RRRaymond Joseph Roberge

Raymond Joseph Roberge

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Raymond Joseph Roberge has a total of 37 co-authors. Here are the top co-authors by number of shared publications:

  • Jung-Hyun Kim

    National Institute for Occupational Safety and Health, National Personal Protective Technology Laboratory, Pittsburgh, Pennsylvania 15236

    16 shared publications
  • Jeffrey B. Powell

    National Institute for Occupational Safety and Health, National Personal Protective Technology Laboratory, Pittsburgh, Pennsylvania 15236

    11 shared publications
  • Aitor Coca

    Department of Physical Activity and Sports Sciences, Faculty of Health Sciences, Euneiz University, Vitoria-Gasteiz, Spain

    5 shared publications
  • Andrew J. Palmiero

    National Institute for Occupational Safety and Health, National Personal Protective Technology Laboratory, Pittsburgh, Pennsylvania 15236

    5 shared publications
  • Ronald Eugene Shaffer

    National Personal Protective Technology Laboratory, National Institute for Occupational Safety and Health, Pittsburgh, PA, USA

    3 shared publications
  • Stacey Benson

    National Institute for Occupational Safety and Health, NPPTL, Technology Research Branch , Pittsburgh , Pennsylvania ; University of Pittsburgh, Graduate School of Public Health , Pittsburgh , Pennsylvania

    3 shared publications

Latest Publications

  • Pantallas faciales para el control de infecciones: una revisión

    by Raymond J. Roberge

    Resumen Las pantallas faciales son dispositivos que integran el equipo de protección personal utilizados por muchos trabajadores (por ejemplo, médicos, dentistas, veterinarios) para proteger la zona facial y las membranas mucosas asociadas (ojos, nariz, boca) de salpicaduras, rociadas y aspersiones de fluidos corporales. Generalmente, las pantallas faciales no se utilizan solas, sino junto con otro equipo de protección, por lo que se clasifican como equipo de protección personal complementario. Aunque hay millones de potenciales usuarios de pantallas faciales, las directrices para su uso varían en los distintos organismos gubernamentales y sociedades profesionales y existen pocas investigaciones que indaguen sobre su eficacia.

  • Open Access

    Project BREATHE – Prototype Respirator Evaluation Utilizing Newly Proposed Respirator Test Criteria

    by Jung-Hyun Kim, Raymond J. Roberge, Ronald E. Shaffer, Ziqing Zhuang, Jeffrey B. Powell, Michael Bergman, Andrew J. Palmiero

    Machine and human subject testing of four prototype filtering facepiece respirators (FFR) and two commercial FFR was carried out utilizing recently proposed respirator test criteria that address healthcare worker-identified comfort and tolerance issues. Overall, two FFR (one prototype, one commercial model) were able to pass all eight criteria and three FFR (two prototypes, one commercial model) were able to pass seven of eight criteria. One prototype FFR was not tested against the criteria due to an inability to obtain satisfactory results on human subject quantitative respirator fit testing. Future studies, testing different models and styles of FFR against the proposed criteria, will be required to gauge the overall utility and effectiveness of the criteria in determining FFR comfort and tolerance issues that may impact user compliance and, by extension, protection.

  • Powered air-purifying respirator use in healthcare: Effects on thermal sensations and comfort

    by Jeffrey B. Powell, Jung-Hyun Kim, Raymond J. Roberge

    Twelve subjects wore an N95 filtering facepiece respirator (N95 FFR), one tight-fitting full facepiece powered air-purifying respirator (PAPR), two loose-fitting PAPRs, and one elastomeric/PAPR hybrid for 1 hr each during treadmill walking at 5.6 km/hr while undergoing physiological and subjective response monitoring. No significant interaction (p ≥ .05) was noted between the five respirators in heart rate, respiratory rate, oxygen saturation, transcutaneous carbon dioxide, and perceptions of breathing effort or discomfort, exertion, facial heat, and overall body heat. Respirator deadspace heat/humidity were significantly greater for the N95 FFR, whereas tympanic forehead skin temperatures were significantly greater for the hybrid PAPR. Temperature of the facial skin covered by the respirator was equivalent for the N95 FFR and hybrid PAPR, and both were significantly higher than for the other three PAPRs. Perception of eye dryness was significantly greater for a tight-fitting full facepiece PAPR than the N95 FFR and hybrid PAPR. At a low-moderate work rate over 1 hr, effects on cardiopulmonary variables, breathing perceptions, and facial and overall body heat perceptions did not differ significantly between the four PAPRs and a N95 FFR, but the tight-fitting, full facepiece PAPR increased perceptions of eye dryness. The two loose-fitting PAPRs and the full facepiece tight-fitting PAPR ameliorated exercise-induced increases in facial temperature, but this did not translate to improved perception of facial heat and overall body heat.


  • Umbilical temperature correlation with core and skin temperatures at rest, in the heat and during physical activity

    by Raymond J. Roberge, Jung-Hyun Kim, Patrick Yorio, Aitor Coca, Yongsuk Seo, Tyler Quinn, Ali Aljaroudi, Jeffrey B. Powell

    Purpose: to determine the correlation of umbilical temperatures (Tumb) with simultaneously recorded chest wall temperature (Tchest) and rectal temperature (Trectal) in adults during rest, heat exposure and exercise. Methods: A total of 28 healthy men, wearing different types of clothing (athletic garb, a spandex full body heating garment, firefighter bunker gear) had average and peak umbilical, chest wall and rectal temperature measurements taken during sedentary temperature stabilisation stages, heat exposure periods and active exercise phases. Results: Curvilinear relationships were noted between Tchest and Tumb compared with Trectal and their association became noticeably positive and linear at approximately 35.5 °C. Polynomial regression analysis of Trectal with linear and quadratic forms of Tchest and Tumb indicated an overall R2 of 0.657 and 0.767, respectively. Bivariate analysis of a restricted data set (where Tchest and Tumb ≥35.5°), indicated that Tumb was significantly associated with Trectal (raverage = 0.710, p peak = 0.841, p chest was also significantly associated with Trectal, but less so (raverage = 0.570, p peak = 0.699, p chest when core temperature was ≥35.5 °C.


