Matthew D. Belley
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Matthew D. Belley has a total of 70 co-authors. Here are the top co-authors by number of shared publications:
Terry T. Yoshizumi
B Duke Radiation Dosimetry Laboratory and
5 shared publicationsGiao Nguyen
Duke Univ, Med Ctr, Duke Radiat Dosimetry Lab, Durham, NC 27710 USA
4 shared publicationsChu Wang
Medical Physics Graduate Program, Duke University Medical Center, Durham, North Carolina 27705 and Duke Radiation Dosimetry Laboratory, Duke University Medical Center, Durham, North Carolina 27710
3 shared publicationsI Stanton
University of North Carolina and North Carolina State University, Chapel Hill, NC
3 shared publicationsIan N. Stanton
3 shared publicationsM Therien
University of North Carolina and North Carolina State University, Chapel Hill, NC
3 shared publications
Latest Publications
- 1 October 2015
- Published by Radiation Research Society in Radiation Research
- Vol. 184 (4) , 378-391
Microdosimetric and Biological Effects of Photon Irradiation at Different Energies in Bone Marrow
To ensure reliability and reproducibility of radiobiological data, it is necessary to standardize dosimetry practices across all research institutions. The photoelectric effect predominates over other interactions at low energy and in high atomic number materials such as bone, which can lead to increased dose deposition in soft tissue adjacent to mineral bone due to secondary radiation particles. This may produce radiation effects that deviate from higher energy photon irradiation that best model exposure from clinical radiotherapy or nuclear incidences. Past theoretical considerations have indicated that this process should affect radiation exposure of neighboring bone marrow (BM) and account for reported differences in relative biological effectiveness (RBE) for hematopoietic failure in rodents. The studies described herein definitively estimate spatial dose distribution and biological effectiveness within the BM compartment for 137Cs gamma rays and 320 kVp X rays at two levels of filtration: 1 and 4 mm Cu half-value layer (HVL). In these studies, we performed: 1. Monte Carlo simulations on a 5 μm resolution model of mouse vertebrae and femur derived from micro-CT images; 2. In vitro biological experiments irradiating BM cells plated directly on the surface of a bone-equivalent material (BEM); and 3. An in vivo study on BM cell survival in irradiated live mice. Simulation results showed that the relative dose increased in proximity to bone at the lower radiation energies and produced averaged values of relative dose over the entire BM volume within imaged trabecular bone of 1.17, 1.08 and 1.01 for beam qualities of 1 mm Cu HVL, 4 mm Cu HVL and 137Cs, respectively. In accordance with Monte Carlo simulations, in vitro irradiation of BM cells located on BEM and in vivo whole-body irradiation at a prescribed dose to soft tissue of 6 Gy produced relative cell killing of hematopoietic progenitors (CFU-C) that significantly increased for the 1 mm Cu HVL X rays compared to radiation exposures of higher photon energies. Thus, we propose that X rays of the highest possible kVp and filtration be used to investigate radiation effects on the hematopoietic system, as this will allow for better comparisons with high-energy photon exposures applied in radiotherapy or as anticipated in a nuclear event.
