Ultra-low limit of detection of a carcinoembryonic antigen fiber sensor based on microfiber
- 5 May 2025
- journal article
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 16 (6) , 2232-2242
Abstract
Fiber optic sensors have been widely applied to address issues such as cardiovascular diseases, pathogen detection, and cancer biomarker detection. In this work, an ultra-low limit of detection, high-specificity, and label-free optical fiber biosensor for the detection of carcinoembryonic antigen (CEA) was proposed and experimentally demonstrated. A microfiber interferometer with refractive index sensitivity of up to 1915.955 nm/RIU was employed as the sensor head. The sensitivity of the sensor was further enhanced by the incorporation of molybdenum disulfide (MoS2), which facilitated the immobilization of CEA antibodies as specific detection markers on the microfiber surface. Experimental results showed that the proposed sensor achieved a detection limit of 15.86 fg/mL. The sensitivity of the biosensor was 4.727 nm/log(mg/mL). Notably, this biosensor demonstrated excellent specificity and label-free operation and enabled the detection of low-concentration CEA in approximately 15 minutes. The proposed micro fiber CEA sensor provided a highly sensitive and low-cost method for the early diagnosis of cancer.Keywords
Funding Information
- Sichuan Science and Technology Program (2023NSFSC0033, 2023NSFSC1964)
This publication has 28 references indexed in Scilit:
- Global cancer statistics 2022Cancer, 2024
- Research on efficient braille recognition based on the pair-U-shaped micro-nano optical fiber fingerprint-like tactile sensorsOptics & Laser Technology, 2024
- Clinical value of seven autoantibodies combined detection in the diagnosis of lung cancerJournal of Clinical Laboratory Analysis, 2020
- Electrochemical detection of carcinoembryonic antigenBiosensors and Bioelectronics, 2018
- Multiplexed detection of lung cancer biomarkers in patients serum with CMOS-compatible silicon nanowire arraysBiosensors and Bioelectronics, 2017
- Label-free fluorimetric detection of CEA using carbon dots derived from tomato juiceBiosensors and Bioelectronics, 2016
- Detection of carcinoembryonic antigen using single-domain or full-size antibodies stained with quantum dot conjugatesAnalytical Biochemistry, 2015
- Biomolecular recognition with a sensitivity-enhanced nanowire transistor biosensorBiosensors and Bioelectronics, 2013
- The role of carcinoembryonic antigen monitoring in management of colorectal cancerCurrent Oncology Reports, 1999
- Diagnostic value of CA 72-4, carcinoembryonic antigen, CA 15-3, and CA 19-9 assay in pleural fluid: A study of 207 patientsCancer, 1996