GGGeorge N. Gibson

George N. Gibson

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


George N. Gibson has a total of 42 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Grating-coupled fluorescent plasmonic (GC-FP) biosensor for point-of-care serological detection of Lyme Disease

    by Dwiti Krushna Das, Benjamin Taubner, Jacob Pelton, William Page, Arturo Pilar, George Gibson, Klemen Strle, Nathaniel Cady

  • Open Access

    Single photon zeptosecond interferometry

    by Geoffrey R Harrison, Tobias Saule, R Esteban Goetz, George N Gibson, Camilo Granados, Bikash K Das, Marcelo F Ciappina, Anh-Thu Le, Carlos A Trallero-Herrero

    We demonstrate the generation of a train of attosecond XUV pulses that are in a superposition of wavefront states. Such superposition yields a high precision, self-referencing, common path XUV interferometer setup to produce pairs of spatially separated and independently controllable XUV pulses that are locked in phase and time with a temporal jitter of 3.5 zs (zs = zeptoseconds = 10 − 21 s ). In our approach, we can independently control the relative phase/delay of the two optical beams with a resolution of 52 zs. Since the jitter is on the order of the Compton time scale τ C = λ C / m e c 2 , we explore the level of correlation between the non-local photons by comparing different spatial mode superpositions. Further, thanks to the stability of the interferometer we can retrieve the interference pattern through photon counting. Through post-selection of different particle events we can analyze one, two or more photon events. We argue that this zeptosecond level of temporal precision will open the door for new dynamical quantum electrodynamics (QED) tests at lower intensities while photon counting experiments can also have an impact on the emerging field of quantum light in strong fields. We also discuss the potential impact on other areas, such as time-dependent QED, imaging, measurements of non-locality, and molecular quantum tomography.

  • Open Access

    Grating-Coupled Fluorescent Plasmonic (GC-FP) Biosensor for Point-of-Care Serological Detection of Lyme Disease

    by Dwiti Krushna Das, Benjamin Taubner, Jacob Pelton, William D. Page, Arturo Pilar, George N. Gibson, Klemen Strle, Nathaniel C. Cady

    Timely and accurate diagnosis of Lyme disease (LD) remains limited by complicated serological testing, which requires specialized laboratory equipment and has a multi-day turnaround, thereby limiting its utility in point-of-care (POC) settings. We have previously demonstrated a grating-coupled fluorescent plasmonic (GC-FP) biosensor in a microfluidics-based format (MF) for serological detection of LD. In this work, we demonstrate translation of an MF to a simplified dipstick assay. The assay utilizes miniaturized 4×4 mm gold-coated chips with a nanoscale grating that enhances fluorescence through surface plasmon-coupled emission (SPCE). The unique dipstick-based (DS) workflow eliminates the need for microfluidic pumps and complex instrumentation and has a total assay time of 24 min. The dipstick format integrates both tiers of the standard two-tiered diagnostic algorithm on a single chip, enabling simultaneous detection of first-tier screening antigen C6 and second-tier confirmatory antigens VlsE, DbpA, and DbpB. Validation was performed using thirty human serum samples tested in DS GC-FP chips, MF GC-FP chips, and a commercially available FDA-cleared LD diagnostic assay (ZEUS Borrelia MTTT®). All thirty human samples were correctly classified across all platforms, yielding 100% agreement in final diagnostic outcomes. The dipstick format substantially reduces equipment requirements, material costs, and operational complexity while preserving diagnostic accuracy, making it well-suited for deployment in urgent care centers, physician offices, and resource-limited settings.

  • Voltage-induced modulation of interfacial ionic liquids measured using surface plasmon resonant grating nanostructures

    by Indu Aravind, Yu Wang, Zhi Cai, Ruoxi Li, Rifat Shahriar, George N. Gibson, Ernest Guignon, Nathaniel C. Cady, William D. Page, Arturo Pilar, et al.