- 1 October 2015
- Published by Radiation Research Society in Radiation Research
- Vol. 184 (4) , 378-391
Microdosimetric and Biological Effects of Photon Irradiation at Different Energies in Bone Marrow
To ensure reliability and reproducibility of radiobiological data, it is necessary to standardize dosimetry practices across all research institutions. The photoelectric effect predominates over other interactions at low energy and in high atomic number materials such as bone, which can lead to increased dose deposition in soft tissue adjacent to mineral bone due to secondary radiation particles. This may produce radiation effects that deviate from higher energy photon irradiation that best model exposure from clinical radiotherapy or nuclear incidences. Past theoretical considerations have indicated that this process should affect radiation exposure of neighboring bone marrow (BM) and account for reported differences in relative biological effectiveness (RBE) for hematopoietic failure in rodents. The studies described herein definitively estimate spatial dose distribution and biological effectiveness within the BM compartment for 137Cs gamma rays and 320 kVp X rays at two levels of filtration: 1 and 4 mm Cu half-value layer (HVL). In these studies, we performed: 1. Monte Carlo simulations on a 5 μm resolution model of mouse vertebrae and femur derived from micro-CT images; 2. In vitro biological experiments irradiating BM cells plated directly on the surface of a bone-equivalent material (BEM); and 3. An in vivo study on BM cell survival in irradiated live mice. Simulation results showed that the relative dose increased in proximity to bone at the lower radiation energies and produced averaged values of relative dose over the entire BM volume within imaged trabecular bone of 1.17, 1.08 and 1.01 for beam qualities of 1 mm Cu HVL, 4 mm Cu HVL and 137Cs, respectively. In accordance with Monte Carlo simulations, in vitro irradiation of BM cells located on BEM and in vivo whole-body irradiation at a prescribed dose to soft tissue of 6 Gy produced relative cell killing of hematopoietic progenitors (CFU-C) that significantly increased for the 1 mm Cu HVL X rays compared to radiation exposures of higher photon energies. Thus, we propose that X rays of the highest possible kVp and filtration be used to investigate radiation effects on the hematopoietic system, as this will allow for better comparisons with high-energy photon exposures applied in radiotherapy or as anticipated in a nuclear event.
- 29 June 2015
- Published by Wiley in Medical Physics
- Vol. 42 (6Part36) , 3652
WE-AB-BRB-12: Nanoscintillator Fiber-Optic Detector System for Microbeam Radiation Therapy Dosimetry
- 29 June 2015
- Published by Wiley in Medical Physics
- Vol. 42 (6Part36) , 3652
WE-AB-BRB-12: Nanoscintillator Fiber-Optic Detector System for Microbeam Radiation Therapy Dosimetry
- 27 March 2015
- Published by Wiley in Medical Physics
- Vol. 42 (4) , 1966-1972
Fiber‐optic detector for real time dosimetry of a micro‐planar x‐ray beam
Purpose: Here, the authors describe a dosimetry measurement technique for microbeam radiation therapy using a nanoparticle‐terminated fiber‐optic dosimeter (nano‐FOD).Methods: The nano‐FOD was placed in the center of a 2 cm diameter mouse phantom to measure the deep tissue dose and lateral beam profile of a planar x‐ray microbeam.Results: The continuous dose rate at the x‐ray microbeam peak measured with the nano‐FOD was 1.91 ± 0.06 cGy s−1, a value 2.7% higher than that determined via radiochromic film measurements (1.86 ± 0.15 cGy s−1). The nano‐FOD‐determined lateral beam full‐width half max value of 420 μm exceeded that measured using radiochromic film (320 μm). Due to the 8° angle of the collimated microbeam and resulting volumetric effects within the scintillator, the profile measurements reported here are estimated to achieve a resolution of ∼0.1 mm; however, for a beam angle of 0°, the theoretical resolution would approach the thickness of the scintillator (∼0.01 mm).Conclusions: This work provides proof‐of‐concept data and demonstrates that the novel nano‐FOD device can be used to perform real‐time dosimetry in microbeam radiation therapy to measure the continuous dose rate at the x‐ray microbeam peak as well as the lateral beam shape.
- 27 March 2015
- Published by Wiley in Medical Physics
- Vol. 42 (4) , 1966-1972
Fiber‐optic detector for real time dosimetry of a micro‐planar x‐ray beam
Purpose: Here, the authors describe a dosimetry measurement technique for microbeam radiation therapy using a nanoparticle‐terminated fiber‐optic dosimeter (nano‐FOD).Methods: The nano‐FOD was placed in the center of a 2 cm diameter mouse phantom to measure the deep tissue dose and lateral beam profile of a planar x‐ray microbeam.Results: The continuous dose rate at the x‐ray microbeam peak measured with the nano‐FOD was 1.91 ± 0.06 cGy s−1, a value 2.7% higher than that determined via radiochromic film measurements (1.86 ± 0.15 cGy s−1). The nano‐FOD‐determined lateral beam full‐width half max value of 420 μm exceeded that measured using radiochromic film (320 μm). Due to the 8° angle of the collimated microbeam and resulting volumetric effects within the scintillator, the profile measurements reported here are estimated to achieve a resolution of ∼0.1 mm; however, for a beam angle of 0°, the theoretical resolution would approach the thickness of the scintillator (∼0.01 mm).Conclusions: This work provides proof‐of‐concept data and demonstrates that the novel nano‐FOD device can be used to perform real‐time dosimetry in microbeam radiation therapy to measure the continuous dose rate at the x‐ray microbeam peak as well as the lateral beam shape.
