REFRACTIVE OUTCOME OF SILICONE OIL REMOVAL AND INTRAOCULAR LENS IMPLANTATION USING LASER INTERFEROMETRY

Authors:

Abstract
To evaluate the refractive outcome of silicone oil removal and intraocular lens (IOL) implantation using laser interferometry. Thirteen silicone oil-filled eyes of 12 patients were included in the study. IOL power calculation was performed using laser interferometry (IOLMaster™ V1.1; Carl Zeiss, Jena, Germany). All of these eyes underwent silicone oil removal and cataract extraction with IOL implantation. Post-operative refraction was evaluated. The mean deviation of the final post-operative refraction (spherical equivalent) was −0.30±0.91 D (range, −1.87 to +1.3) at 12 weeks. The mean axial length of the eyes was 22.99±0.84 mm (range, 22.07–25.24 mm). No major complications occurred intra- or post-operatively. Laser interferometry appears to be a feasible and satisfactorily accurate method to calculate IOL power in some silicone oil-filled eyes. Further studies comparing this technique to others are warranted.

This publication has 23 references indexed in Scilit: