Raymond Olsen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Raymond Olsen has a total of 85 co-authors. Here are the top co-authors by number of shared publications:
Paal Molander
National Institute of Occupational Health, Oslo, Norway
17 shared publicationsSyvert Thorud
A National Institute of Occupational Health , Oslo , Norway
10 shared publicationsYngvar Thomassen
National Institute of Occupational Health, Oslo, Norway
8 shared publicationsElsa Lundanes
Department of Chemistry, University of Oslo, P.O. Box 1033 Blindern, Oslo, Norway
7 shared publicationsTyge Greibrokk
Department of Chemistry, University of Oslo, P.O. Box 1033 Blindern, N-0315 Oslo, Norway
7 shared publicationsSteinar Øvrebø
National Institute of Occupational Health, P.O. Box 8149 Dep, N-0033 Oslo, Norway
6 shared publications
Latest Publications
- Open Access
- 11 July 2025
- Published by Oxford University Press (OUP) in Annals of Work Exposures and Health
- Vol. 69 (8) , 868-882
Inflammatory responses of inhalable aerosols from powder food industry in THP-1 cells
Background: Occupational exposure to inhalable aerosols and airborne particles in the food production industry is associated with an increased risk of respiratory diseases, including asthma and chronic obstructive pulmonary disease (COPD). This study aims to investigate the inflammatory potential of inhalable aerosols collected from various food production environments and work tasks by assessing the concentrations of cytokines using an in vitro assay. Methods: The inflammatory response, as measured by the production of inflammatory cytokines tumor necrosis factor-alpha (TNF-α), interleukin 1β (IL-1β), IL-2, IL-4, IL-6, IL-8, IL-10, and IL-12, was determined using human macrophages derived from THP-1 monocytic cells. These cells were exposed to inhalable aerosol samples from 12 dry powder food processing plants. Cytokine concentrations were quantified using a Luminex assay. Results: This study identified statistically significant variations in in vitro cytokine responses across different production types and work tasks, emphasizing the diverse inflammatory potential of workplace aerosols. Furthermore, a dose-dependent relationship was observed for TNF-α, IL-8, IL-2, and IL-1β, suggesting that aerosol mass plays a role in immune activation. After normalizing cytokine concentrations to aerosol mass, variations in the intrinsic potential of aerosols were observed, indicating that aerosols generated during dry powder food production have differing capacities to induce an inflammatory response. Conclusions: This study has demonstrated that the inflammatory potential of inhalable aerosols collected from various food production environments can be assessed by measuring cytokine concentrations using an in vitro assay. Although cytokine concentrations were generally low, weighing and mixing food ingredients, and environments like coffee, spice, and powdered consumer product production, and bakeries exhibited elevated concentrations of inflammatory cytokines, potentially indicating a higher risk for workers in these settings.
- 11 July 2025
- Published by Oxford University Press (OUP) in Annals of Work Exposures and Health
- Vol. 69 (8) , 868-882
Open AccessInflammatory responses of inhalable aerosols from powder food industry in THP-1 cells
Background: Occupational exposure to inhalable aerosols and airborne particles in the food production industry is associated with an increased risk of respiratory diseases, including asthma and chronic obstructive pulmonary disease (COPD). This study aims to investigate the inflammatory potential of inhalable aerosols collected from various food production environments and work tasks by assessing the concentrations of cytokines using an in vitro assay. Methods: The inflammatory response, as measured by the production of inflammatory cytokines tumor necrosis factor-alpha (TNF-α), interleukin 1β (IL-1β), IL-2, IL-4, IL-6, IL-8, IL-10, and IL-12, was determined using human macrophages derived from THP-1 monocytic cells. These cells were exposed to inhalable aerosol samples from 12 dry powder food processing plants. Cytokine concentrations were quantified using a Luminex assay. Results: This study identified statistically significant variations in in vitro cytokine responses across different production types and work tasks, emphasizing the diverse inflammatory potential of workplace aerosols. Furthermore, a dose-dependent relationship was observed for TNF-α, IL-8, IL-2, and IL-1β, suggesting that aerosol mass plays a role in immune activation. After normalizing cytokine concentrations to aerosol mass, variations in the intrinsic potential of aerosols were observed, indicating that aerosols generated during dry powder food production have differing capacities to induce an inflammatory response. Conclusions: This study has demonstrated that the inflammatory potential of inhalable aerosols collected from various food production environments can be assessed by measuring cytokine concentrations using an in vitro assay. Although cytokine concentrations were generally low, weighing and mixing food ingredients, and environments like coffee, spice, and powdered consumer product production, and bakeries exhibited elevated concentrations of inflammatory cytokines, potentially indicating a higher risk for workers in these settings.