- Open Access
- 22 January 2015
- Published by Wiley in Medical Physics
- Vol. 42 (2) , 846-855
Investigating the accuracy of microstereotactic‐body‐radiotherapy utilizing anatomically accurate 3D printed rodent‐morphic dosimeters
Purpose: Sophisticated small animal irradiators, incorporating cone‐beam‐CT image‐guidance, have recently been developed which enable exploration of the efficacy of advanced radiation treatments in the preclinical setting. Microstereotactic‐body‐radiation‐therapy (microSBRT) is one technique of interest, utilizing field sizes in the range of 1–15 mm. Verification of the accuracy of microSBRT treatment delivery is challenging due to the lack of available methods to comprehensively measure dose distributions in representative phantoms with sufficiently high spatial resolution and in 3 dimensions (3D). This work introduces a potential solution in the form of anatomically accurate rodent‐morphic 3D dosimeters compatible with ultrahigh resolution (0.3 mm3) optical computed tomography (optical‐CT) dose read‐out.Methods: Rodent‐morphic dosimeters were produced by 3D‐printing molds of rodent anatomy directly from contours defined on x‐ray CT data sets of rats and mice, and using these molds to create tissue‐equivalent radiochromic 3D dosimeters from Presage. Anatomically accurate spines were incorporated into some dosimeters, by first 3D printing the spine mold, then forming a high‐Z bone equivalent spine insert. This spine insert was then set inside the tissue equivalent body mold. The high‐Z spinal insert enabled representative cone‐beam CT IGRT targeting. On irradiation, a linear radiochromic change in optical‐density occurs in the dosimeter, which is proportional to absorbed dose, and was read out using optical‐CT in high‐resolution (0.5 mm isotropic voxels). Optical‐CT data were converted to absolute dose in two ways: (i) using a calibration curve derived from other Presage dosimeters from the same batch, and (ii) by independent measurement of calibrated dose at a point using a novel detector comprised of a yttrium oxide based nanocrystalline scintillator, with a submillimeter active length. A microSBRT spinal treatment was delivered consisting of a 180° continuous arc at 225 kVp with a 20 × 10 mm field size. Dose response was evaluated using both the Presage/optical‐CT 3D dosimetry system described above, and independent verification in select planes using EBT2 radiochromic film placed inside rodent‐morphic dosimeters that had been sectioned in half.Results: Rodent‐morphic 3D dosimeters were successfully produced from Presage radiochromic material by utilizing 3D printed molds of rat CT contours. The dosimeters were found to be compatible with optical‐CT dose readout in high‐resolution 3D (0.5 mm isotropic voxels) with minimal artifacts or noise. Cone‐beam CT image guidance was possible with these dosimeters due to sufficient contrast between high‐Z spinal inserts and tissue equivalent Presage material (CNR ∼10 on CBCT images). Dose at isocenter measured with optical‐CT was found to agree with nanoscintillator measurement to within 2.8%. Maximum dose in line profiles taken through Presage and film dose slices agreed within 3%, with FWHM measurements through each profile found to agree within 2%.Conclusions: This work demonstrates the feasibility of using 3D printing technology to make anatomically accurate Presage rodent‐morphic dosimeters incorporating spinal‐mimicking inserts. High quality optical‐CT 3D dosimetry is feasible on these dosimeters, despite the irregular surfaces and implanted inserts. The ability to measure dose distributions in anatomically accurate phantoms represents a powerful useful additional verification tool for preclinical microSBRT.
