  • Technical Note: Suppression of artifacts arising from simultaneous cone-beam imaging and RF transponder tracking in prostate radiotherapy

    by Gavin Poludniowski, Steve Webb, Philip M. Evans

    Purpose: Artifacts in treatment‐room cone‐beam reconstructions have been observed at the authors' center when cone‐beam acquisition is simultaneous with radio frequency (RF) transponder tracking using the Calypso 4D system (Calypso Medical, Seattle, WA). These artifacts manifest as CT‐number modulations and increased CT‐noise. The authors present a method for the suppression of the artifacts. Methods: The authors propose a three‐stage postprocessing technique that can be applied to image volumes previously reconstructed by a cone‐beam system. The stages are (1) segmentation of voxels into air, soft‐tissue, and bone; (2) application of a 2D spatial‐filter in the axial plane to the soft‐tissue voxels; and (3) normalization to remove streaking along the axial‐direction. The algorithm was tested on patient data acquired with Synergy XVI cone‐beam CT systems (Elekta, Crawley, United Kingdom). Results: The computational demands of the suggested correction are small, taking less than 15 s per cone‐beam reconstruction on a desktop PC. For a moderate loss of spatial‐resolution, the artifacts are strongly suppressed and low‐contrast visibility is improved. Conclusions: The correction technique proposed is fast and effective in removing the artifacts caused by simultaneous cone‐beam imaging and RF‐transponder tracking.


  • Removal and effects of scatter-glare in cone-beam CT with an amorphous-silicon flat-panel detector

    by G Poludniowski, P M Evans, A Kavanagh, S Webb

    Scatter in a detector and its housing can result in image degradation. Typically, such scatter leads to a low-spatial frequency ‘glare’ superimposed on the primary signal. We infer the glare-spread function (GSF) of an amorphous-silicon flat-panel detector via an edge-spread technique. We demonstrate that this spread (referred to as ‘scatter-glare’ herein) causes a low-spatial frequency drop in the associated modulation-transfer function. This results in a compression of the range of reconstructed CT (computed tomography) numbers and is an impediment to accurate CT-number calibration. We show that it can also lead to visual artefacts. This explains previously unresolved CT-number discrepancies in an earlier work (Poludniowski et al 2009 Phys. Med. Biol. 54 3847). We demonstrate that after deconvolving the GSF from the projection images, in conjunction with a correction for phantom-scatter, the CT-number discrepancies disappear. We show results for an in-house-built phantom with inserts of tissue-equivalent materials and for a patient scan. We conclude that where scatter-glare has not been accounted for, the calibration of cone-beam CT numbers to material density will be compromised. The scatter-glare measurement method we propose is simple and requires no special equipment. The deconvolution process is also straightforward and relatively quick (60 ms per projection on a desktop PC).


  • CT reconstruction from portal images acquired during volumetric-modulated arc therapy

    by G Poludniowski, M D R Thomas, P M Evans, S Webb

    Volumetric-modulated arc therapy (VMAT), a form of intensity-modulated arc therapy (IMAT), has become a topic of research and clinical activity in recent years. As a form of arc therapy, portal images acquired during the treatment fraction form a (partial) Radon transform of the patient. We show that these portal images, when used in a modified global cone-beam filtered backprojection (FBP) algorithm, allow a surprisingly recognizable CT-volume to be reconstructed. The possibility of distinguishing anatomy in such VMAT-CT reconstructions suggests that this could prove to be a valuable treatment position-verification tool. Further, some potential for local-tomography techniques to improve image quality is shown.


  • Rayleigh scatter in kilovoltage x-ray imaging: is the independent atom approximation good enough?

    by G Poludniowski, P M Evans, S Webb

    Monte Carlo simulation is the gold standard method for modelling scattering processes in medical x-ray imaging. General-purpose Monte Carlo codes, however, typically use the independent atom approximation (IAA). This is known to be inaccurate for Rayleigh scattering, for many materials, in the forward direction. This work addresses whether the IAA is sufficient for the typical modelling tasks in medical kilovoltage x-ray imaging. As a means of comparison, we incorporate a more realistic 'interference function' model into a custom-written Monte Carlo code. First, we conduct simulations of scatter from isolated voxels of soft tissue, adipose, cortical bone and spongiosa. Then, we simulate scatter profiles from a cylinder of water and from phantoms of a patient's head, thorax and pelvis, constructed from diagnostic-quality CT data sets. Lastly, we reconstruct CT numbers from simulated sets of projection images and investigate the quantitative effects of the approximation. We show that the IAA can produce errors of several per cent of the total scatter, across a projection image, for typical x-ray beams and patients. The errors in reconstructed CT number, however, for the phantoms simulated, were small (typically < 10 HU). The IAA can therefore be considered sufficient for the modelling of scatter correction in CT imaging. Where accurate quantitative estimates of scatter in individual projection images are required, however, the appropriate interference functions should be included.