  • Face shields for infection control: A review

    by Raymond J. Roberge

    Face shields are personal protective equipment devices that are used by many workers (e.g., medical, dental, veterinary) for protection of the facial area and associated mucous membranes (eyes, nose, mouth) from splashes, sprays, and spatter of body fluids. Face shields are generally not used alone, but in conjunction with other protective equipment and are therefore classified as adjunctive personal protective equipment. Although there are millions of potential users of face shields, guidelines for their use vary between governmental agencies and professional societies and little research is available regarding their efficacy.


  • Effect of wearing an N95 filtering facepiece respirator on superomedial orbital infrared indirect brain temperature measurements

    by Travis DiLeo, Raymond J. Roberge, Jung-Hyun Kim

    To determine any effect of wearing a filtering facepiece respirator on brain temperature. Subjects (n = 18) wore a filtering facepiece respirator (FFR) for 1 h at rest while undergoing infrared thermography measurements of the superomedial periobital region of the eye, a non-invasive indirect method of brain temperature measurements we termed the superomedial orbital infrared indirect brain temperature (SOIIBT) measurement. Temperature of the facial skin covered by the FFR, infrared temperature measurements of the tympanic membrane and superficial temporal artery region were concurrently measured, and subjective impressions of thermal comfort obtained simultaneously. The temperature of the skin under the FFR and subjective impressions of thermal discomfort both increased significantly. The mean tympanic membrane temperature did not increase, and the superficial temporal artery region temperature decreased significantly. The SOIIBT values did not change significantly, but subjects who switched from nasal to oronasal breathing during the study (n = 5) experienced a slight increase in the SOIIBT measurements. Wearing a FFR for 1 h at rest does not have a significant effect on brain temperatures, as evaluated by the SOIIBT measurements, but a change in the route of breathing may impact these measurements. These findings suggest that subjective impressions of thermal discomfort from wearing a FFR under the study conditions are more likely the result of local dermal sensations rather than brain warming.


  • Effect of Pregnancy Upon Facial Anthropometrics and Respirator Fit Testing

    by Raymond J. Roberge, Jung-Hyun Kim, Andrew Palmiero, Jeffrey B. Powell

    Workers required to wear respirators must undergo additional respirator fit testing if a significant change in body weight occurs. Approximately 10% of working women of reproductive age will be pregnant and experience a significant change in weight, yet the effect of pregnancy-associated weight gain on respirator fit is unknown. Cephalo-facial anthropometric measurements and quantitative fit testing of N95 filtering facepiece respirators (N95 FFR) of 15 pregnant women and 15 matched, non-pregnant women were undertaken for comparisons between the groups. There were no significant differences between pregnant and non-pregnant women with respect to cephalo-facial anthropometric measurements or N95 FFR quantitative fit tests. Healthy pregnant workers, who adhere to the recommended weight gain limits of pregnancy, are unlikely to experience an increase in cephalo-facial dimensions that would mandate additional N95 FFR fit testing above that which is normally required on an annual basis.


  • Open Access

    Pressure drop of filtering facepiece respirators: How low should we go?

    by Jung-Hyun Kim, Raymond J. Roberge, Jeffrey B. Powell, Ronald E. Shaffer, Caroline M. Ylitalo, John M. Sebastian

    Introduction: This study was undertaken to determine the mean peak filter resistance to airflow (Rfilter) encountered by subjects while wearing prototype filtering facepiece respirators (PRs) with low Rfilter during nasal and oral breathing at sedentary and low-moderate work rates. Material...


  • Open Access

    Effect of external airflow resistive load on postural and exercise-associated cardiovascular and pulmonary responses in pregnancy: a case control study

    by Jung-Hyun Kim, Raymond J Roberge, Jeffrey B Powell

    Facial coverings (e.g., balaclavas, niqabs, medical/surgical masks, respirators, etc.), that impose low levels of airflow resistive loads, are worn by millions of pregnant women worldwide, but little data exist addressing their impact on pregnancy-associated cardiovascular and pulmonary responses. 16 pregnant and 16 non-pregnant women were monitored physiologically (heart rate, blood pressure, mean arterial pressure, total peripheral resistance, stroke volume, cardiac output, oxygen saturation, transcutaneous carbon dioxide, fetal heart rate) and subjectively (exertion) for 1 h of mixed sedentary postural activity (sitting, standing) and moderate exercise (bicycle ergometer) with and without wearing N95 filtering facepiece respirators with filter resistive loads of 94.1 Pa (9.6 mm H2O) – 119.6 Pa (12.2 mm H2O) pressure. The external airflow resistive loads were associated with increases in diastolic pressure (p = 0.004), mean arterial pressure (p = 0.01), and subjective exertion score (p < 0.001) of all study subjects. No significant differences were noted with the external resistive loads between the pregnant and non-pregnant groups for any cardiovascular, pulmonary and subjective variable over 1 h. Low external airflow resistive loads, during combined sedentary postural activity and moderate exercise over 1 h, were associated with increases in the diastolic and mean arterial pressures of all study subjects, but pregnancy itself was not associated with any significant differences in physiologic or subjective responses to the external airway resistive loads utilized in the study.