Project BREATHE – Prototype Respirator Evaluation Utilizing Newly Proposed Respirator Test Criteria
Open Access
- 31 December 2017
- journal article
- Published by International Society for Respiratory Protection in Journal of the International Society for Respiratory Protection
- Vol. 34 (1) , 1-9
Abstract
Machine and human subject testing of four prototype filtering facepiece respirators (FFR) and two commercial FFR was carried out utilizing recently proposed respirator test criteria that address healthcare worker-identified comfort and tolerance issues. Overall, two FFR (one prototype, one commercial model) were able to pass all eight criteria and three FFR (two prototypes, one commercial model) were able to pass seven of eight criteria. One prototype FFR was not tested against the criteria due to an inability to obtain satisfactory results on human subject quantitative respirator fit testing. Future studies, testing different models and styles of FFR against the proposed criteria, will be required to gauge the overall utility and effectiveness of the criteria in determining FFR comfort and tolerance issues that may impact user compliance and, by extension, protection.Keywords
This publication has 15 references indexed in Scilit:
- Correlation of Respirator Fit Measured on Human Subjects and a Static Advanced HeadformJournal of Occupational and Environmental Hygiene, 2015
- Impact of Low Filter Resistances on Subjective and Physiological Responses to Filtering Facepiece RespiratorsPLOS ONE, 2013
- B95: A new respirator for health care personnelAmerican Journal of Infection Control, 2013
- Measurement Accuracy of Heart Rate and Respiratory Rate during Graded Exercise and Sustained Exercise in the Heat Using the Zephyr BioHarnessTMInternational Journal of Sports Medicine, 2012
- Absence of consequential changes in physiological, thermal and subjective responses from wearing a surgical maskRespiratory Physiology & Neurobiology, 2012
- N95 Filtering Facepiece Respirator Deadspace Temperature and HumidityJournal of Occupational and Environmental Hygiene, 2012
- Evaluation of a Large-Scale Quantitative Respirator-Fit Testing Program for Healthcare Workers: Survey ResultsInfection Control & Hospital Epidemiology, 2010
- New Respirator Fit Test Panels Representing the Current U.S. Civilian Work ForceJournal of Occupational and Environmental Hygiene, 2007
- Psychophysical scaling with applications in physical work and the perception of exertion.Scandinavian Journal of Work, Environment & Health, 1990
- Thermal comfort of patients in hospital ward areasEpidemiology and Infection, 1977