- 22 January 2015
- Published by Wiley in Medical Physics
- Vol. 42 (2) , 846-855
Open AccessInvestigating the accuracy of microstereotactic‐body‐radiotherapy utilizing anatomically accurate 3D printed rodent‐morphic dosimeters
Purpose: Sophisticated small animal irradiators, incorporating cone‐beam‐CT image‐guidance, have recently been developed which enable exploration of the efficacy of advanced radiation treatments in the preclinical setting. Microstereotactic‐body‐radiation‐therapy (microSBRT) is one technique of interest, utilizing field sizes in the range of 1–15 mm. Verification of the accuracy of microSBRT treatment delivery is challenging due to the lack of available methods to comprehensively measure dose distributions in representative phantoms with sufficiently high spatial resolution and in 3 dimensions (3D). This work introduces a potential solution in the form of anatomically accurate rodent‐morphic 3D dosimeters compatible with ultrahigh resolution (0.3 mm3) optical computed tomography (optical‐CT) dose read‐out.Methods: Rodent‐morphic dosimeters were produced by 3D‐printing molds of rodent anatomy directly from contours defined on x‐ray CT data sets of rats and mice, and using these molds to create tissue‐equivalent radiochromic 3D dosimeters from Presage. Anatomically accurate spines were incorporated into some dosimeters, by first 3D printing the spine mold, then forming a high‐Z bone equivalent spine insert. This spine insert was then set inside the tissue equivalent body mold. The high‐Z spinal insert enabled representative cone‐beam CT IGRT targeting. On irradiation, a linear radiochromic change in optical‐density occurs in the dosimeter, which is proportional to absorbed dose, and was read out using optical‐CT in high‐resolution (0.5 mm isotropic voxels). Optical‐CT data were converted to absolute dose in two ways: (i) using a calibration curve derived from other Presage dosimeters from the same batch, and (ii) by independent measurement of calibrated dose at a point using a novel detector comprised of a yttrium oxide based nanocrystalline scintillator, with a submillimeter active length. A microSBRT spinal treatment was delivered consisting of a 180° continuous arc at 225 kVp with a 20 × 10 mm field size. Dose response was evaluated using both the Presage/optical‐CT 3D dosimetry system described above, and independent verification in select planes using EBT2 radiochromic film placed inside rodent‐morphic dosimeters that had been sectioned in half.Results: Rodent‐morphic 3D dosimeters were successfully produced from Presage radiochromic material by utilizing 3D printed molds of rat CT contours. The dosimeters were found to be compatible with optical‐CT dose readout in high‐resolution 3D (0.5 mm isotropic voxels) with minimal artifacts or noise. Cone‐beam CT image guidance was possible with these dosimeters due to sufficient contrast between high‐Z spinal inserts and tissue equivalent Presage material (CNR ∼10 on CBCT images). Dose at isocenter measured with optical‐CT was found to agree with nanoscintillator measurement to within 2.8%. Maximum dose in line profiles taken through Presage and film dose slices agreed within 3%, with FWHM measurements through each profile found to agree within 2%.Conclusions: This work demonstrates the feasibility of using 3D printing technology to make anatomically accurate Presage rodent‐morphic dosimeters incorporating spinal‐mimicking inserts. High quality optical‐CT 3D dosimetry is feasible on these dosimeters, despite the irregular surfaces and implanted inserts. The ability to measure dose distributions in anatomically accurate phantoms represents a powerful useful additional verification tool for preclinical microSBRT.
