
- Open Access
- 11 March 2022
- Published by Springer Nature in Research Square
A novel VOC breath tracer method to evaluate indoor respiratory exposures in the near- and far-fields
Several studies suggest that far-field transmission (> 6 ft) explains the significant number of COVID-19 superspreading outbreaks. Therefore, quantitative evaluation of near- and far-field exposure to emissions from a source is key to better understanding human-to-human airborne infectious disease transmission and associated risks. In this study, we used an environmentally-controlled chamber to measure volatile organic compounds (VOCs) released from a healthy participant who consumed breath mints, which contained unique tracer compounds. Tracer measurements were made at 2.5 ft, 5 ft, 7.5 ft from the participant, as well as in the exhaust plenum of the chamber. We observed that 2.5 ft trials had substantially (~36-44%) higher concentrations than other distances during the first 20 minutes of experiments, highlighting the importance of the near-field relative to the far-field before virus-laden respiratory aerosol plumes are continuously mixed into the far-field. However, for the conditions studied, the concentrations of human-sourced tracers after 20 minutes and approaching the end of the 60-minute trials at 2.5 ft, 5 ft, and 7.5 ft were only ~18%, ~11%, and ~7.5% higher than volume-averaged concentrations, respectively. Our findings highlight the importance of far-field transmission of airborne pathogens including SARS-CoV-2, which need to be considered in public health decision making.
- 11 March 2022
- Published by Springer Nature in Research Square
Open AccessA novel VOC breath tracer method to evaluate indoor respiratory exposures in the near- and far-fields
Several studies suggest that far-field transmission (> 6 ft) explains the significant number of COVID-19 superspreading outbreaks. Therefore, quantitative evaluation of near- and far-field exposure to emissions from a source is key to better understanding human-to-human airborne infectious disease transmission and associated risks. In this study, we used an environmentally-controlled chamber to measure volatile organic compounds (VOCs) released from a healthy participant who consumed breath mints, which contained unique tracer compounds. Tracer measurements were made at 2.5 ft, 5 ft, 7.5 ft from the participant, as well as in the exhaust plenum of the chamber. We observed that 2.5 ft trials had substantially (~36-44%) higher concentrations than other distances during the first 20 minutes of experiments, highlighting the importance of the near-field relative to the far-field before virus-laden respiratory aerosol plumes are continuously mixed into the far-field. However, for the conditions studied, the concentrations of human-sourced tracers after 20 minutes and approaching the end of the 60-minute trials at 2.5 ft, 5 ft, and 7.5 ft were only ~18%, ~11%, and ~7.5% higher than volume-averaged concentrations, respectively. Our findings highlight the importance of far-field transmission of airborne pathogens including SARS-CoV-2, which need to be considered in public health decision making.
- Open Access
Evaluating Fomite Risk of Brown Paper Bags Storing Personal Protective Equipment Exposed to SARS-CoV-2: A Quasi-Experimental Study
Introduction Literature is lacking on the safety of storing contaminated PPE in paper bags for reuse, potentially increasing exposure to frontline healthcare workers (HCW) and patients. Objectives To evaluate the effectiveness of paper bags as a barrier for fomite transmission of SARS-CoV-2 by storing limited reusable face masks, respirators, and face shields. Methods This quasi-experimental study evaluated the presence of SARS-CoV-2 on the interior and exterior surfaces of paper bags containing PPE that had aerosolized exposures in clinical and simulated settings. Between May and October 2020, 30 unique PPE items were collected from critical and intermediate care COVID-19 units at two urban hospitals. Exposed PPE, worn by either an infected patient or HCW during a SARS-CoV-2 aerosolizing event, were placed into an unused brown paper bag. Samples were tested at 30-minute and 12-hour intervals. Results A total of 177 swabs were processed from 30 PPE samples. We found a (12/177 total) 6.8% positivity rate among all samples across both collection sites. Highest positivity rates were associated with ventilator disconnection (1/6 samples, 16.7% positivity) and exposure to respiratory droplets from coughing (2/24 samples, 8.3% positivity), compared to exposure to high-flow nasal cannula (8/129 samples, 6.2% positivity) or tracheostomy surgery (1/18 samples, 5.6% positivity). Positivity rates differed between hospital units. Total positivity rates were similar between 30-minute (6.7%) and 12-hour (6.9%) sample testing time intervals. Control samples exposed to inactivated SARS-CoV-2 droplets had higher total viral counts than samples exposed to nebulized aerosols. Conclusions Data suggests paper bags are not a significant fomite risk for SARS-CoV-2 transmission. However, controls demonstrated a risk with droplet exposure. Data can inform guidelines for storing and re-using PPE in situations of limited supplies during future pandemics.
