Microdosimetric and Biological Effects of Photon Irradiation at Different Energies in Bone Marrow
- 1 October 2015
- journal article
- Published by Radiation Research Society in Radiation Research
- Vol. 184 (4) , 378-391
Abstract
To ensure reliability and reproducibility of radiobiological data, it is necessary to standardize dosimetry practices across all research institutions. The photoelectric effect predominates over other interactions at low energy and in high atomic number materials such as bone, which can lead to increased dose deposition in soft tissue adjacent to mineral bone due to secondary radiation particles. This may produce radiation effects that deviate from higher energy photon irradiation that best model exposure from clinical radiotherapy or nuclear incidences. Past theoretical considerations have indicated that this process should affect radiation exposure of neighboring bone marrow (BM) and account for reported differences in relative biological effectiveness (RBE) for hematopoietic failure in rodents. The studies described herein definitively estimate spatial dose distribution and biological effectiveness within the BM compartment for 137Cs gamma rays and 320 kVp X rays at two levels of filtration: 1 and 4 mm Cu half-value layer (HVL). In these studies, we performed: 1. Monte Carlo simulations on a 5 μm resolution model of mouse vertebrae and femur derived from micro-CT images; 2. In vitro biological experiments irradiating BM cells plated directly on the surface of a bone-equivalent material (BEM); and 3. An in vivo study on BM cell survival in irradiated live mice. Simulation results showed that the relative dose increased in proximity to bone at the lower radiation energies and produced averaged values of relative dose over the entire BM volume within imaged trabecular bone of 1.17, 1.08 and 1.01 for beam qualities of 1 mm Cu HVL, 4 mm Cu HVL and 137Cs, respectively. In accordance with Monte Carlo simulations, in vitro irradiation of BM cells located on BEM and in vivo whole-body irradiation at a prescribed dose to soft tissue of 6 Gy produced relative cell killing of hematopoietic progenitors (CFU-C) that significantly increased for the 1 mm Cu HVL X rays compared to radiation exposures of higher photon energies. Thus, we propose that X rays of the highest possible kVp and filtration be used to investigate radiation effects on the hematopoietic system, as this will allow for better comparisons with high-energy photon exposures applied in radiotherapy or as anticipated in a nuclear event.Keywords
This publication has 32 references indexed in Scilit:
- Response functions for computing absorbed dose to skeletal tissues from photon irradiation—an updatePhysics in Medicine & Biology, 2011
- Spatial gradients of blood vessels and hematopoietic stem and progenitor cells within the marrow cavities of the human skeletonBlood, 2009
- Replacement of 137Cs Irradiators with X-ray IrradiatorsHealth Physics, 2009
- Validation of Metal Oxide Semiconductor Field Effect Transistor Technology for Organ Dose Assessment During CT: Comparison with Thermoluminescent DosimetryAmerican Journal of Roentgenology, 2007
- Distribution of hematopoietic stem cells in the bone marrow according to regional hypoxiaProceedings of the National Academy of Sciences of the United States of America, 2007
- An assessment of bone marrow and bone endosteum dosimetry methods for photon sourcesPhysics in Medicine & Biology, 2006
- The variation in biological effectiveness of X-rays and gamma rays with energyRadiation Protection Dosimetry, 2004
- Development of a 4-D digital mouse phantom for molecular imaging researchMolecular Imaging and Biology, 2004
- Photoelectron Enhancement of the Absorbed Dose from X Rays to Human Bone Marrow: Experimental and Theoretical StudiesBritish Journal of Radiology, 1985
- Some Experiments relating to Dose in a Model of Trabecular BoneBritish Journal of Radiology, 1966