- Open Access
- 14 June 2024
- Published by Copernicus GmbH in Aerosol Research
- Vol. 2 (1) , 183-198
Performance evaluation of a semivolatile aerosol dichotomous sampler (SADS) for exposure assessment: impact of design issues
Aerosols of semivolatile organic compounds (SVOCs) pose significant health risks to workers in various occupational settings. Measuring human exposure to these aerosols requires a separate assessment of the contribution of particles and gases, which is not resolved by existing sampling techniques. Here, we investigate experimentally the performance of a semivolatile aerosol dichotomous sampler (SADS), proposed in previous studies, for sampling monodisperse liquid particles with aerodynamic diameters between 0.15 and 4.5 µm, corresponding to workplace aerosols. The measured sampling performances are compared to their theoretical counterparts computed by computational fluid dynamics. The effects of leakage rate, repeatability of the assembly, imprecision of the actually machined nozzle diameters, and SADS part misalignment are examined. The SADS assembly is found to be easily leaky, but consequences on sampling can be overcome when a prior leak test with a leakage rate below 4 Pa s−1 is passed. Variation of nozzle diameters in the range (−4.5 %, +3.7 %) with respect to nominal values affects marginally (< 3 %) aerosol transmission efficiency, but sampling performance is little reproducible during successive SADS assemblies (CV = 22.1 % for wall losses). Theoretically unpredicted large (40 %–46 %) wall losses are measured for particles larger than 2 µm, located mostly (80 %) on the external walls of the collection nozzle. Assembly repeatability issues and simulations of SADS parts misalignment effect by computational fluid dynamics (CFD) suggest that these undesirable particle deposits are due to the mechanical backlashes of the assembly. Thus, the current design does not guarantee a nozzle misalignment of less than 5 % of the acceleration nozzle diameter, and other important geometric parameters are not further constrained. The promising theoretical sampling performance of the SADS for SVOC aerosols larger than 1 µm thus falls short of expectations due to mechanical design issues that can be improved before possible field use.
- 14 June 2024
- Published by Copernicus GmbH in Aerosol Research
- Vol. 2 (1) , 183-198
Open AccessPerformance evaluation of a semivolatile aerosol dichotomous sampler (SADS) for exposure assessment: impact of design issues
Aerosols of semivolatile organic compounds (SVOCs) pose significant health risks to workers in various occupational settings. Measuring human exposure to these aerosols requires a separate assessment of the contribution of particles and gases, which is not resolved by existing sampling techniques. Here, we investigate experimentally the performance of a semivolatile aerosol dichotomous sampler (SADS), proposed in previous studies, for sampling monodisperse liquid particles with aerodynamic diameters between 0.15 and 4.5 µm, corresponding to workplace aerosols. The measured sampling performances are compared to their theoretical counterparts computed by computational fluid dynamics. The effects of leakage rate, repeatability of the assembly, imprecision of the actually machined nozzle diameters, and SADS part misalignment are examined. The SADS assembly is found to be easily leaky, but consequences on sampling can be overcome when a prior leak test with a leakage rate below 4 Pa s−1 is passed. Variation of nozzle diameters in the range (−4.5 %, +3.7 %) with respect to nominal values affects marginally (< 3 %) aerosol transmission efficiency, but sampling performance is little reproducible during successive SADS assemblies (CV = 22.1 % for wall losses). Theoretically unpredicted large (40 %–46 %) wall losses are measured for particles larger than 2 µm, located mostly (80 %) on the external walls of the collection nozzle. Assembly repeatability issues and simulations of SADS parts misalignment effect by computational fluid dynamics (CFD) suggest that these undesirable particle deposits are due to the mechanical backlashes of the assembly. Thus, the current design does not guarantee a nozzle misalignment of less than 5 % of the acceleration nozzle diameter, and other important geometric parameters are not further constrained. The promising theoretical sampling performance of the SADS for SVOC aerosols larger than 1 µm thus falls short of expectations due to mechanical design issues that can be improved before possible field use.
