Modelling of detective quantum efficiency of direct conversion x-ray imaging detectors incorporating charge carrier trapping and K -fluorescence
Authors:
- 20 May 2011
- journal article
- research article
- Published by Institution of Engineering and Technology (IET) in IET Circuits, Devices & Systems
- Vol. 5 (3) , 222-231
Abstract
A cascaded linear system model is developed for calculating the frequency-dependent detective quantum efficiency, DQE(f), of a direct conversion x-ray imaging detector by incorporating the effects of charge carrier trapping and reabsorption of K-fluorescent x-rays. The present model considers a combination of series and parallel processes and interactions between them. The modulation transfer function for K-fluorescent x-ray reabsorption is modelled by determining the line spread function and subsequent one-dimensional Fourier transform. The DQE model is applied to amorphous selenium (a-Se) and polycrystalline mercuric iodide (poly-HgI2) detectors. The charge carrier trapping has a significant effect on DQE in both a-Se and poly-HgI2 detectors. The charge carrier transport properties have higher influences on DQE performance in a-Se detectors than that in HgI2 detectors, because of relatively low conversion gain in a-Se detectors. High conversion gain can minimise the adverse effect of incomplete charge collection. A simplified model for the calculation of zero spatial frequency detective quantum efficiency, DQE(0), under parallel cascaded system is also proposed in this study. There exists an optimum photoconductor thickness, which maximises the DQE(0). The proposed model is compared with the published measured data and shows good agreement.Keywords
This publication has 24 references indexed in Scilit:
- Status of Direct Conversion Detectors for Medical Imaging With X-RaysIEEE Transactions on Nuclear Science, 2009
- The design and imaging characteristics of dynamic, solid-state, flat-panel x-ray image detectors for digital fluoroscopy and fluorographyClinical Radiology, 2008
- Photoconductors for X-Ray Image Detectors2006
- Flat detectors and their clinical applicationsEuropean Radiology, 2005
- Modulation transfer function of photoconductive x-ray image detectors: effects of charge carrier trappingJournal of Physics D: Applied Physics, 2003
- Imaging performance of amorphous selenium based flat-panel detectors for digital mammography: Characterization of a small area prototype detectorMedical Physics, 2003
- Linear-systems modeling of parallel cascaded stochastic processes: the NPS of radiographic screens with reabsorption of characteristic x-radiation1998
- Digital radiology using active matrix readout of amorphous selenium: Theoretical analysis of detective quantum efficiencyMedical Physics, 1997
- X‐ray imaging using amorphous selenium: Inherent spatial resolutionMedical Physics, 1995
- Detective quantum efficiency of imaging systems with amplifying and scattering mechanismsJournal of the Optical Society of America A, 1987