Open AccessEvaluating Fomite Risk of Brown Paper Bags Storing Personal Protective Equipment Exposed to SARS-CoV-2: A Quasi-Experimental Study
Introduction Literature is lacking on the safety of storing contaminated PPE in paper bags for reuse, potentially increasing exposure to frontline healthcare workers (HCW) and patients. Objectives To evaluate the effectiveness of paper bags as a barrier for fomite transmission of SARS-CoV-2 by storing limited reusable face masks, respirators, and face shields. Methods This quasi-experimental study evaluated the presence of SARS-CoV-2 on the interior and exterior surfaces of paper bags containing PPE that had aerosolized exposures in clinical and simulated settings. Between May and October 2020, 30 unique PPE items were collected from critical and intermediate care COVID-19 units at two urban hospitals. Exposed PPE, worn by either an infected patient or HCW during a SARS-CoV-2 aerosolizing event, were placed into an unused brown paper bag. Samples were tested at 30-minute and 12-hour intervals. Results A total of 177 swabs were processed from 30 PPE samples. We found a (12/177 total) 6.8% positivity rate among all samples across both collection sites. Highest positivity rates were associated with ventilator disconnection (1/6 samples, 16.7% positivity) and exposure to respiratory droplets from coughing (2/24 samples, 8.3% positivity), compared to exposure to high-flow nasal cannula (8/129 samples, 6.2% positivity) or tracheostomy surgery (1/18 samples, 5.6% positivity). Positivity rates differed between hospital units. Total positivity rates were similar between 30-minute (6.7%) and 12-hour (6.9%) sample testing time intervals. Control samples exposed to inactivated SARS-CoV-2 droplets had higher total viral counts than samples exposed to nebulized aerosols. Conclusions Data suggests paper bags are not a significant fomite risk for SARS-CoV-2 transmission. However, controls demonstrated a risk with droplet exposure. Data can inform guidelines for storing and re-using PPE in situations of limited supplies during future pandemics.
- Open Access
- 6 January 2022
- Published by Oxford University Press (OUP) in Clinical Infectious Diseases
- Vol. 75 (1) , e174-e184
Quantifying Environmental Mitigation of Aerosol Viral Load in a Controlled Chamber With Participants Diagnosed With Coronavirus Disease 2019
Several studies indicate that coronavirus disease 2019 (COVID-19) is primarily transmitted within indoor spaces. Therefore, environmental characterization of severe acute respiratory syndrome coronavirus 2 viral load with respect to human activity, building parameters, and environmental mitigation strategies is critical to combat disease transmission. We recruited 11 participants diagnosed with COVID-19 to individually occupy a controlled chamber and conduct specified physical activities under a range of environmental conditions; we collected human and environmental samples over a period of 3 days for each participant. Here we show that increased viral load, measured by lower RNA cycle threshold (CT) values, in nasal samples is associated with higher viral loads in environmental aerosols and on surfaces captured in both the near field (1.2 m) and far field (3.5 m). We also found that aerosol viral load in far field is correlated with the number of particles within the range of 1–2.5 µm. Furthermore, we found that increased ventilation and filtration significantly reduced aerosol and surface viral loads, while higher relative humidity resulted in lower aerosol and higher surface viral load, consistent with an increased rate of particle deposition at higher relative humidity. Data from near field aerosol trials with high expiratory activities suggest that respiratory particles of smaller sizes (0.3–1 µm) best characterize the variance of near field aerosol viral load. Our findings indicate that building operation practices such as ventilation, filtration, and humidification substantially reduce the environmental aerosol viral load and therefore inhalation dose, and should be prioritized to improve building health and safety.