- Open Access
- 15 May 2024
- Published by Elsevier in Safety and Health at Work
- Vol. 15 (3) , 360-367
Assessment of Occupational Exposure to Inhalable Aerosols in an Instant Powdered Food Manufacturing Plant in Norway
- 15 May 2024
- Published by Elsevier in Safety and Health at Work
- Vol. 15 (3) , 360-367
Open AccessAssessment of Occupational Exposure to Inhalable Aerosols in an Instant Powdered Food Manufacturing Plant in Norway
- Open Access
- 22 January 2024
- Published by Copernicus GmbH in EGUsphere
- Vol. 2024, 1-23
Performance evaluation of a Semivolatile Aerosol Dichotomous Sampler (SADS) for Exposure Assessment: impact of design issues
Aerosols of semivolatile organic compounds (SVOCs) pose significant health risks to workers in various occupational settings. Measuring human exposure to these aerosols requires a separate assessment of the contribution of particles and gases, which is not resolved by existing sampling techniques. Here, we investigate experimentally the performance of the Semivolatile Aerosol Dichotomous Sampler (SADS), proposed in previous studies, for sampling monodisperse liquid particles with aerodynamic diameters between 0.15 and 4.5 µm, corresponding to workplace aerosols. The measured sampling performances are compared to their theoretical counterparts computed by computational fluid dynamics. The effects of leakage rate, repeatability of the assembly, imprecision of the actually machined nozzle diameters and SADS parts misalignment are examined. The SADS assembly is found easily leaky, but consequences on sampling can be overcome when a prior leak test with leakage rate below 4 Pa.s-1 is passed. Variation of nozzle diameters in the range (-4.5 %, +3.7 %) with respect to nominal values affects marginally (<3 %) aerosol transmission efficiency, but sampling performance is little reproducible during successive SADS assemblies (CV=22.1 % for wall losses). Theoretically unpredicted large (40–46 %) wall losses are measured for particles larger than 2 µm, located mostly (80 %) on the external walls of the collection nozzle. Assembly repeatability issues and simulations of SADS parts misalignment effect by CFD suggest that these undesirable particle deposits are due to the mechanical backlashes of the assembly. Thus, the current design does not guarantee a nozzle misalignment of less than 5 % of the acceleration nozzle diameter, and other important geometric parameters are not further constrained. The promising theoretical sampling performance of the SADS for SVOCs aerosol larger than 1 µm thus falls short of expectations due to mechanical design issues that can be improved before possible field use.
- 22 January 2024
- Published by Copernicus GmbH in EGUsphere
- Vol. 2024, 1-23
Open AccessPerformance evaluation of a Semivolatile Aerosol Dichotomous Sampler (SADS) for Exposure Assessment: impact of design issues
Aerosols of semivolatile organic compounds (SVOCs) pose significant health risks to workers in various occupational settings. Measuring human exposure to these aerosols requires a separate assessment of the contribution of particles and gases, which is not resolved by existing sampling techniques. Here, we investigate experimentally the performance of the Semivolatile Aerosol Dichotomous Sampler (SADS), proposed in previous studies, for sampling monodisperse liquid particles with aerodynamic diameters between 0.15 and 4.5 µm, corresponding to workplace aerosols. The measured sampling performances are compared to their theoretical counterparts computed by computational fluid dynamics. The effects of leakage rate, repeatability of the assembly, imprecision of the actually machined nozzle diameters and SADS parts misalignment are examined. The SADS assembly is found easily leaky, but consequences on sampling can be overcome when a prior leak test with leakage rate below 4 Pa.s-1 is passed. Variation of nozzle diameters in the range (-4.5 %, +3.7 %) with respect to nominal values affects marginally (<3 %) aerosol transmission efficiency, but sampling performance is little reproducible during successive SADS assemblies (CV=22.1 % for wall losses). Theoretically unpredicted large (40–46 %) wall losses are measured for particles larger than 2 µm, located mostly (80 %) on the external walls of the collection nozzle. Assembly repeatability issues and simulations of SADS parts misalignment effect by CFD suggest that these undesirable particle deposits are due to the mechanical backlashes of the assembly. Thus, the current design does not guarantee a nozzle misalignment of less than 5 % of the acceleration nozzle diameter, and other important geometric parameters are not further constrained. The promising theoretical sampling performance of the SADS for SVOCs aerosol larger than 1 µm thus falls short of expectations due to mechanical design issues that can be improved before possible field use.
