An efficient Monte Carlo-based algorithm for scatter correction in keV cone-beam CT
- 2 June 2009
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 54 (12) , 3847-3864
Abstract
A new method is proposed for scatter-correction of cone-beam CT images. A coarse reconstruction is used in initial iteration steps. Modelling of the x-ray tube spectra and detector response are included in the algorithm. Photon diffusion inside the imaging subject is calculated using the Monte Carlo method. Photon scoring at the detector is calculated using forced detection to a fixed set of node points. The scatter profiles are then obtained by linear interpolation. The algorithm is referred to as the coarse reconstruction and fixed detection (CRFD) technique. Scatter predictions are quantitatively validated against a widely used general-purpose Monte Carlo code: BEAMnrc/EGSnrc (NRCC, Canada). Agreement is excellent. The CRFD algorithm was applied to projection data acquired with a Synergy XVI CBCT unit (Elekta Limited, Crawley, UK), using RANDO and Catphan phantoms (The Phantom Laboratory, Salem NY, USA). The algorithm was shown to be effective in removing scatter-induced artefacts from CBCT images, and took as little as 2 min on a desktop PC. Image uniformity was greatly improved as was CT-number accuracy in reconstructions. This latter improvement was less marked where the expected CT-number of a material was very different to the background material in which it was embedded.Keywords
This publication has 31 references indexed in Scilit:
- Characteristics of kilovoltage x-ray beams used for cone-beam computed tomography in radiation therapyPhysics in Medicine & Biology, 2007
- Characterization of scattered radiation in kV CBCT images using Monte Carlo simulationsMedical Physics, 2006
- Accelerated Simulation of Cone Beam X-Ray Scatter ProjectionsIEEE Transactions on Medical Imaging, 2004
- Flat-panel cone-beam computed tomography for image-guided radiation therapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2002
- Cone-beam CT from width-truncated projectionsComputerized Medical Imaging and Graphics, 1996
- Programs to generate Niederreiter's low-discrepancy sequencesACM Transactions on Mathematical Software, 1994
- A review of pseudorandom number generatorsComputer Physics Communications, 1990
- Physical characteristics of scattered radiation in diagnostic radiology: Monte Carlo simulation studiesMedical Physics, 1985
- Practical cone-beam algorithmJournal of the Optical Society of America A, 1984
- Atomic form factors, incoherent scattering functions, and photon scattering cross sectionsJournal of Physical and Chemical Reference Data, 1975