- 6 January 2022
- Published by Oxford University Press (OUP) in Clinical Infectious Diseases
- Vol. 75 (1) , e174-e184
Open AccessQuantifying Environmental Mitigation of Aerosol Viral Load in a Controlled Chamber With Participants Diagnosed With Coronavirus Disease 2019
Several studies indicate that coronavirus disease 2019 (COVID-19) is primarily transmitted within indoor spaces. Therefore, environmental characterization of severe acute respiratory syndrome coronavirus 2 viral load with respect to human activity, building parameters, and environmental mitigation strategies is critical to combat disease transmission. We recruited 11 participants diagnosed with COVID-19 to individually occupy a controlled chamber and conduct specified physical activities under a range of environmental conditions; we collected human and environmental samples over a period of 3 days for each participant. Here we show that increased viral load, measured by lower RNA cycle threshold (CT) values, in nasal samples is associated with higher viral loads in environmental aerosols and on surfaces captured in both the near field (1.2 m) and far field (3.5 m). We also found that aerosol viral load in far field is correlated with the number of particles within the range of 1–2.5 µm. Furthermore, we found that increased ventilation and filtration significantly reduced aerosol and surface viral loads, while higher relative humidity resulted in lower aerosol and higher surface viral load, consistent with an increased rate of particle deposition at higher relative humidity. Data from near field aerosol trials with high expiratory activities suggest that respiratory particles of smaller sizes (0.3–1 µm) best characterize the variance of near field aerosol viral load. Our findings indicate that building operation practices such as ventilation, filtration, and humidification substantially reduce the environmental aerosol viral load and therefore inhalation dose, and should be prioritized to improve building health and safety.
- Open Access
- 15 November 2021
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 16 (11) , e0257689
Evaluation of a bioaerosol sampler for indoor environmental surveillance of Severe Acute Respiratory Syndrome Coronavirus 2
The worldwide spread of Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) has ubiquitously impacted many aspects of life. As vaccines continue to be manufactured and administered, limiting the spread of SARS-CoV-2 will rely more heavily on the early identification of contagious individuals occupying reopened and increasingly populated indoor environments. In this study, we investigated the utility of an impaction-based bioaerosol sampling system with multiple nucleic acid collection media. Heat-inactivated SARS-CoV-2 was utilized to perform bench-scale, short-range aerosol, and room-scale aerosol experiments. Through bench-scale experiments, AerosolSense Capture Media (ACM) and nylon flocked swabs were identified as the highest utility media. In room-scale aerosol experiments, consistent detection of aerosol SARS-CoV-2 was achieved at an estimated aerosol concentration equal to or greater than 0.089 genome copies per liter of room air (gc/L) when air was sampled for eight hours or more at less than one air change per hour (ACH). Shorter sampling periods (75 minutes) yielded consistent detection at ~31.8 gc/L of room air and intermittent detection down to ~0.318 gc/L at (at both 1 and 6 ACH). These results support further exploration in real-world testing scenarios and suggest the utility of indoor aerosol surveillance as an effective risk mitigation strategy in occupied buildings.
- 15 November 2021
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 16 (11) , e0257689
Open AccessEvaluation of a bioaerosol sampler for indoor environmental surveillance of Severe Acute Respiratory Syndrome Coronavirus 2
The worldwide spread of Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) has ubiquitously impacted many aspects of life. As vaccines continue to be manufactured and administered, limiting the spread of SARS-CoV-2 will rely more heavily on the early identification of contagious individuals occupying reopened and increasingly populated indoor environments. In this study, we investigated the utility of an impaction-based bioaerosol sampling system with multiple nucleic acid collection media. Heat-inactivated SARS-CoV-2 was utilized to perform bench-scale, short-range aerosol, and room-scale aerosol experiments. Through bench-scale experiments, AerosolSense Capture Media (ACM) and nylon flocked swabs were identified as the highest utility media. In room-scale aerosol experiments, consistent detection of aerosol SARS-CoV-2 was achieved at an estimated aerosol concentration equal to or greater than 0.089 genome copies per liter of room air (gc/L) when air was sampled for eight hours or more at less than one air change per hour (ACH). Shorter sampling periods (75 minutes) yielded consistent detection at ~31.8 gc/L of room air and intermittent detection down to ~0.318 gc/L at (at both 1 and 6 ACH). These results support further exploration in real-world testing scenarios and suggest the utility of indoor aerosol surveillance as an effective risk mitigation strategy in occupied buildings.
