Abstract
Purpose. To evaluate the actual efficiency of a supply and exhaust ventilation unit with heat recovery under real operating conditions of an educational room during the heating period, to obtain the dependencies of its performance indicators on the outdoor air temperature and to quantify the influence of the frost protection algorithm on the achievable level of heat utilization. Method. A full-scale experiment was carried out on a Vents VUT 300 PB EC P A21 DTV unit with a counter-flow polymer heat exchanger installed in a computer classroom of the National University “Yuri Kondratyuk Poltava Polytechnic”. A hardware and software monitoring complex was created, including the built-in temperature sensors of the unit read every 2 minutes by the specially developed ModbusReader application, a Sonoff POWR316D Wi-Fi electricity meter with the eWeLink application, a Sencor SWS12500WIFI weather station and three Xintest HT-501 indoor climate sensors. During the heating period, at outdoor temperatures from minus 9.7 to 12.7 degrees Celsius, an array of 5267 synchronized records was formed; after averaging over 10-minute intervals and sorting by outdoor temperature it contained 1059 points. The recovery effectiveness was determined by the temperature method, and third-degree polynomial regression was applied separately to the two operating modes of the unit. Results. It was established that the boundary between the two qualitatively different operating modes is about minus 2.7 degrees Celsius. Below this temperature the frost protection algorithm limited the full operation of the unit to 51.3 percent of the time: the average recovery effectiveness in this mode was about 52 percent, which corresponds to an effective heat utilization of about 27 percent, while in the normal mode the average effectiveness reached 86 percent with peaks up to 97 percent. The average recovered heat capacity was 0.85 kW in the frost protection mode and 1.26 kW in the normal mode, the ratio of the recovered heat capacity to the consumed electric power was on average 7.8 and 2.9 respectively, reaching 18. The recovered heat capacity over the whole period varied within 0.23–1.68 kW, and in the normal mode it naturally decreased with the increase of the outdoor air temperature. Scientific novelty. For the first time, on the basis of long-term automated monitoring of a serial small-capacity unit in the climatic conditions of Ukraine, the influence of the frost protection algorithm was quantified and polynomial regression dependencies of the performance indicators on the outdoor air temperature were obtained separately for the two operating modes. Practical importance. The obtained dependencies and indicators can be used in technical and economic feasibility calculations of heat recovery ventilation in educational buildings, in the selection of operating modes of such units, and the described monitoring approach can be reproduced for other objects.

This publication has 10 references indexed in Scilit: