Physical Activity of ICU Survivors during Acute Admission: Agreement of the activPAL with Observation
- 1 February 2018
- journal article
- research article
- Published by University of Toronto Press Inc. (UTPress) in Physiotherapy Canada
- Vol. 70 (1) , 57-63
Abstract
Purpose: We estimated the agreement of a thigh-worn accelerometer, the activPAL, used to measure activity and sedentary parameters, with observed mobility assessments of intensive care unit (ICU) survivors. Method: We prospectively compared activPAL measurements with direct observation during assessments at discharge from the ICU or acute hospital in eight participants with a median age of 56 (1st–3rd quartile 48–65) years and an Acute Physiology and Chronic Health Evaluation II score of 23 (1st–3rd quartile 17–24). Frequency of sit-to-stand transitions; time spent standing, stepping, upright (standing and stepping), and sedentary (lying/sitting); and total steps were described; analysis was performed using Bland–Altman plots and calculating the absolute percent error. Results: All sit-to-stand transitions were accurately detected. The mean difference on the Bland–Altman plots suggested an overestimation of standing time with the activPAL of 31 (95% CI: −9, 71) seconds and underestimation of stepping time by 25 (95% CI: −47, −3) seconds. The largest median absolute percent errors were for standing time (21.9%) and stepping time (18.7%); time spent upright (1.7%) or sedentary (0.3%) was more accurately estimated. The activPAL underestimated total steps per session, achieving the largest percent error (70.8%). Conclusion: Because it underestimated step count, the activPAL likely incorrectly recorded stepping time as standing time, so that time spent upright was the measure of activity with the smallest error. Sedentary behaviour, including frequency of transitions, was validly assessed.Keywords
This publication has 17 references indexed in Scilit:
- Accuracy of Posture Allocation Algorithms for Thigh- and Waist-Worn AccelerometersMedicine & Science in Sports & Exercise, 2016
- Physical activity, muscle strength, and exercise capacity 3 months after severe sepsis and septic shockIntensive Care Medicine, 2015
- Measuring Activity Levels at an Acute Stroke Ward: Comparing Observations to a DeviceBioMed Research International, 2013
- The Influence of Minimum Sitting Period of the ActivPAL™ on the Measurement of Breaks in Sitting in Young ChildrenPLOS ONE, 2013
- Physiotherapists systematically overestimate the amount of time stroke survivors spend engaged in active therapy rehabilitation: an observational studyJournal of Physiotherapy, 2013
- Can an Accelerometer-Based Monitor be used to Accurately Assess Physical Activity in a Population of Survivors of Critical Illness?Global Journal of Health Science, 2012
- Accuracy and responsiveness of the stepwatch activity monitor and ActivPAL in patients with COPD when walking with and without a rollatorDisability and Rehabilitation, 2011
- Evaluation of a Body-Worn Sensor System to Measure Physical Activity in Older People With Impaired FunctionPhysical Therapy, 2011
- Observation of Amounts of Movement Practice Provided During Stroke RehabilitationArchives of Physical Medicine and Rehabilitation, 2009
- Validation of use of wireless monitors to measure levels of mobility during hospitalizationJournal of Rehabilitation Research and Development, 2008