Posterior corneal astigmatism: a review article
Open Access
- 1 August 2019
- journal article
- review article
- Published by Taylor & Francis in Clinical Optometry
- Vol. ume 11, 85-96
Abstract
Most human eyes show at least a small degree of corneal astigmatism and it can arise from both surfaces of the cornea. The shape of the anterior corneal surface provides no definitive basis for knowing the toricity of the posterior surface. In the previous studies, average astigmatism of the posterior corneal surface was -0.26 to -0.78 diopter. The radius of the posterior corneal surface is less than the radius of the anterior corneal surface. Most studies have found a clear correlation between the anterior and posterior corneal asphericities and the asphericity of the posterior surface is independent of the vertex radius of curvature, refractive error and gender. In contrast to the anterior corneal surface, the asphericity of the posterior corneal surface varies significantly between meridians. The anterior and posterior corneal surface would have approximately parallel principal meridians and both of these surfaces are often flatter in the horizontal meridian than the vertical one. This is especially true in the higher degrees of corneal astigmatism, and then about 10% of any anterior corneal astigmatism is neutralized by an astigmatism arising from the posterior corneal surface. Although the second corneal surface only contributes to about 10% of the total refractive power of the eye, a precise knowledge of its morphology is needed for the correct diagnosis and monitoring the corneal diseases or the surgical interventions and in many eyes neglecting the posterior corneal surface measurement may lead to significant deviations from the corneal astigmatism estimation. In this article, we have reviewed the shape and the toricity of the posterior corneal surface and also the effect of age on it. We investigated the contribution of posterior corneal astigmatism to the total corneal astigmatism and evaluated the accuracy of corneal astigmatism estimation by neglecting the posterior corneal surface measurement.Keywords
This publication has 99 references indexed in Scilit:
- Comparison of corneal astigmatism and axis location in cataract patients measured by total corneal power, automated keratometry, and simulated keratometryJournal of Cataract & Refractive Surgery, 2012
- Contribution of posterior corneal astigmatism to total corneal astigmatismJournal of Cataract & Refractive Surgery, 2012
- Which Keratometer is Most Reliable for Correcting Astigmatism with Toric Intraocular Lenses?Korean Journal of Ophthalmology, 2012
- Corneal imaging with slit‐scanning and Scheimpflug imaging techniquesClinical and Experimental Optometry, 2011
- Corneal power measurement with Fourier-domain optical coherence tomographyJournal of Cataract & Refractive Surgery, 2010
- Nature and nurture: the complex genetics of myopia and refractive errorClinical Genetics, 2010
- Effects of Aging on Anterior and Posterior Corneal AstigmatismCornea, 2010
- Stability of the Posterior Corneal Surface After Laser Surface Ablation for MyopiaCornea, 2009
- Correlation between the dioptric power, astigmatism and surface shape of the anterior and posterior corneal surfacesOphthalmic and Physiological Optics, 2009
- Distribution of astigmatism in the adult populationJournal of the Optical Society of America A, 1996