Bench-to-bedside review: An approach to hemodynamic monitoring - Guyton at the bedside
Open Access
- 29 October 2012
- journal article
- review article
- Published by Springer Nature in Critical Care
- Vol. 16 (5) , 236-7
Abstract
Hemodynamic monitoring is used to identify deviations from hemodynamic goals and to assess responses to therapy. To accomplish these goals one must understand how the circulation is regulated. In this review I begin with an historical review of the work of Arthur Guyton and his conceptual understanding of the circulation and then present an approach by which Guyton's concepts can be applied at the bedside. Guyton argued that cardiac output and central venous pressure are determined by the interaction of two functions: cardiac function, which is determined by cardiac performance; and a return function, which is determined by the return of blood to the heart. This means that changes in cardiac output are dependent upon changes of one of these two functions or of both. I start with an approach based on the approximation that blood pressure is determined by the product of cardiac output and systemic vascular resistance and that cardiac output is determined by cardiac function and venous return. A fall in blood pressure with no change in or a rise in cardiac output indicates that a decrease in vascular resistance is the dominant factor. If the fall in blood pressure is due to a fall in cardiac output then the role of a change in the return function and cardiac function can be separated by the patterns of changes in central venous pressure and cardiac output. Measurement of cardiac output is a central component to this approach but until recently it was not easy to obtain and was estimated from surrogates. However, there are now a number of non-invasive devices that can give measures of cardiac output and permit the use of physiological principles to more rapidly appreciate the primary pathophysiology behind hemodynamic abnormalities and to provide directed therapy.Keywords
This publication has 30 references indexed in Scilit:
- Phenylephrine and Tangible BiasAnesthesia & Analgesia, 2011
- The Physiologic Implications of Isolated Alpha1 Adrenergic StimulationAnesthesia & Analgesia, 2011
- The Clinical Implications of Isolated Alpha1 Adrenergic StimulationAnesthesia & Analgesia, 2011
- Clinical review: Update on hemodynamic monitoring - a consensus of 16Critical Care, 2011
- Fluids after cardiac surgery: A pilot study of the use of colloids versus crystalloids*Critical Care Medicine, 2010
- A further analysis of why pulmonary venous pressure rises after the onset of LV dysfunctionJournal of Applied Physiology, 2009
- COUNTERPOINT: THE CLASSICAL GUYTON VIEW THAT MEAN SYSTEMIC PRESSURE, RIGHT ATRIAL PRESSURE, AND VENOUS RESISTANCE GOVERN VENOUS RETURN IS NOT CORRECTJournal of Applied Physiology, 2006
- Point:Counterpoint: The classical Guyton view that mean systemic pressure, right atrial pressure, and venous resistance govern venous return is/is not correctJournal of Applied Physiology, 2006
- Central venous pressure: A useful but not so simple measurementCritical Care Medicine, 2006
- Effects of nitroprusside on venous return and central blood volume in the absence and presence of acute heart failure.Circulation, 1980