- 1 September 2020
- Published by Elsevier in Toxicology Letters
- Vol. 329, 20-25
Biomonitoring of the benzene metabolite s-phenylmercapturic acid and the toluene metabolite s-benzylmercapturic acid in urine from firefighters
- 1 September 2020
- Published by Elsevier in Toxicology Letters
- Vol. 329, 20-25
Biomonitoring of the benzene metabolite s-phenylmercapturic acid and the toluene metabolite s-benzylmercapturic acid in urine from firefighters
- 1 September 2019
- Published by Elsevier in Science of The Total Environment
- Vol. 681, 533-540
Occupational exposure during treatment of offshore drilling waste and characterization of microbiological diversity
- 1 September 2019
- Published by Elsevier in Science of The Total Environment
- Vol. 681, 533-540
Occupational exposure during treatment of offshore drilling waste and characterization of microbiological diversity
- Open Access
- 23 January 2019
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 16 (3) , 300
Pneumoproteins in Offshore Drill Floor Workers
The aim was to assess pneumoproteins and a certain biomarker of systemic inflammation in drill floor workers exposed to airborne contaminants generated during drilling offshore, taking into consideration serum biomarkers of smoking, such as nicotine (S-Nico) and cotinine. Blood samples of club cell protein 16 (CC-16), surfactant protein D (SP-D) and C-reactive protein (CRP) were collected before and after a 14-day work period from 65 drill floor workers and 65 referents. Air samples of oil mist, drilling mud components and elemental carbon were collected in person. The drill floor workers were exposed to a median air concentration of 0.18 mg/m3 of oil mist and 0.14 mg/m3 of airborne mud particles. There were no differences in the concentrations of CC-16 and SP-D across the 14-day work period and no difference between drill floor workers and referents at baseline after adjusting for differences in sampling time and smoking. CRP decreased across the work period. There was a strong association between the CC-16 concentrations and the time of sampling. Current smokers with S-Nico > detection limit (DL) had a statistically significantly lower CC-16 concentration, while smokers with S-Nico < DL had CC-16 concentrations similar to that of the non-smokers. Fourteen days of work offshore had no effect on serum pneumoprotein and CRP concentrations. However, the time of blood sampling was observed to have a strong effect on the measured concentrations of CC-16. The effect of current smoking on the CC-16 concentrations appears to be dependent on the S-Nico concentrations.
- 23 January 2019
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 16 (3) , 300
Open AccessPneumoproteins in Offshore Drill Floor Workers
The aim was to assess pneumoproteins and a certain biomarker of systemic inflammation in drill floor workers exposed to airborne contaminants generated during drilling offshore, taking into consideration serum biomarkers of smoking, such as nicotine (S-Nico) and cotinine. Blood samples of club cell protein 16 (CC-16), surfactant protein D (SP-D) and C-reactive protein (CRP) were collected before and after a 14-day work period from 65 drill floor workers and 65 referents. Air samples of oil mist, drilling mud components and elemental carbon were collected in person. The drill floor workers were exposed to a median air concentration of 0.18 mg/m3 of oil mist and 0.14 mg/m3 of airborne mud particles. There were no differences in the concentrations of CC-16 and SP-D across the 14-day work period and no difference between drill floor workers and referents at baseline after adjusting for differences in sampling time and smoking. CRP decreased across the work period. There was a strong association between the CC-16 concentrations and the time of sampling. Current smokers with S-Nico > detection limit (DL) had a statistically significantly lower CC-16 concentration, while smokers with S-Nico < DL had CC-16 concentrations similar to that of the non-smokers. Fourteen days of work offshore had no effect on serum pneumoprotein and CRP concentrations. However, the time of blood sampling was observed to have a strong effect on the measured concentrations of CC-16. The effect of current smoking on the CC-16 concentrations appears to be dependent on the S-Nico concentrations.
- Open Access
- 24 April 2018
- Published by BMJ
- Vol. 75, A524
718 Tremor measurements in a twenty-two year longitudinal study of workers exposed to hand-held vibrating tools
Background Use of hand-held vibrating tools may lead to hand-arm vibration syndrome (HAVS), which is composed of vascular, neurological and muscular components. Few studies have investigated possible long-term effects on tremor related to hand-held vibrating tools. Objectives The objectives were to evaluate postural and rest hand tremor in workers with current and previous exposure to vibrating hand tools, taking into account the possible effects from medical conditions and life-style habits such as tobacco and alcohol consumption. Subjects and methods Forty workers previously employed in a specialised engineering and construction company were examined with a test-battery and a clinical examination in 1994 and 2017. Age at last examination was 60.7 years (44.6 to 77.8 years). Hand tremor was measured in 2016/2017 with the Tremor Pen from CATSYS. Their exposure to hand-held vibrating tools was assessed as acceleration x lifetime exposure. Biological samples of Carbohydrate-deficient transferrin (CDT), glycated haemoglobin (HbA1c), cotinine, nicotine and caffeine were collected on the day of examination. Results The data collection was finished by ultimo March 2017. Preliminary results indicate that tobacco consumption assessed by cotinine in serum and diabetes assessed by HbA1c were more closely associated with tremor parameters than lifetime exposure to hand-held vibrating tools. For all subjects the magnitude of the tremor, the tremor Intensity, was 0.15 and 0.13 ms-2 for the dominant and non-dominant hands respectively. The hand position is important when testing for tremor. When postural and rest tremor measures were compared, the frequency of the tremor increased significantly, from 7.4 to 9.8 Hz and from 7.6 to 9.3 Hz for the dominant and non-dominant hands respectively.
