PPPushpraj K. Pathak

Pushpraj K. Pathak

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Pushpraj K. Pathak has a total of 7 co-authors. Here are the top co-authors by number of shared publications:

  • P.K. Jithin

    Department of Medical Physics, Jawaharlal Nehru Cancer Hospital and Research Centre, Bhopal, India

    1 shared publication
  • R. Mahawar

    Department of Radiation Oncology, Jawaharlal Nehru Cancer Hospital and Research Centre, Bhopal, India

    1 shared publication
  • S. Baby

    Department of Medical Physics, Jawaharlal Nehru Cancer Hospital and Research Centre, Bhopal, India

    1 shared publication
  • S.K. Vashisht

    Department of Medical Physics, Jawaharlal Nehru Cancer Hospital and Research Centre, Bhopal, India

    1 shared publication
  • Sanjeev Vashisht

    Department of Medical Physics, Jawaharlal Nehru Cancer Hospital and Research Centre, Bhopal, Madhya Pradesh, India

    1 shared publication
  • V.G. G.K. Sharan

    Department of Radiation Oncology, Jawaharlal Nehru Cancer Hospital and Research Centre, Bhopal, India

    1 shared publication

Latest Publications

  • Open Access

    Commissioning and quality assurance of HalcyonTM 2.0 linear accelerator

    by Pushpraj K. Pathak, S.K. Vashisht, S. Baby, P.K. Jithin, Y. Jain, R. Mahawar, V.G. G.K. Sharan

    BACKGROUND: Varian Medical Systems has introduced a new medical linear accelerator called HalcyonTM 2.0, which is based on the ring delivery system (RDS). It is a true IGRT machine having 6MV FFF photon energy. In addition to the planar and MV-CBCT imaging techniques it also has an option of ultra-fast kV-iCBCT which enhances the image reconstruction and improves the visualization of soft tissue. The field portals are shaped by a unique dual layer MLC with special stacked and staggered design which enables high modulation with low radiation leakage. Recently, we have commissioned our first Halcyon 2.0 machine. The aim of this work was to systematically investigate various parameters of a newly installed HalcyonTM 2.0 linear accelerator. MATERIALS AND METHODS: Detailed measurements were conducted as per various guidelines. Also, the measurements were performed to fulfil the national regulatory requirements. Commissioning data of Halcyon 6 MV-FFF beam was performed in a water tank. For absolute measurements, a 0.6-cc waterproof Farmer chamber and electrometer were used. All relative measurements (PDDs, in-line, cross-line and angular profiles) were performed with 0.0125 cc point chamber. RESULTS: All the tests were within the acceptable limit. Measured data were compared with factory data as well as the existing medical linear accelerator of the same category. The obtained results were quite satisfactory. CONCLUSIONS: This study summarizes the commissioning experience with Halcyon linear accelerator. Evaluation of mechanical, radiation safety and dosimetric parameters were performed. The obtained parameters were well below the specified tolerance limits. BACKGROUND: Varian Medical Systems has introduced a new medical linear accelerator called HalcyonTM 2.0, which is based on the ring delivery system (RDS). It is a true IGRT machine having 6MV FFF photon energy. In addition to the planar and MV-CBCT imaging techniques it also has an option of ultra-fast kV-iCBCT which enhances the image reconstruction and improves the visualization of soft tissue. The field portals are shaped by a unique dual layer MLC with special stacked and staggered design which enables high modulation with low radiation leakage. Recently, we have commissioned our first Halcyon 2.0 machine. The aim of this work was to systematically investigate various parameters of a newly installed HalcyonTM 2.0 linear accelerator. MATERIALS AND METHODS: Detailed measurements were conducted as per various guidelines. Also, the measurements were performed to fulfil the national regulatory requirements. Commissioning data of Halcyon 6 MV-FFF beam was performed in a water tank. For absolute measurements, a 0.6-cc waterproof Farmer chamber and electrometer were used. All relative measurements (PDDs, in-line, cross-line and angular profiles) were performed with 0.0125 cc point chamber. RESULTS: All the tests were within the acceptable limit. Measured data were compared with factory data as well as the existing medical linear accelerator of the same category. The obtained results were quite satisfactory. CONCLUSIONS: This study summarizes the commissioning experience with Halcyon linear accelerator. Evaluation of mechanical, radiation safety and dosimetric parameters were performed. The obtained parameters were well below the specified tolerance limits.


  • Open Access

    A quantitative analysis of intensity-modulated radiation therapy plans and comparison of homogeneity indices for the treatment of gynecological cancers

    by Pushpraj Pathak, Sanjeev Vashisht

    The aim of present study was to evaluate the intensity-modulated radiation therapy (IMRT) plans using different homogeneity and conformity indices in gynecological cancers, as well as to compare and find out the most reliable and accurate measure of the dose homogeneity among the available indices. In this study, a cohort of 12 patients were registered for evaluation, those receiving dynamic IMRT treatment on Clinac-2300C/D linear accelerator with 15-Mega Voltage (MV) photon beam. Dynamic IMRT plans were created on Eclipse treatment planning system with Helios dose volume optimization software. Homogeneity indices (HI) such as H index, modified H index, HI index, modified HI index, and S-index (sigma-index) proposed by M Yoon et al. (2007) were calculated and compared. The values of S-index vary from 1.63 to 2.99. The results indicate that the H and HI indices and their modified versions may not provide the correct dose homogeneity information, but the S-index provides accurate information about the dose homogeneity in the Planning Target Volume (PTV). Each plan was compared with 6-MV photon energy on the basis of S-index and conformity index (CI). Organs at risk (OAR) doses with 6-MV and 15-MV beams were also reported.