Can surface topography reliably determine the Rigo classification system?
- 15 January 2025
- journal article
- research article
- Published by Springer Nature in European Spine Journal
- Vol. 34 (2) , 565-571
Abstract
Purpose No studies have explored the reliability of the Rigo classification system using surface topography (ST), which would allow optimization without radiation exposure. This study aims to measure and compare the intra- and inter-observer reliability (Kappa values) and accuracy of the Rigo system between ST and X-ray for overall types and subtypes. Methods X-ray and ST images of 31 adolescent idiopathic scoliosis patients were selected. Three investigators were blinded to assess images using the Rigo system, twice for each patient on different weeks, with 372 overall image readings. Afterwards, all investigators agreed upon the correct Rigo scores for finalized classifications. Results For Rigo types, the average intra-observer Kappa value was slightly better for ST (0.77, p<0.001) than X-ray (0.75, p<0.001). For Rigo subtypes, the average intra-observer Kappa value was again slightly better for ST (0.74, p<0.001) than X-ray (0.65, p<0.001). The inter-observer reliability was expectedly lower than intra-observer, with ST (0.53, p<0.001) comparable to X-ray (0.54, p<0.001) for the type. For subtype inter-observer reliability, ST (0.43, p<0.001) was slightly better than X-ray (0.36, p<0.001). For the type, the overall accuracy of the observers was slightly lower for ST (77.96%) than X-ray (79.57%). For the subtype, the accuracy of observers was slightly higher for ST (70.97%) than X-ray (65.05%). Conclusion ST-based Rigo system demonstrates very good intra-rater reproducibility and moderately good inter-rater reproducibility. Surface topography is comparable to X-ray for the Rigo system, and therefore can be considered a reliable alternative in clinical application.Keywords
This publication has 16 references indexed in Scilit:
- The reliability of the augmented Lehnert-Schroth and Rigo classification in scoliosis managementSouth African Journal of Physiotherapy, 2021
- Cancer and mortality risks of patients with scoliosis from radiation exposure: a systematic review and meta-analysisEuropean Spine Journal, 2020
- Cost and Clinical Outcome of Adolescent Idiopathic Scoliosis Surgeries—Experience From a Nonprofit Community HospitalInternational Journal of Spine Surgery, 2019
- Classifications in Brief: The Lenke Classification for Adolescent Idiopathic ScoliosisClinical Orthopaedics and Related Research, 2018
- Imaging in the Diagnosis and Monitoring of Children with Idiopathic ScoliosisThe Open Orthopaedics Journal, 2017
- Comparison of the DIERS Formetric 4D Scanner and Plain Radiographs in Terms of Accuracy in Idiopathic Scoliosis PatientsGlobal Spine Journal, 2016
- Management decisions for adolescent idiopathic scoliosis significantly affect patient radiation exposureThe Spine Journal, 2014
- Comparison of Radiographic and Surface Topography Measurements in Adolescents with Idiopathic ScoliosisThe Open Orthopaedics Journal, 2012
- Quality Control of Idiopathic Scoliosis Treatment in 147 Patients While Using the RSC® BraceJPO Journal of Prosthetics and Orthotics, 2011
- A specific scoliosis classification correlating with brace treatment: description and reliabilityScoliosis and Spinal Disorders, 2010