Patient’s body composition can significantly affect RF power deposition in the tissue around DBS implants: ramifications for lead management strategies and MRI field-shaping techniques
- 14 January 2021
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (1) , 015008
Abstract
Patients with active implants such as deep brain stimulation (DBS) devices have limited access to magnetic resonance imaging (MRI) due to risks associated with RF heating of implants in MRI environment. With an aging population and increased prevalence of neurodegenerative disease, the indication for MRI exams in patients with such implants increases as well. In response to this growing need, many groups have investigated strategies to mitigate RF heating of DBS implants during MRI. These efforts fall into two main categories: MRI field-shaping methods, where the electric field of the MRI RF coil is modified to reduce the interaction with implanted leads, and lead management techniques where surgical modifications in the trajectory reduces the coupling with RF fields. Studies that characterize these techniques, however, have relied either on simulations with homogenous body models, or experiments with box-shaped single-material phantoms. It is well established, however, that the shape and heterogeneity of human body affects the distribution of RF electric fields, which by proxy, alters the heating of an implant inside the body. In this contribution, we applied numerical simulations and phantom experiments to examine the degree to which variations in patient’s body composition affects RF power deposition. We then assessed effectiveness of RF-heating mitigation strategies under variant patient body compositions. Our results demonstrated that patient’s body composition substantially alters RF power deposition in the tissue around implanted leads. However, both techniques based on MRI field-shaping and DBS lead management performed well under variant body types.Keywords
Funding Information
- Norges Idrettshøgskole (R00EB021320)
This publication has 40 references indexed in Scilit:
- Combined use of transcranial magnetic stimulation and metal electrode implants: a theoretical assessment of safety considerationsPhysics in Medicine & Biology, 2012
- Heating induced near deep brain stimulation lead electrodes during magnetic resonance imaging with a 3 T transceive volume head coilPhysics in Medicine & Biology, 2012
- Effect of the extracranial deep brain stimulation lead on radiofrequency heating at 9.4 Tesla (400.2 MHz)Journal of Magnetic Resonance Imaging, 2010
- Evaluation of Cumulative Effects of MR Imaging on Pacemaker Systems at 1.5 TeslaPacing and Clinical Electrophysiology, 2009
- Electrodynamic constraints on homogeneity and radiofrequency power deposition in multiple coil excitationsMagnetic Resonance in Medicine, 2009
- Spatial distribution of RF‐induced E‐fields and implant heating in MRIMagnetic Resonance in Medicine, 2008
- Calculation of MRI‐induced heating of an implanted medical lead wire with an electric field transfer functionJournal of Magnetic Resonance Imaging, 2007
- Radio frequency versus susceptibility effects of small conductive implants — a systematic MRI study on aneurysm clips at 1.5 and 3 TMagnetic Resonance Imaging, 2005
- Current Clinical Issues for MRI Scanning of Pacemaker and Defibrillator PatientsPacing and Clinical Electrophysiology, 2005
- Nonsusceptibility artifacts due to metallic objects in MR imagingJournal of Magnetic Resonance Imaging, 1995