- Open Access
- 28 October 2021
- Published by Wiley in Risk Analysis
- Vol. 42 (9) , 2075-2088
A Quantitative Risk Estimation Platform for Indoor Aerosol Transmission of COVID‐19
Aerosol transmission has played a significant role in the transmission of COVID‐19 disease worldwide. We developed a COVID‐19 aerosol transmission risk estimation model to better understand how key parameters associated with indoor spaces and infector emissions affect inhaled deposited dose of aerosol particles that convey the SARS‐CoV‐2 virus. The model calculates the concentration of size‐resolved, virus‐laden aerosol particles in well‐mixed indoor air challenged by emissions from an index case(s). The model uses a mechanistic approach, accounting for particle emission dynamics, particle deposition to indoor surfaces, ventilation rate, and single‐zone filtration. The novelty of this model relates to the concept of “inhaled & deposited dose” in the respiratory system of receptors linked to a dose–response curve for human coronavirus HCoV‐229E. We estimated the volume of inhaled & deposited dose of particles in the 0.5–4 μm range expressed in picoliters (pL) in a well‐documented COVID‐19 outbreak in restaurant X in Guangzhou China. We anchored the attack rate with the dose–response curve of HCoV‐229E which provides a preliminary estimate of the average SARS‐CoV‐2 dose per person, expressed in plaque forming units (PFUs). For a reasonable emission scenario, we estimate approximately three PFU per pL deposited, yielding roughly 10 PFUs deposited in the respiratory system of those infected in restaurant X. To explore the model's utility, we tested it with four COVID‐19 outbreaks. The risk estimates from the model fit reasonably well with the reported number of confirmed cases given available metadata from the outbreaks and uncertainties associated with model assumptions.
- 28 October 2021
- Published by Wiley in Risk Analysis
- Vol. 42 (9) , 2075-2088
Open AccessA Quantitative Risk Estimation Platform for Indoor Aerosol Transmission of COVID‐19
Aerosol transmission has played a significant role in the transmission of COVID‐19 disease worldwide. We developed a COVID‐19 aerosol transmission risk estimation model to better understand how key parameters associated with indoor spaces and infector emissions affect inhaled deposited dose of aerosol particles that convey the SARS‐CoV‐2 virus. The model calculates the concentration of size‐resolved, virus‐laden aerosol particles in well‐mixed indoor air challenged by emissions from an index case(s). The model uses a mechanistic approach, accounting for particle emission dynamics, particle deposition to indoor surfaces, ventilation rate, and single‐zone filtration. The novelty of this model relates to the concept of “inhaled & deposited dose” in the respiratory system of receptors linked to a dose–response curve for human coronavirus HCoV‐229E. We estimated the volume of inhaled & deposited dose of particles in the 0.5–4 μm range expressed in picoliters (pL) in a well‐documented COVID‐19 outbreak in restaurant X in Guangzhou China. We anchored the attack rate with the dose–response curve of HCoV‐229E which provides a preliminary estimate of the average SARS‐CoV‐2 dose per person, expressed in plaque forming units (PFUs). For a reasonable emission scenario, we estimate approximately three PFU per pL deposited, yielding roughly 10 PFUs deposited in the respiratory system of those infected in restaurant X. To explore the model's utility, we tested it with four COVID‐19 outbreaks. The risk estimates from the model fit reasonably well with the reported number of confirmed cases given available metadata from the outbreaks and uncertainties associated with model assumptions.