    We have used surface plasmon resonant metal gratings to induce and probe the dielectric response (i.e., electro-optic modulation) of ionic liquids (ILs) at electrode interfaces. Here, the cross-plane electric field at the electrode surface modulates the refractive index of the IL due to the Pockels effect. This is observed as a shift in the resonant angle of the grating (i.e., Δϕ), which can be related to the change in the local index of refraction of the electrolyte (i.e., Δnlocal). The reflection modulation of the IL is compared against a polar (D2O) and a non-polar solvent (benzene) to confirm the electro-optic origin of resonance shift. The electrostatic accumulation of ions from the IL induces local index changes to the gratings over the extent of electrical double layer (EDL) thickness. Finite difference time domain simulations are used to relate the observed shifts in the plasmon resonance and change in reflection to the change in the local index of refraction of the electrolyte and the thickness of the EDL. Simultaneously using the wavelength and intensity shift of the resonance enables us to determine both the effective thickness and Δn of the double layer. We believe that this technique can be used more broadly, allowing the dynamics associated with the potential-induced ordering and rearrangement of ionic species in electrode–solution interfaces.


  • Open Access

    A plano–convex thick-lens velocity map imaging apparatus for direct, high resolution 3D momentum measurements of photoelectrons with ion time-of-flight coincidence

    by Michael Davino, Edward McManus, Nora G. Helming, Chuan Cheng, Gönenç Moǧol, Zhanna Rodnova, Geoffrey Harrison, Kevin Watson, Thomas Weinacht, George N. Gibson, et al.

    Since their inception, velocity map imaging (VMI) techniques have received continued interest in their expansion from 2D to 3D momentum measurements through either reconstructive or direct methods. Recently, much work has been devoted to the latter of these by relating electron time-of-flight (TOF) to the third momentum component. The challenge is having a timing resolution sufficient to resolve the structure in the narrow (<10 ns) electron TOF spread. Here, we build upon the work in VMI lens design and 3D VMI measurement by using a plano–convex thick-lens (PCTL) VMI in conjunction with an event-driven camera (TPX3CAM) providing TOF information for high resolution 3D electron momentum measurements. We perform simulations to show that, with the addition of a mesh electrode to the thick-lens geometry, the resulting plano–convex electrostatic field extends the detectable electron cutoff energy range while retaining the high resolution. This design also extends the electron TOF range, allowing for a better momentum resolution along this axis. We experimentally demonstrate these capabilities by examining above-threshold ionization in xenon, where the apparatus is shown to collect electrons of energy up to ∼7 eV with a TOF spread of ∼30 ns, both of which are improved compared to a previous work by factors of ∼1.4 and ∼3.75, respectively. Finally, the PCTL-VMI is equipped with a coincident ion TOF spectrometer, which is shown to effectively extract unique 3D momentum distributions for different ionic species in a gas mixture. These techniques have the potential to lend themselves to more advanced measurements involving systems where the electron momentum distributions possess non-trivial symmetries.


  • Open Access

    Toward an ultrafast double-pulse stretcher–compressor

    by Soroush D. Khosravi, Marco Scipioni, George N. Gibson

    The design of an ultrafast double-pulse stretcher–compressor, which can be utilized in applications like Raman chirped adiabatic passage experiments, is presented. Experimental PG FROG traces obtained for a single-pulse output of such a stretcher–compressor support the design. However, the FROG traces of a double-pulse output are not intuitive and not fully retrievable. Therefore, a code was developed to simulate these FROG traces and investigate their dependence on the delay between the two slices of the double-pulse. The results are presented here and can be employed as a diagnostic tool in different applications where ultrafast laser double-pulses are used. The simulations reveal that the FROG traces strongly depend on the delay between the two slices of the double-pulse when this delay is comparable to the pulse duration. The simulations also suggest that using a transform-limited single-pulse as the gate in the PG FROG instrument leads to simpler FROG traces.


  • Open Access

    Production and Study of Triply Charged Diatomic Ions with Femtosecond Pulses: Application to

    by R. J. Verver, D. R. Matusek, J. S. Wright, G. N. Gibson, R. Bhardwaj, S. Aseyev, D. M. Villeneuve, P. B. Corkum, M. Yu. Ivanov