Abstract
Aerosols of semivolatile organic compounds (SVOCs) pose significant health risks to workers in various occupational settings. Measuring human exposure to these aerosols requires a separate assessment of the contribution of particles and gases, which is not resolved by existing sampling techniques. Here, we investigate experimentally the performance of the Semivolatile Aerosol Dichotomous Sampler (SADS), proposed in previous studies, for sampling monodisperse liquid particles with aerodynamic diameters between 0.15 and 4.5 µm, corresponding to workplace aerosols. The measured sampling performances are compared to their theoretical counterparts computed by computational fluid dynamics. The effects of leakage rate, repeatability of the assembly, imprecision of the actually machined nozzle diameters and SADS parts misalignment are examined. The SADS assembly is found easily leaky, but consequences on sampling can be overcome when a prior leak test with leakage rate below 4 Pa.s-1 is passed. Variation of nozzle diameters in the range (-4.5 %, +3.7 %) with respect to nominal values affects marginally (<3 %) aerosol transmission efficiency, but sampling performance is little reproducible during successive SADS assemblies (CV=22.1 % for wall losses). Theoretically unpredicted large (40–46 %) wall losses are measured for particles larger than 2 µm, located mostly (80 %) on the external walls of the collection nozzle. Assembly repeatability issues and simulations of SADS parts misalignment effect by CFD suggest that these undesirable particle deposits are due to the mechanical backlashes of the assembly. Thus, the current design does not guarantee a nozzle misalignment of less than 5 % of the acceleration nozzle diameter, and other important geometric parameters are not further constrained. The promising theoretical sampling performance of the SADS for SVOCs aerosol larger than 1 µm thus falls short of expectations due to mechanical design issues that can be improved before possible field use.Keywords
All Related Versions
- Published version: Aerosol Research, 2 (1), 183.
This publication has 21 references indexed in Scilit:
- Revisiting the CFD modeling of a virtual impactor with inverted split ratio: Highlighting some determinants of representativenessJournal of Aerosol Science, 2022
- Oral bioaccessibility of semi-volatile organic compounds (SVOCs) in settled dust: A review of measurement methods, data and influencing factorsJournal of Hazardous Materials, 2018
- Oil mist collection and oil mist-to-gas conversion via dielectric barrier discharge at atmospheric pressureSeparation and Purification Technology, 2015
- Evaporation of Liquid Semi-Volatile Aerosols Collected on Fibrous FiltersAerosol Science and Technology, 2010
- Optimization of the Design of a Semivolatile Aerosol Dichotomous SamplerAerosol Science and Technology, 2010
- Monitoring and Reducing Exposure of Infants to Pollutants in House Dust2009
- A new measuring method to detect the emissions of metal working fluid mistJournal of Hazardous Materials, 2007
- Oil Mist Concentration: A Comparison of Sampling MethodsAIHA Journal, 1999
- Development of High Efficiency Virtual ImpactorsAerosol Science and Technology, 1988
- Virtual impactors: a theoretical study.Environmental Science & Technology, 1980