A quantitative analysis of intensity-modulated radiation therapy plans and comparison of homogeneity indices for the treatment of gynecological cancers
Authors:
Open Access
- 1 January 2013
- journal article
- research article
- Published by Medknow in Journal of Medical Physics
- Vol. 38 (2) , 67-73
Abstract
The aim of present study was to evaluate the intensity-modulated radiation therapy (IMRT) plans using different homogeneity and conformity indices in gynecological cancers, as well as to compare and find out the most reliable and accurate measure of the dose homogeneity among the available indices. In this study, a cohort of 12 patients were registered for evaluation, those receiving dynamic IMRT treatment on Clinac-2300C/D linear accelerator with 15-Mega Voltage (MV) photon beam. Dynamic IMRT plans were created on Eclipse treatment planning system with Helios dose volume optimization software. Homogeneity indices (HI) such as H index, modified H index, HI index, modified HI index, and S-index (sigma-index) proposed by M Yoon et al. (2007) were calculated and compared. The values of S-index vary from 1.63 to 2.99. The results indicate that the H and HI indices and their modified versions may not provide the correct dose homogeneity information, but the S-index provides accurate information about the dose homogeneity in the Planning Target Volume (PTV). Each plan was compared with 6-MV photon energy on the basis of S-index and conformity index (CI). Organs at risk (OAR) doses with 6-MV and 15-MV beams were also reported.Keywords
This publication has 23 references indexed in Scilit:
- Dosimetric advantages of generalised equivalent uniform dose-based optimisation on dose–volume objectives in intensity-modulated radiotherapy planning for bilateral breast cancerBritish Journal of Radiology, 2012
- The dosimetric effect of mixed‐energy IMRT plans for prostate cancerJournal of Applied Clinical Medical Physics, 2011
- A computational tool for the efficient analysis of dose-volume histograms for radiation therapy treatment plans2010
- High-precision radiotherapy for craniospinal irradiation: evaluation of three-dimensional conformal radiotherapy, intensity-modulated radiation therapy and helical TomoTherapyBritish Journal of Radiology, 2009
- Comparing planning time, delivery time and plan quality for IMRT, RapidArc and tomotherapyJournal of Applied Clinical Medical Physics, 2009
- Simultaneous beam geometry and intensity map optimization in intensity-modulated radiation therapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2006
- TCP and NTCP: a basic introduction.2005
- Treatment planning comparison of conventional, 3D conformal, and intensity-modulated photon (IMRT) and proton therapy for paranasal sinus carcinomaInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2004
- MLC quality assurance techniques for IMRT applicationsMedical Physics, 2003
- Optimisation of radiotherapy for carcinoma of the parotid gland: a comparison of conventional, three-dimensional conformal, and intensity-modulated techniquesRadiotherapy and Oncology, 2001