HFHelio Rodrigues Sampaio Filho

Helio Rodrigues Sampaio Filho

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Helio Rodrigues Sampaio Filho has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    In vitro comparison of peracetic acid and autoclave sterilization in the corrosion of orthodontic pliers: a pilot study

    by Livia Kelly Ferraz Nunes, Érika Lopes Carneiro, Nathalia Barbosa Palomares, Lilian Senna, Helio Sampaio-Filho, José Augusto Mendes Miguel

    Introduction: The most currently recommended method for sterilization of orthodontic pliers is the autoclave, while peracetic acid has also been shown to be effective in the chemical sterilization process. Objective: This study sought to compare the corrosive effects of peracetic acid and autoclave sterilization process of orthodontic pliers. Methods: Four active tungsten carbide (WC) stainless steel tie-cutting pliers from the manufacturers Quinelato (Rio Claro, SP, Brazil) and ICE (Cajamar, SP, Brazil) were selected. The active ends of the pliers were sectioned, and six active tips were obtained and distributed into the following groups: 1) control group (no sterilization); 2) AC group (two active pliers tips submitted to 100 autoclave sterilization cycles); and 3) AP group (two active pliers tips submitted to 100 cycles of sterilization by immersion in 2% peracetic acid solution for 30 minutes). Results: Chemical analysis using X-ray dispersive energy spectroscopy showed that after autoclave sterilization, only the ICE pliers presented oxidation corrosion (Δ[O] = +24.5%; Δ[Fe] = +5.8%; Δ[WC] = -1.9%). In comparison, following peracetic acid sterilization, both manufacturers ICE (Δ[O] = +1.8%; Δ[Fe] = +18.0%; Δ[WC] = -1.1%) and Quinelato (Δ[O] = +5.3%; Δ[Fe] = -10.4%; Δ[WC] = -15.2%) showed corrosion. The morphological analysis revealed that peracetic acid caused a pitting and localized corrosion in both brands, while the autoclave caused uniform surface corrosion on the ICE pliers. Conclusion: Autoclave application was the sterilization method that generated less corrosive damage to the orthodontic cutting pliers, when compared to the immersion in 2% peracetic acid.

  • Open Access

    How do the optical properties of the bulk fill posterior composites change after 2 years of simulated toothbrushing?

    by Leticia Souza Lopes, Helio Rodrigues Sampaio Filho, Elisa Gomes Albuquerque, Chane Tardem, Mauro Sayão Miranda, Marcos Oliveira Barceleiro

    The objective of this study was to evaluate the alteration of the optical properties of bulk Fill resin-based composites after 2 years of simulated toothbrushing. Three high-viscosity bulk fill resin composites and one conventional sculptable resin composite (control) were analyzed. Five specimens of each resin composite were prepared, and roughness, color, translucency and gloss were evaluated initially and after one and two years of simulated toothbrushing. The specimens were submitted to electric simulated toothbrushing (14600 strokes/100g) using a commercially available toothbrush with soft fibers and toothpaste slurry in a proportion of 1:2 by weight. The brushing scheme was of 40 cycles per day (2 cycles per second / 280 cycles in a week). The optical properties and the roughness data were analyzed by a multifactor analysis of variance (MANOVA) and a Tukey post hoc test. The baseline and final values of Ra and Sa were submitted to linear regression analyses, all of which were performed at a significance level of p=0.05. Gloss and roughness presented statistical differences between the resin-time interactions in all composite resins. The gloss (72.5%) and roughness (89.4%) worsened significantly after brushing, but the authors didn’t find statistically significant differences when evaluating translucency and color. Based in the results, it could be concluded that the simulated brushing degraded the brightness and roughness of the used high-viscosity bulk fill composites.


  • Open Access

    Influence of activation mode, fatigue, and ceramic interposition on resin cements’ diametral tensile strength

    by Paula Nunes Guimarães Paes, Mauro Sayão de Miranda, Hélio Rodrigues Sampaio-Filho, Lourenço Correr-Sobrinho

    This study evaluated the influence of activation modes, on Diametral Tensile Strength (DTS) of dual cured resin cements subjected to a Mechanical Fatigue test (MF). Four dual-cured resin cements (RelyX UNICEM [U], RelyX ARC [A], ENFORCE [E] and Nexus 2 [N]) were activated by three different curing modes as follows: Self-Curing (SC), Dual Cure activation with photoactivation executed directly (DC) and Dual Cure activation with Photoactivation Through Porcelain (DCTP). After 24 hours, half of the sample was subjected to 30.000 fatigue cycles at 1 Hz frequency and 12 N load. Then, all specimens were subjected to DTS test in Instron Universal Testing Machine and data were analyzed by three-way ANOVA and Tukey’s Test (5%). The results of DTS test means (MPa) and standard deviation, for each cement factor activated by SC, DC and DCTP was respectively: U (28.12 ± 5.29; 37.44 ± 6.49 and 40.10 ± 4.39), A (49.68 ± 8.42; 55.12 ± 5.16 and 63.43 ± 6.92), E (49.12 ± 3.89; 56.42 ± 8.88 and 56.96 ± 6.45) and N (61.89 ± 11.21; 59.26 ± 9.47 and 62.56 ± 10.93). Turkey’s test indicated that DC is related to the highest DTS values; Nexus 2 DTS remained the same independently of activation mode and that the Porcelain disk interposition enhanced DTS only for RelyX ARC the ANOVA statistical test indicated that MF didn’t alter the DTS values for all experimental groups. MF results clinical implication is that all cements tested exhibited, in an immediate loading, good cross linked bonds quality.


  • Does the retention system influence the stability of implant-supported maxillary overdentures? A comparison with fixed and conventional dentures

    by M.M.M. Michelon, A.T. Posch, H.R. Sampaio-Filho, E.J.V. Lourenco, D.M. Telles

    Purpose: The purpose of this in vitro study was to compare the stability of removable implant-supported maxillary overdentures with fixed complete dentures and conventional dentures. Methods: Four types of complete dentures were tested: conventional complete dentures; overdentures retained by a male resilient attachment system; overdentures retained by a combination of clip bar and attachment system; and fixed complete dentures. Each group was placed in the posterior and anterior region and the stability was recorded by measuring the vertical displacement of the prosthesis. Results: There was a difference in the vertical movement of the prosthesis according to the type of system. The results showed that the behavior of the overdenture retained by a combination of a clip bar and attachment system is comparable with the stabilization of an implant-retained fixed complete denture. Conclusions: Overdentures retained by a combination of a clip bar and attachment presented better stability and retention capacity under our experimental conditions, close to that of the positive control (fixed complete denture), with the advantages of removable overdentures. (c) 2018 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.