- 16 July 2014
- Published by Wiley in Medical Physics
- Vol. 41 (8Part1) , 084101
Verification of a novel method for tube voltage constancy measurement of orthovoltage x‐ray irradiators
Purpose: For orthovoltage x‐ray irradiators, the tube voltage is one of the most fundamental system parameters as this directly relates to the dosimetry in radiation biology studies; however, to the best of our knowledge, there is no commercial portable quality assurance (QA) tool to directly test the constancy of the tube voltage greater than 160 kV. The purpose of this study is to establish the Beam Quality Index (BQI), a quantity strongly correlated to the tube voltage, as an alternative parameter for the verification of the tube voltage as part of the QA program of orthovoltage x‐ray irradiators.Methods: A multipurpose QA meter and its associated data acquisition software were used to customize the measurement parameters to measure the BQI and collect its time‐plot. BQI measurements were performed at 320 kV with four filtration levels on three orthovoltage x‐ray irradiators of the same model, one of which had been recently energy‐calibrated at the factory.Results: For each of the four filtration levels, the measured BQI values were in good agreement (<5%) between the three irradiators. BQI showed filtration‐specificity, possibly due to the difference in beam quality.Conclusions: The BQI has been verified as a feasible alternative for monitoring the constancy of the tube voltage for orthovoltage irradiators. The time‐plot of BQI offers information on the behavior of beam energy at different phases of the irradiation time line. In addition, this would provide power supply performance characteristics from initial ramp‐up to plateau, and finally, the sharp drop‐off at the end of the exposure.
- 16 July 2014
- Published by Wiley in Medical Physics
- Vol. 41 (8Part1) , 084101
Verification of a novel method for tube voltage constancy measurement of orthovoltage x‐ray irradiators
Purpose: For orthovoltage x‐ray irradiators, the tube voltage is one of the most fundamental system parameters as this directly relates to the dosimetry in radiation biology studies; however, to the best of our knowledge, there is no commercial portable quality assurance (QA) tool to directly test the constancy of the tube voltage greater than 160 kV. The purpose of this study is to establish the Beam Quality Index (BQI), a quantity strongly correlated to the tube voltage, as an alternative parameter for the verification of the tube voltage as part of the QA program of orthovoltage x‐ray irradiators.Methods: A multipurpose QA meter and its associated data acquisition software were used to customize the measurement parameters to measure the BQI and collect its time‐plot. BQI measurements were performed at 320 kV with four filtration levels on three orthovoltage x‐ray irradiators of the same model, one of which had been recently energy‐calibrated at the factory.Results: For each of the four filtration levels, the measured BQI values were in good agreement (<5%) between the three irradiators. BQI showed filtration‐specificity, possibly due to the difference in beam quality.Conclusions: The BQI has been verified as a feasible alternative for monitoring the constancy of the tube voltage for orthovoltage irradiators. The time‐plot of BQI offers information on the behavior of beam energy at different phases of the irradiation time line. In addition, this would provide power supply performance characteristics from initial ramp‐up to plateau, and finally, the sharp drop‐off at the end of the exposure.
- 29 May 2014
- Published by Wiley in Medical Physics
- Vol. 41 (6Part30) , 514-515
WE-F-16A-04: Micro-Irradiator Treatment Verification with High-Resolution 3D-Printed Rodent-Morphic Dosimeters
- 29 May 2014
- Published by Wiley in Medical Physics
- Vol. 41 (6Part30) , 514-515
WE-F-16A-04: Micro-Irradiator Treatment Verification with High-Resolution 3D-Printed Rodent-Morphic Dosimeters
- 7 May 2014
- Published by Wiley in Medical Physics
- Vol. 41 (6Part1) , 063902
Assessment of individual organ doses in a realistic human phantom from neutron and gamma stimulated spectroscopy of the breast and liver
Understanding the radiation dose to a patient is essential when considering the use of an ionizing diagnostic imaging test for clinical diagnosis and screening. Using Monte Carlo simulations, the authors estimated the three-dimensional organ-dose distribution from neutron and gamma irradiation of the male liver, female liver, and female breasts for neutron- and gamma-stimulated spectroscopic imaging. Monte Carlo simulations were developed using the Geant4 GATE application and a voxelized XCAT human phantom. A male and a female whole body XCAT phantom was voxelized into 256 × 256 × 600 voxels (3.125 × 3.125 × 3.125 mm(3)). A monoenergetic rectangular beam of 5.0 MeV neutrons or 7.0 MeV photons was made incident on a 2 cm thick slice of the phantom. The beam was rotated at eight different angles around the