Water-equivalent fiber radiation dosimeter with two scintillating materials
Open Access
- 3 November 2016
- journal article
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 7 (12) , 4919-4927
Abstract
An inorganic scintillating material plastic optical fiber (POF) dosimeter for measuring ionizing radiation during radiotherapy applications is reported. It is necessary that an ideal dosimeter exhibits many desirable qualities, including water equivalence, energy independence, reproducibility, dose linearity. There has been much recent research concerning inorganic dosimeters. However, little reference has been made to date of the depth-dose characteristics of dosimeter materials. In the case of inorganic scintillating materials, they are predominantly non water-equivalent, with their effective atomic weight (Zeff) being typically much greater than that of water. This has been a barrier in preventing inorganic scintillating material dosimeter from being used in actual clinical applications. In this paper, we propose a parallel-paired fiber light guide structure to solve this problem. Two different inorganic scintillating materials are embedded separately in the parallel-paired fiber. It is shown that the information of water depth and absorbed dose at the point of measurement can be extracted by utilizing their different depth-dose properties.Keywords
Funding Information
- Chinese Academy of Sciences (CAS)
- Joint Research Fund in Astronomy (U1331114)
- National Natural Science Foundation of China (NSFC)
- the 111 Project (B13015)
- the Fundamental Research Funds for the Central Universities to the Harbin Engineering University
- The International Science & Technology Cooperation Program of China (2014DFE10030)
This publication has 24 references indexed in Scilit:
- In vivo dosimetry in external beam radiotherapyMedical Physics, 2013
- In vivo dosimetry in brachytherapyMedical Physics, 2013
- Radiotherapy dosimetry based on plastic optical fibre sensors2013
- Unintended exposure in radiotherapy: Identification of prominent causesRadiotherapy and Oncology, 2009
- Dosimetric characteristics of a MOSFET dosimeter for clinical electron beamsPhysica Medica, 2009
- An international review of patient safety measures in radiotherapy practiceRadiotherapy and Oncology, 2009
- Characterization of a water‐equivalent fiber‐optic coupled dosimeter for use in diagnostic radiologyMedical Physics, 2009
- Potential clinical utility of a fibre optic-coupled dosemeter for dose measurements in diagnostic radiologyRadiation Protection Dosimetry, 2008
- Characterization of a fiber‐optic‐coupled radioluminescent detector for application in the mammography energy rangeMedical Physics, 2007
- In vivo dosimeters for HDR brachytherapy: A comparison of a diamond detector, MOSFET, TLD, and scintillation detectorMedical Physics, 2007