  • Top Cited Papers

    SpekCalc: a program to calculate photon spectra from tungsten anode x-ray tubes

    by G Poludniowski, G Landry, F DeBlois, P M Evans, F Verhaegen

    A software program, SpekCalc, is presented for the calculation of x-ray spectra from tungsten anode x-ray tubes. SpekCalc was designed primarily for use in a medical physics context, for both research and education purposes, but may also be of interest to those working with x-ray tubes in industry. Noteworthy is the particularly wide range of tube potentials (40-300 kVp) and anode angles (recommended: 6-30 degrees) that can be modelled: the program is therefore potentially of use to those working in superficial/orthovoltage radiotherapy, as well as diagnostic radiology. The utility is free to download and is based on a deterministic model of x-ray spectrum generation (Poludniowski 2007 Med. Phys. 34 2175). Filtration can be applied for seven materials (air, water, Be, Al, Cu, Sn and W). In this note SpekCalc is described and illustrative examples are shown. Predictions are compared to those of a state-of-the-art Monte Carlo code (BEAMnrc) and, where possible, to an alternative, widely-used, spectrum calculation program (IPEM78).


  • An efficient Monte Carlo-based algorithm for scatter correction in keV cone-beam CT

    by G Poludniowski, P M Evans, V N Hansen, S Webb

    A new method is proposed for scatter-correction of cone-beam CT images. A coarse reconstruction is used in initial iteration steps. Modelling of the x-ray tube spectra and detector response are included in the algorithm. Photon diffusion inside the imaging subject is calculated using the Monte Carlo method. Photon scoring at the detector is calculated using forced detection to a fixed set of node points. The scatter profiles are then obtained by linear interpolation. The algorithm is referred to as the coarse reconstruction and fixed detection (CRFD) technique. Scatter predictions are quantitatively validated against a widely used general-purpose Monte Carlo code: BEAMnrc/EGSnrc (NRCC, Canada). Agreement is excellent. The CRFD algorithm was applied to projection data acquired with a Synergy XVI CBCT unit (Elekta Limited, Crawley, UK), using RANDO and Catphan phantoms (The Phantom Laboratory, Salem NY, USA). The algorithm was shown to be effective in removing scatter-induced artefacts from CBCT images, and took as little as 2 min on a desktop PC. Image uniformity was greatly improved as was CT-number accuracy in reconstructions. This latter improvement was less marked where the expected CT-number of a material was very different to the background material in which it was embedded.


  • Top Cited Papers

    Calculation of x‐ray spectra emerging from an x‐ray tube. Part II. X‐ray production and filtration in x‐ray targets

    by Gavin G. Poludniowski

    A new approach to the calculation of the x‐ray spectrum emerging from an x‐ray tube is proposed. Theoretical results for the bremsstrahlung cross section appearing in the literature are summarized. Four different treatments of electron penetration, based on the work presented in Part I, are then used to generate bremsstrahlung spectra. These spectra are compared to experimental data at 50, 80 and tube potentials. The most sophisticated treatment of electron penetration was required to obtain good agreement. With this treatment both the National Institute of Standards and Technology bremsstrahlung cross sections, based on accurate partial wave calculations, and the Bethe‐Heitler cross section [H. A. Bethe and W. Heitler, Proc R. Soc. London, Ser. A. 146, 83–112 (1934)] corrected by a modified Elwert factor [G. Elwert, Ann. Phys. (Leipzig) 426, 178–208 (1939)], provided good agreement to measured data. An approximate treatment of the characteristic spectrum is suggested. The dependencies of the bremsstrahlung and characteristic outputs of an x‐ray tube on tube potential are compared to experimentally derived data for 70– potentials. Agreement is to within a few percent of the total output over the entire range. The spectral predictions of the semiempirical models of Birch and Marshall [R. Birch and M. Marshall, Phys. Med. Biol. 24, 505–513 (1979)] (IPEM Report 78) and of Tucker et al. [D. M. Tucker, G. T. Barnes, and D. P. Chakraborty, Med. Phys. 18, 211–218 (1991).] are also assessed. The predictions of Tucker et al. are very close to the model developed here. The predictions of IPEM Report 78 are similar, but consistently harder for the range of tube potentials examined ). Unlike the semiempirical models, the model proposed here requires the introduction of no empirical and unphysical parameters in the differential bremsstrahlung cross section, bar an overall normalization factor which is close to unity.


  • Top Cited Papers

    Calculation of x‐ray spectra emerging from an x‐ray tube. Part I. Electron penetration characteristics in x‐ray targets

    by Gavin G. Poludniowski, Philip M. Evans

    The penetration characteristics of electron beams into x‐ray targets are investigated for incident electron kinetic energies in the range . The frequency densities of electrons penetrating to a depth in a target, with a fraction of initial kinetic energy, , are calculated using Monte Carlo methods for beam energies of 50, 80, 100, 120 and in a tungsten target. The frequency densities for electrons in Al, Mo and Re targets are also calculated. A mixture of simple modeling with equations and interpolation from data is used to generalize the calculations in tungsten. Where possible, parameters derived from the Monte Carlo data are compared to experimental measurements. Previous electron transport approximations in the semiempirical models of other authors are discussed and related to this work. In particular, the crudity of the use of the Thomson‐Whiddington law to describe electron penetration and energy loss is highlighted. The results presented here may be used towards calculating the target self‐attenuation correction for bremsstrahlung photons emitted within a tungsten target.