Flame-induced laser Doppler velocimetry velocity bias

Authors:

Abstract
Laser Doppler velocimetry (LDV) measurements are often made in the presence of transient index of refraction variations which bias the measured velocity. Transient temperature variation (e.g. as found in turbulent combustion or turbulent convective heat transfer situations) is the most common mechanism driving index of refraction changes in systems probed with LDV. The physical phenomena inducing this bias, referred to here as flame-induced velocity bias (FIVB), are outlined. Combustion system velocity RMS biases of 10% are possible. The literature currently lacks a model to predict, and a list of criteria to minimize, FIVB. To fill this need a model is developed to predict the magnitude of FIVB. Predictions are compared to experimental measurements of FIVB in a pool fire to confirm the validity of the model. Specific criteria identified for minimizing the FIVB include maximizing the beam crossing angle magnitude; using a Bragg cell frequency shift to reduce sampling times to less than 1 mu s; using the longest laser wavelength available; orienting beams parallel to index of refraction gradients to minimize the beam incidence angles; and when measuring velocities perpendicular to the main flow direction, orienting the beams such that the main flow is along the bisector of the beam crossing angle. Contrary to intuition, minimizing beam steering displacements by minimizing flame front to probe volume distance may increase the FIVB.