Vibration signature analysis for rotor broken bar diagnosis in double cage induction motor drives
- 1 May 2013
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21555516,p. 1814-1820
Abstract
The paper investigates the diagnosis of rotor broken bars in field oriented controlled (FOC) double cage induction motor drives, using current and vibration signature analysis techniques. The Impact of the closed loop control system cannot be neglected when the detection of asymmetries in the machine are based on the signature analysis of electrical variables. The proposed diagnosis approach is based on optimized use of wavelet analysis by a pre-processing of phase current or axial/radial vibration signals. Thus, the time evolution of the tracked rotor fault components can be effectively analyzed. This paper shows also the relevance of the fault components computed from axial vibration signal in comparison to those coming from phase current and radial vibration signals. Cyclic fault quantification, issued from the wavelet analysis, has been introduced for accurate rotor fault detection. Experimental results show the validity of the proposed technique, leading to an effective diagnosis procedure for rotor broken bar in double cage induction motor.Keywords
This publication has 32 references indexed in Scilit:
- Analytical Investigation and Control System Set-up of Medium Scale PV Plants for Power Flow ManagementEnergies, 2012
- A geometrical simple approach for power silicon devices fault detection and fault-tolerant operation of a voltage source inverter2012
- Main Fuel Cells mathematical models: Comparison and analysis in terms of free parameters2010
- FPGA implementation of a fuel cell emulator2010
- Integrated mathematical model of proton exchange membrane fuel cell stack (PEMFC) with automotive synchronous electrical power drive2008
- A fuel cell-based hybrid power supply for portable electronics devices2008
- Diagnosis of Rotor Faults in Closed-Loop Induction Motor Drives2007 IEEE Industry Applications Annual Meeting, 2006
- Flux signature analysis: An alternative method for the fault diagnosis of induction machines2005
- The Vienna induction machine monitoring method; on the impact of the field oriented control structure on real operational behavior of a faulty machine2002
- Closed-loop control impact on the diagnosis of induction motors faultsIEEE Transactions on Industry Applications, 2000