phantom ranging from 0° to 180°. Absorbed dose was calculated for each individual organ in the body and dose volume histograms were computed to analyze the absolute and relative doses in each organ. The neutron irradiations of the liver showed the highest organ dose absorption in the liver, with appreciably lower doses in other proximal organs. The dose distribution within the irradiated slice exhibited substantial attenuation with increasing depth along the beam path, attenuating to ~15% of the maximum value at the beam exit side. The gamma irradiation of the liver imparted the highest organ dose to the stomach wall. The dose distribution from the gammas showed a region of dose buildup at the beam entrance, followed by a relatively uniform dose distribution to all of the deep tissue structures, attenuating to ~75% of the maximum value at the beam exit side. For the breast scans, both the neutron and gamma irradiation registered maximum organ doses in the breasts, with all other organs receiving less than 1% of the breast dose. Effective doses ranged from 0.22 to 0.37 mSv for the neutron scans and 41 to 66 mSv for the gamma scans. Neutron and gamma irradiation of a primary target organ was found to impart the majority of the total dose to the primary target organ (and other large organs) within the beam plane and considerably lower dose to proximal organs outside of the beam. These results also indicate that despite the use of a highly scattering particle such as a neutron, the dose from neutron stimulated emission computed tomography scans is on par with other clinical imaging techniques such as x-ray computed tomography (x-ray CT). Given the high nonuniformity in the dose across an organ during the neutron scan, care must be taken when computing average doses from neutron irradiations. The effective doses from neutron scanning were found to be comparable to x-ray CT. Further technique modifications are needed to reduce the effective dose levels from the gamma scans.
- 7 May 2014
- Published by Wiley in Medical Physics
- Vol. 41 (6Part1) , 063902
Assessment of individual organ doses in a realistic human phantom from neutron and gamma stimulated spectroscopy of the breast and liver
Understanding the radiation dose to a patient is essential when considering the use of an ionizing diagnostic imaging test for clinical diagnosis and screening. Using Monte Carlo simulations, the authors estimated the three-dimensional organ-dose distribution from neutron and gamma irradiation of the male liver, female liver, and female breasts for neutron- and gamma-stimulated spectroscopic imaging. Monte Carlo simulations were developed using the Geant4 GATE application and a voxelized XCAT human phantom. A male and a female whole body XCAT phantom was voxelized into 256 × 256 × 600 voxels (3.125 × 3.125 × 3.125 mm(3)). A monoenergetic rectangular beam of 5.0 MeV neutrons or 7.0 MeV photons was made incident on a 2 cm thick slice of the phantom. The beam was rotated at eight different angles around the phantom ranging from 0° to 180°. Absorbed dose was calculated for each individual organ in the body and dose volume histograms were computed to analyze the absolute and relative doses in each organ. The neutron irradiations of the liver showed the highest organ dose absorption in the liver, with appreciably lower doses in other proximal organs. The dose distribution within the irradiated slice exhibited substantial attenuation with increasing depth along the beam path, attenuating to ~15% of the maximum value at the beam exit side. The gamma irradiation of the liver imparted the highest organ dose to the stomach wall. The dose distribution from the gammas showed a region of dose buildup at the beam entrance, followed by a relatively uniform dose distribution to all of the deep tissue structures, attenuating to ~75% of the maximum value at the beam exit side. For the breast scans, both the neutron and gamma irradiation registered maximum organ doses in the breasts, with all other organs receiving less than 1% of the breast dose. Effective doses ranged from 0.22 to 0.37 mSv for the neutron scans and 41 to 66 mSv for the gamma scans. Neutron and gamma irradiation of a primary target organ was found to impart the majority of the total dose to the primary target organ (and other large organs) within the beam plane and considerably lower dose to proximal organs outside of the beam. These results also indicate that despite the use of a highly scattering particle such as a neutron, the dose from neutron stimulated emission computed tomography scans is on par with other clinical imaging techniques such as x-ray computed tomography (x-ray CT). Given the high nonuniformity in the dose across an organ during the neutron scan, care must be taken when computing average doses from neutron irradiations. The effective doses from neutron scanning were found to be comparable to x-ray CT. Further technique modifications are needed to reduce the effective dose levels from the gamma scans.
