Application of ultrasound dilution technology for cardiac output measurement: Cerebral and systemic hemodynamic consequences in a juvenile animal model
Authors:
- Willem P. de BoodeWBWillem P. de Boode
- Arno F. J. van HeijstAHArno F. J. van Heijst
- Jeroen C. W. HopmanJHJeroen C. W. Hopman
- Ronald B. TankeRTRonald B. Tanke
- Hans G. van der HoevenHHHans G. van der Hoeven
- K. Djien LiemKLK. Djien Liem
- 1 September 2010
- journal article
- Published by Wolters Kluwer Health in Pediatric Critical Care Medicine
- Vol. 11 (5) , 616-623
Abstract
Analysis of cerebral and systemic hemodynamic consequences of ultrasound dilution cardiac output measurements. : Prospective, experimental piglet study. Animal laboratory. Nine piglets. Ultrasound dilution cardiac output measurements were performed in ventilated, anesthetized piglets. Interventions that are required for ultrasound dilution cardiac output measurement were evaluated for its effect on cerebral and systemic circulation and oxygenation. DeltacHbD and DeltactHb, representing changes in cerebral blood flow and cerebral blood volume, respectively, were measured with near infrared spectrophotometry. Pulmonary artery (Q) and left carotid artery (Q) blood flow were assessed with transit time flow probes. Starting and/or stopping blood flowing through the arteriovenous loop did not cause relevant hemodynamic changes. Fast injection of isotonic saline caused a biphasic change in DeltacHbD and DeltactHb. After injection of 0.5 mL/kg, the mean (sd) increase in DeltacHbD and DeltactHb was 0.175 (0.213) micromol/L and 0.122 (0.148) micromol/L, respectively, with a subsequent mean decrease of -0.191 (0.299) micromol/L and -0.312 (0.266) micromol/L. Injection of 1.0 mL/kg caused a mean increase in DeltacHbD and DeltactHb of 0.237 (0.203) micromol/L and 0.179 (0.162) followed by a mean decrease of -0.334 (0.407) micromol/L and -0.523 (0.335) micromol/L, respectively. Q and Q changed shortly with a mean increase of 5.9 (3.0) mL/kg/min and 0.23 (0.10) mL/kg/min after injection of 0.5 mL/kg and with 12.0 (4.2) mL/kg/min and 0.44 (0.18) mL/kg/min after injection of 1.0 mL/kg, respectively. The observed changes were more profound after an injection volume of 1.0 mL/kg compared with 0.5 mL/kg for DeltacHbD (p = .06), DeltactHb (p = .09), Q, and Q (p < .01). No relevant changes in mean arterial blood pressure or heart rate were detected in response to the indicator injection. Cardiac output measurement by ultrasound dilution does not cause clinically relevant changes in cerebral and systemic circulation and oxygenation in a piglet model.Keywords
This publication has 30 references indexed in Scilit:
- Theory and in vitro validation of a new extracorporeal arteriovenous loop approach for hemodynamic assessment in pediatric and neonatal intensive care unit patients*Pediatric Critical Care Medicine, 2008
- Minimally invasive cardiac output monitoringCurrent Opinion in Critical Care, 2008
- Cardiac output monitoringAnnals of Cardiac Anaesthesia, 2008
- Blood sampling via umbilical vein catheters decreases cerebral oxygenation and blood volume in preterm infantsActa Paediatrica, 2007
- What technique should I use to measure cardiac output?Current Opinion in Critical Care, 2007
- Umbilical artery catheter blood sampling volume and velocity: Impact on cerebral blood volume and oxygenation in very-low-birthweight infantsActa Paediatrica, 2006
- Minimally invasive hemodynamic monitoring for the intensivist: Current and emerging technologyCritical Care Medicine, 2002
- Umbilical artery catheter blood sampling decreases cerebral blood volume and oxygenation in very low birthweight infantsActa Paediatrica, 2000
- Extracorporeal Recording of Mouse Hemodynamic Parameters by Ultrasound Velocity DilutionASAIO Journal, 1999
- Novel Method to Measure Access Flow During Hemodialysis by Ultrasound Velocity Dilution TechniqueASAIO Journal, 1995