    Radiological and Surface Topography Criteria: A Comparative Study Within the Rigo Classification

    by Natalie Schmidt, Adam Thiessen, Marissa Selthafner, Kai Yang, Xue-Cheng Liu

    Background/Objectives: No descriptive data have been reported for the radiological criteria used in the Rigo classification system (RCS) beyond the curve pattern. This study aims to quantify, compare, and correlate the criteria using X-ray and surface topography (ST). Methods: Three observers classified ST and X-ray AIS images according to the RCS. One observer then measured the following RCS criteria on both ST and X-ray, twice for each image, and averaged the measurements: Cobb angle, T1 offset, T1 tilt, transition point (TP) offset, L3 tilt, L4 tilt, L5 tilt, and pelvic shift. Results: Between ST and X-ray, the TP offset showed no significant differences (p > 0.05) and very strong correlation (r = 0.90, p < 0.0001). T1 offset and pelvic shift had no significant differences between ST and X-ray (p > 0.05) and had moderate to strong correlation (r = 0.59 to 0.73, p < 0.001). The Cobb angle showed moderate correlation for all types (r = 0.67, p < 0.0001), but showed significant difference for the B and E types. All other criteria demonstrated strong to very strong correlation between ST and X-ray (r = 0.76 to 0.90, p < 0.05), except for T1 tilt. Significant differences existed between ST and X-ray for the following criteria and types: T1 tilt (B, C); L3 tilt (B, E); L4 tilt (A, B); and L5 tilt (A). All ST criteria demonstrated moderate to good agreement (ICC = 0.57 to 0.88, p < 0.001), except T1 tilt (ICC = 0.14). Conclusions: Both ST and X-ray provide several valuable RCS criteria, with TP offset, T1 offset, and pelvic shift showing no significant differences between imaging systems. These ST-based parameters may provide complementary value to traditional radiological criteria within the RCS framework.

  • Can surface topography reliably determine the Rigo classification system?

    by Natalie Schmidt, Adam Thiessen, Marissa Selthafner, Xue-Cheng Liu

    Purpose No studies have explored the reliability of the Rigo classification system using surface topography (ST), which would allow optimization without radiation exposure. This study aims to measure and compare the intra- and inter-observer reliability (Kappa values) and accuracy of the Rigo system between ST and X-ray for overall types and subtypes. Methods X-ray and ST images of 31 adolescent idiopathic scoliosis patients were selected. Three investigators were blinded to assess images using the Rigo system, twice for each patient on different weeks, with 372 overall image readings. Afterwards, all investigators agreed upon the correct Rigo scores for finalized classifications. Results For Rigo types, the average intra-observer Kappa value was slightly better for ST (0.77, p<0.001) than X-ray (0.75, p<0.001). For Rigo subtypes, the average intra-observer Kappa value was again slightly better for ST (0.74, p<0.001) than X-ray (0.65, p<0.001). The inter-observer reliability was expectedly lower than intra-observer, with ST (0.53, p<0.001) comparable to X-ray (0.54, p<0.001) for the type. For subtype inter-observer reliability, ST (0.43, p<0.001) was slightly better than X-ray (0.36, p<0.001). For the type, the overall accuracy of the observers was slightly lower for ST (77.96%) than X-ray (79.57%). For the subtype, the accuracy of observers was slightly higher for ST (70.97%) than X-ray (65.05%). Conclusion ST-based Rigo system demonstrates very good intra-rater reproducibility and moderately good inter-rater reproducibility. Surface topography is comparable to X-ray for the Rigo system, and therefore can be considered a reliable alternative in clinical application.