Abstract
The feasibility of high-rate treatment of storm water achieving total suspended solids (TSS) removals in the range from 60 to 80% was studied using an available clarifier. The clarifier ( 3 m long, 1.4 m wide, and 2 m deep) was fitted with a removable lamella pack and had a limited flow capacity (surface load rate of 35 m∕h ). To achieve the desired removals of TSS, the clarifier required polymer feed (4 mg∕L) , which caused maintenance problems during intermittent storm-water treatment—laborious and costly cleaning of lamella plates after individual storm events. This problem posed the following challenge: was it feasible to avoid costly maintenance by removing the lamella pack and at the same time to retain the high TSS removals by improving the clarifier hydraulics by internal structural changes? The purpose of the paper is to evaluate such changes by focusing on different inlet configurations designed using computational fluid dynamics (CFD) simulations. This analysis resulted in adopting a U-tube duc...

This publication has 11 references indexed in Scilit: