A plano–convex thick-lens velocity map imaging apparatus for direct, high resolution 3D momentum measurements of photoelectrons with ion time-of-flight coincidence
Authors:
- Michael DavinoMDMichael Davino
- Edward McManusEMEdward McManus
- Nora G. HelmingNHNora G. Helming
- Chuan ChengCCChuan Cheng
- Gönenç MoǧolGMGönenç Moǧol
- Zhanna RodnovaZRZhanna Rodnova
- Geoffrey HarrisonGHGeoffrey Harrison
- Thomas WeinachtTWThomas Weinacht
- George N. GibsonGGGeorge N. Gibson
- Tobias SauleTSTobias Saule
- Carlos A. Trallero-HerreroCTCarlos A. Trallero-Herrero
Open Access
- 1 January 2023
- journal article
- research article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (1) , 013303
Abstract
Since their inception, velocity map imaging (VMI) techniques have received continued interest in their expansion from 2D to 3D momentum measurements through either reconstructive or direct methods. Recently, much work has been devoted to the latter of these by relating electron time-of-flight (TOF) to the third momentum component. The challenge is having a timing resolution sufficient to resolve the structure in the narrow (<10 ns) electron TOF spread. Here, we build upon the work in VMI lens design and 3D VMI measurement by using a plano–convex thick-lens (PCTL) VMI in conjunction with an event-driven camera (TPX3CAM) providing TOF information for high resolution 3D electron momentum measurements. We perform simulations to show that, with the addition of a mesh electrode to the thick-lens geometry, the resulting plano–convex electrostatic field extends the detectable electron cutoff energy range while retaining the high resolution. This design also extends the electron TOF range, allowing for a better momentum resolution along this axis. We experimentally demonstrate these capabilities by examining above-threshold ionization in xenon, where the apparatus is shown to collect electrons of energy up to ∼7 eV with a TOF spread of ∼30 ns, both of which are improved compared to a previous work by factors of ∼1.4 and ∼3.75, respectively. Finally, the PCTL-VMI is equipped with a coincident ion TOF spectrometer, which is shown to effectively extract unique 3D momentum distributions for different ionic species in a gas mixture. These techniques have the potential to lend themselves to more advanced measurements involving systems where the electron momentum distributions possess non-trivial symmetries.Keywords
All Related Versions
Funding Information
- Air Force Office of Scientific Research (FA9550-21-1-0387)
- U.S. Department of Energy (DE-SC0019098, DEF-G02-08ER15983)
This publication has 32 references indexed in Scilit:
- DELICIOUS III: A multipurpose double imaging particle coincidence spectrometer for gas phase vacuum ultraviolet photodynamics studiesReview of Scientific Instruments, 2013
- Molecular-Frame 3D Photoelectron Momentum Distributions by Tomographic ReconstructionPhysical Review Letters, 2012
- Momentum spectra of electrons rescattered from rare-gas targets following their extraction by one- and two-color femtosecond laser pulsesPhysical Review A, 2011
- Momentum space tomographic imaging of photoelectronsJournal of Physics B: Atomic, Molecular and Optical Physics, 2009
- Three-dimensional velocity map imaging: Setup and resolution improvement compared to three-dimensional ion imagingReview of Scientific Instruments, 2009
- Recoil-ion and electron momentum spectroscopy: reaction-microscopesReports on Progress in Physics, 2003
- Application of time-sliced ion velocity imaging to crossed molecular beam experimentsReview of Scientific Instruments, 2003
- Cold Target Recoil Ion Momentum Spectroscopy: a ‘momentum microscope’ to view atomic collision dynamicsPhysics Reports, 2000
- Recoil-ion momentum spectroscopyJournal of Physics B: Atomic, Molecular and Optical Physics, 1997
- Reconstruction of an axisymmetric image from its blurred and noisy projectionApplied Optics, 1991