- 24 April 2018
- Published by BMJ
- Vol. 75, A524
Open Access718 Tremor measurements in a twenty-two year longitudinal study of workers exposed to hand-held vibrating tools
Background Use of hand-held vibrating tools may lead to hand-arm vibration syndrome (HAVS), which is composed of vascular, neurological and muscular components. Few studies have investigated possible long-term effects on tremor related to hand-held vibrating tools. Objectives The objectives were to evaluate postural and rest hand tremor in workers with current and previous exposure to vibrating hand tools, taking into account the possible effects from medical conditions and life-style habits such as tobacco and alcohol consumption. Subjects and methods Forty workers previously employed in a specialised engineering and construction company were examined with a test-battery and a clinical examination in 1994 and 2017. Age at last examination was 60.7 years (44.6 to 77.8 years). Hand tremor was measured in 2016/2017 with the Tremor Pen from CATSYS. Their exposure to hand-held vibrating tools was assessed as acceleration x lifetime exposure. Biological samples of Carbohydrate-deficient transferrin (CDT), glycated haemoglobin (HbA1c), cotinine, nicotine and caffeine were collected on the day of examination. Results The data collection was finished by ultimo March 2017. Preliminary results indicate that tobacco consumption assessed by cotinine in serum and diabetes assessed by HbA1c were more closely associated with tremor parameters than lifetime exposure to hand-held vibrating tools. For all subjects the magnitude of the tremor, the tremor Intensity, was 0.15 and 0.13 ms-2 for the dominant and non-dominant hands respectively. The hand position is important when testing for tremor. When postural and rest tremor measures were compared, the frequency of the tremor increased significantly, from 7.4 to 9.8 Hz and from 7.6 to 9.3 Hz for the dominant and non-dominant hands respectively.
- Open Access
- 7 February 2018
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Processes & Impacts
- Vol. 20 (2) , 417
Correction: Comparison of air samplers for determination of isocyanic acid and applicability for work environment exposure assessment
Correction for ‘Comparison of air samplers for determination of isocyanic acid and applicability for work environment exposure assessment’ by Mikolaj Jan Jankowski et al., Environ. Sci.: Processes Impacts, 2017, 19, 1075–1085.
- 7 February 2018
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Processes & Impacts
- Vol. 20 (2) , 417
Open AccessCorrection: Comparison of air samplers for determination of isocyanic acid and applicability for work environment exposure assessment
Correction for ‘Comparison of air samplers for determination of isocyanic acid and applicability for work environment exposure assessment’ by Mikolaj Jan Jankowski et al., Environ. Sci.: Processes Impacts, 2017, 19, 1075–1085.
- Open Access
- 7 February 2018
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Processes & Impacts
- Vol. 20 (2) , 416
Correction: The stability and generation pattern of thermally formed isocyanic acid (ICA) in air – potential and limitations of proton transfer reaction-mass spectrometry (PTR-MS) for real-time workroom atmosphere measurements
Correction for ‘The stability and generation pattern of thermally formed isocyanic acid (ICA) in air – potential and limitations of proton transfer reaction-mass spectrometry (PTR-MS) for real-time workroom atmosphere measurements’ by Mikolaj Jan Jankowski et al., Environ. Sci.: Processes Impacts, 2016, 18, 810–818.
- 7 February 2018
- Published by Royal Society of Chemistry (RSC) in Environmental Science: Processes & Impacts
- Vol. 20 (2) , 416
Open AccessCorrection: The stability and generation pattern of thermally formed isocyanic acid (ICA) in air – potential and limitations of proton transfer reaction-mass spectrometry (PTR-MS) for real-time workroom atmosphere measurements
Correction for ‘The stability and generation pattern of thermally formed isocyanic acid (ICA) in air – potential and limitations of proton transfer reaction-mass spectrometry (PTR-MS) for real-time workroom atmosphere measurements’ by Mikolaj Jan Jankowski et al., Environ. Sci.: Processes Impacts, 2016, 18, 810–818.