Quantification of Collagen Ultrastructure after Penetrating Keratoplasty – Implications for Corneal Biomechanics
Open Access
- 5 July 2013
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 8 (7) , e68166
Abstract
To quantify long-term changes in stromal collagen ultrastructure following penetrating keratoplasty (PK), and evaluate their possible implications for corneal biomechanics. A pair of 16 mm post-mortem corneo-scleral buttons was obtained from a patient receiving bilateral penetrating keratoplasty 12 (left)/28 (right) years previously. Small-angle x-ray scattering quantified collagen fibril spacing, diameter and spatial order at 0.5 mm or 0.25 mm intervals along linear scans across the graft margin. Corresponding control data was collected from two corneo-scleral buttons with no history of refractive surgery. Wide-angle x-ray scattering quantified collagen fibril orientation at 0.25 mm (horizontal)×0.25 mm (vertical) intervals across both PK specimens. Quantification of orientation changes in the graft margin were verified by equivalent analysis of data from a 13 year post-operative right PK specimen obtained from a second patient in a previous study, and comparison made with new and published data from normal corneas. Marked changes to normal fibril alignment, in favour of tangentially oriented collagen, were observed around the entire graft margin in all PK specimens. The total number of meridional fibrils in the wound margin was observed to decrease by up to 40%, with the number of tangentially oriented fibrils increasing by up to 46%. As a result, in some locations the number of fibrils aligned parallel to the wound outnumbered those spanning it by up to five times. Localised increases in fibril spacing and diameter, with an accompanying reduction in matrix order, were also evident. Abnormal collagen fibril size and spatial order within the PK graft margin are indicative of incomplete stromal wound remodelling and the long term persistence of fibrotic scar tissue. Lasting changes in collagen fibril orientation in and around PK wounds may alter corneal biomechanics and compromise the integrity of the graft-host interface in the long term.Keywords
This publication has 35 references indexed in Scilit:
- Quantitative Assessment of Ultrastructure and Light Scatter in Mouse Corneal Debridement WoundsInvestigative Ophthalmology & Visual Science, 2012
- Quantification of Collagen Organization in the Peripheral Human Cornea at Micron-Scale ResolutionBiophysical Journal, 2011
- 3D Collagen Orientation Study of the Human Cornea Using X-ray Diffraction and Femtosecond Laser TechnologyInvestigative Ophthalmology & Visual Science, 2009
- The use of X-ray scattering techniques to quantify the orientation and distribution of collagen in the corneal stromaProgress in Retinal and Eye Research, 2009
- A structural investigation of corneal graft failure in suspected recurrent keratoconusEye, 2009
- Full-field deformation of bovine cornea under constrained inflation conditionsBiomaterials, 2008
- Extended Long-term Outcomes of Penetrating Keratoplasty for KeratoconusOphthalmology, 2006
- X-Ray Scattering Used to Map the Preferred Collagen Orientation in the Human Cornea and LimbusStructure, 2004
- Corneal scar formationExperimental Eye Research, 1973
- BILATERAL PERIPHERAL SCLERO‐CORNEAActa Ophthalmologica, 1969