Analysis of occupants’ exposure risk of cough-expelled droplets in the workspace with various mixing ventilation layouts
Open Access
- 18 August 2022
- journal article
- research article
- Published by Springer Nature in Experimental and Computational Multiphase Flow
- Vol. 4 (4) , 389-398
Abstract
This study numerically investigated the transport characteristics of the cough-expelled droplets and their corresponding exposure risk of each occupant under various mixing ventilation layouts. Transient simulations were conducted in a conference room, while pathogen-bearing droplets were released by a standing speaker. The results showed that droplet residues (< 40 µm) had a high potential to reach occupant’s breathing zone, among which the number fraction of aerosol residues (< 10 µm) could be nearly doubled compared with that of the rest droplet residues in the breathing zone. Occupants’ exposure risks were found very sensitive to the ventilation layouts. The strong ventilated flow could significantly promote droplet dispersions when those inlets were closely located to the infectious speaker, resulting in all occupants exposed to a considerable fraction of aerosols and droplets within a given exposure time of 300 s. The mixing ventilation layout did not have a consistent performance on restricting the pathogen spread and controlling the occupant’s exposure risk in an enclosed workspace. Its performance could be highly sensitive to the location of the infectious agent. Centralized vent layouts could provide relatively more consistent performance on removing droplets, whilst some local airflow recirculation with locked droplets were noticed.Keywords
This publication has 22 references indexed in Scilit:
- COVID-19 Outbreak Associated with Air Conditioning in Restaurant, Guangzhou, China, 2020Emerging Infectious Diseases, 2020
- World Health Organization declares global emergency: A review of the 2019 novel coronavirus (COVID-19)International Journal of Surgery, 2020
- Overall performance evaluation of underfloor air distribution system with different heights of return ventsEnergy and Buildings, 2017
- Evaluation of manikin simplification methods for CFD simulations in occupied indoor environmentsEnergy and Buildings, 2016
- Enhanced spread of expiratory droplets by turbulence in a cough jetBuilding and Environment, 2015
- Experimental investigation of the human convective boundary layer in a quiescent indoor environmentBuilding and Environment, 2014
- Flow dynamics and characterization of a coughIndoor Air, 2009
- Characterization of expiration air jets and droplet size distributions immediately at the mouth openingJournal of Aerosol Science, 2009
- Toward Understanding the Risk of Secondary Airborne Infection: Emission of Respirable PathogensJournal of Occupational and Environmental Hygiene, 2005
- COMPARISON OF DIFFERENTk-ε MODELS FOR INDOOR AIR FLOW COMPUTATIONSNumerical Heat Transfer, Part B: Fundamentals, 1995