In vitro comparison of peracetic acid and autoclave sterilization in the corrosion of orthodontic pliers: a pilot study
Open Access
- 1 January 2021
- journal article
- research article
- Published by FapUNIFESP (SciELO) in Dental Press Journal of Orthodontics
- Vol. 26 (5)
Abstract
Introduction: The most currently recommended method for sterilization of orthodontic pliers is the autoclave, while peracetic acid has also been shown to be effective in the chemical sterilization process. Objective: This study sought to compare the corrosive effects of peracetic acid and autoclave sterilization process of orthodontic pliers. Methods: Four active tungsten carbide (WC) stainless steel tie-cutting pliers from the manufacturers Quinelato (Rio Claro, SP, Brazil) and ICE (Cajamar, SP, Brazil) were selected. The active ends of the pliers were sectioned, and six active tips were obtained and distributed into the following groups: 1) control group (no sterilization); 2) AC group (two active pliers tips submitted to 100 autoclave sterilization cycles); and 3) AP group (two active pliers tips submitted to 100 cycles of sterilization by immersion in 2% peracetic acid solution for 30 minutes). Results: Chemical analysis using X-ray dispersive energy spectroscopy showed that after autoclave sterilization, only the ICE pliers presented oxidation corrosion (Δ[O] = +24.5%; Δ[Fe] = +5.8%; Δ[WC] = -1.9%). In comparison, following peracetic acid sterilization, both manufacturers ICE (Δ[O] = +1.8%; Δ[Fe] = +18.0%; Δ[WC] = -1.1%) and Quinelato (Δ[O] = +5.3%; Δ[Fe] = -10.4%; Δ[WC] = -15.2%) showed corrosion. The morphological analysis revealed that peracetic acid caused a pitting and localized corrosion in both brands, while the autoclave caused uniform surface corrosion on the ICE pliers. Conclusion: Autoclave application was the sterilization method that generated less corrosive damage to the orthodontic cutting pliers, when compared to the immersion in 2% peracetic acid.Keywords
This publication has 16 references indexed in Scilit:
- Evaluation of disinfection methods of orthodontic pliersDental Press Journal of Orthodontics, 2012
- Effects of sterilization and disinfection procedures on the corrosion of orthodontic ligature cuttersInternational Orthodontics, 2012
- Análises microbiológicas de alicates ortodônticosDental Press Journal of Orthodontics, 2011
- Corrosion of Orthodontic Pliers Using Different Sterilization ProceduresJournal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie, 2004
- A between-patient disinfection method to control water line contamination and biofilm inside dental unitsJournal of Hospital Infection, 2004
- Infection controlDental Clinics of North America, 2003
- Infection control in the orthodontic office in CanadaAmerican Journal of Orthodontics and Dentofacial Orthopedics, 1997
- The effect of routine steam autoclaving on orthodontic pliersEuropean Journal of Orthodontics, 1993
- Sterilization and disinfection in the orthodontic office: A practical approachAmerican Journal of Orthodontics and Dentofacial Orthopedics, 1986
- Upgrading sterilization in the orthodontic practiceAmerican Journal of Orthodontics, 1986