Hooshang Faghihi Habibabadi
Research Subjects
Hooshang Faghihi Habibabadi has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
Ali Amini
1 shared publicationHassan Hashemi
1 shared publicationKamran Hodjat Jalali
1 shared publicationMohammad Riazi Esfahani
1 shared publication
Latest Publications
- 1 February 2005
- Published by Wolters Kluwer Health in Retina
- Vol. 25 (2) , 162-166
REFRACTIVE OUTCOME OF SILICONE OIL REMOVAL AND INTRAOCULAR LENS IMPLANTATION USING LASER INTERFEROMETRY
To evaluate the refractive outcome of silicone oil removal and intraocular lens (IOL) implantation using laser interferometry. Thirteen silicone oil-filled eyes of 12 patients were included in the study. IOL power calculation was performed using laser interferometry (IOLMaster™ V1.1; Carl Zeiss, Jena, Germany). All of these eyes underwent silicone oil removal and cataract extraction with IOL implantation. Post-operative refraction was evaluated. The mean deviation of the final post-operative refraction (spherical equivalent) was −0.30±0.91 D (range, −1.87 to +1.3) at 12 weeks. The mean axial length of the eyes was 22.99±0.84 mm (range, 22.07–25.24 mm). No major complications occurred intra- or post-operatively. Laser interferometry appears to be a feasible and satisfactorily accurate method to calculate IOL power in some silicone oil-filled eyes. Further studies comparing this technique to others are warranted.
- 1 February 2005
- Published by Wolters Kluwer Health in Retina
- Vol. 25 (2) , 162-166
REFRACTIVE OUTCOME OF SILICONE OIL REMOVAL AND INTRAOCULAR LENS IMPLANTATION USING LASER INTERFEROMETRY
To evaluate the refractive outcome of silicone oil removal and intraocular lens (IOL) implantation using laser interferometry. Thirteen silicone oil-filled eyes of 12 patients were included in the study. IOL power calculation was performed using laser interferometry (IOLMaster™ V1.1; Carl Zeiss, Jena, Germany). All of these eyes underwent silicone oil removal and cataract extraction with IOL implantation. Post-operative refraction was evaluated. The mean deviation of the final post-operative refraction (spherical equivalent) was −0.30±0.91 D (range, −1.87 to +1.3) at 12 weeks. The mean axial length of the eyes was 22.99±0.84 mm (range, 22.07–25.24 mm). No major complications occurred intra- or post-operatively. Laser interferometry appears to be a feasible and satisfactorily accurate method to calculate IOL power in some silicone oil-filled eyes. Further studies comparing this technique to others are warranted.