- 1 May 2014
- Published by Wolters Kluwer Health in Health Physics
- Vol. 106 (5) , 551-557
Accuracy of Effective Dose Estimation in Personal Dosimetry
The purpose of this study was three-fold: (1) to measure the transmission properties of various lead shielding materials, (2) to benchmark the accuracy of commercial film badge readings, and (3) to compare the accuracy of effective dose (ED) conversion factors (CF) of the U.S. Nuclear Regulatory Commission methods to the MOSFET method. The transmission properties of lead aprons and the accuracy of film badges were studied using an ion chamber and monitor. ED was determined using an adult male anthropomorphic phantom that was loaded with 20 diagnostic MOSFET detectors and scanned with a whole body CT protocol at 80, 100, and 120 kVp. One commercial film badge was placed at the collar and one at the waist. Individual organ doses and waist badge readings were corrected for lead apron attenuation. ED was computed using ICRP 103 tissue weighting factors, and ED CFs were calculated by taking the ratio of ED and badge reading. The measured single badge CFs were 0.01 (+/- 14.9%), 0.02 (+/- 9.49%), and 0.04 (+/- 15.7%) for 80, 100, and 120 kVp, respectively. Current regulatory ED CF for the single badge method is 0.3; for the double-badge system, they are 0.04 (collar) and 1.5 (under lead apron at the waist). The double-badge system provides a better coefficient for the collar at 0.04; however, exposure readings under the apron are usually negligible to zero. Based on these findings, the authors recommend the use of ED CF of 0.01 for the single badge system from 80 kVp (effective energy 50.4 keV) data.
- 1 May 2014
- Published by Wolters Kluwer Health in Health Physics
- Vol. 106 (5) , 551-557
Accuracy of Effective Dose Estimation in Personal Dosimetry
The purpose of this study was three-fold: (1) to measure the transmission properties of various lead shielding materials, (2) to benchmark the accuracy of commercial film badge readings, and (3) to compare the accuracy of effective dose (ED) conversion factors (CF) of the U.S. Nuclear Regulatory Commission methods to the MOSFET method. The transmission properties of lead aprons and the accuracy of film badges were studied using an ion chamber and monitor. ED was determined using an adult male anthropomorphic phantom that was loaded with 20 diagnostic MOSFET detectors and scanned with a whole body CT protocol at 80, 100, and 120 kVp. One commercial film badge was placed at the collar and one at the waist. Individual organ doses and waist badge readings were corrected for lead apron attenuation. ED was computed using ICRP 103 tissue weighting factors, and ED CFs were calculated by taking the ratio of ED and badge reading. The measured single badge CFs were 0.01 (+/- 14.9%), 0.02 (+/- 9.49%), and 0.04 (+/- 15.7%) for 80, 100, and 120 kVp, respectively. Current regulatory ED CF for the single badge method is 0.3; for the double-badge system, they are 0.04 (collar) and 1.5 (under lead apron at the waist). The double-badge system provides a better coefficient for the collar at 0.04; however, exposure readings under the apron are usually negligible to zero. Based on these findings, the authors recommend the use of ED CF of 0.01 for the single badge system from 80 kVp (effective energy 50.4 keV) data.
- 13 March 2014
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 6 (10) , 5284-5288
Europium- and lithium-doped yttrium oxide nanocrystals that provide a linear emissive response with X-ray radiation exposure
[Y2−xO3; Eux, Liy] nanocrystals display scintillation responses that correlate linearly with incident radiation exposure at X-ray excitation energies ranging from 40–220 kVp, and thus can serve as sensing elements for next-generation radiation dosimeters designed for diagnostic and therapeutic applications.
- 13 March 2014
- Published by Royal Society of Chemistry (RSC) in Nanoscale
- Vol. 6 (10) , 5284-5288
Europium- and lithium-doped yttrium oxide nanocrystals that provide a linear emissive response with X-ray radiation exposure
[Y2−xO3; Eux, Liy] nanocrystals display scintillation responses that correlate linearly with incident radiation exposure at X-ray excitation energies ranging from 40–220 kVp, and thus can serve as sensing elements for next-generation radiation dosimeters designed for diagnostic and therapeutic applications.