Multicenter Evaluation of the QIAstat‐Dx and the BioFire Multiplex Panel Tests for the Detection of Respiratory Pathogens
Open Access
- 23 December 2024
- journal article
- research article
- Published by Wiley in Journal of Medical Virology
- Vol. 96 (12) , e70129
Abstract
Syndromic multiplex panel testing enables simultaneous detection of multiple respiratory pathogens, but limited data is available on the comparative diagnostic performance of different testing systems. In this multicenter prospective study, we aimed to compare the QIAstat‐Dx Respiratory Panel 2.0 (QIAstat‐Dx‐RP2.0) with the widely used BioFire‐RP2.1, using 269 respiratory clinical specimens. Concordant test results were obtained in 232 (86.3%) cases. Discordant test results included 33 BioFire‐RP2.1(+)/QIAstat‐Dx‐RP2.0(−) and 4 BioFire‐RP2.1(‐)/QIAstat‐Dx‐RP2.0(+) results. Discordant samples showed significantly lower pathogen loads than concordant ones (p < 0.01). Overall, the QIAstat‐Dx‐RP2.0 showed an analytical sensitivity of 50%–100% depending on the respiratory target, with an analytical specificity ≥ 99.0%. Most significant differences were found for the detection of adenovirus, human coronaviruses, respiratory syncytial virus, human rhinovirus/enterovirus and SARS‐CoV‐2 (kappa‐score: 0.67–0.91). Co‐detections of respiratory pathogens were identified in 47 cases by BioFire‐RP2.1 and 29 by QIAstat‐Dx‐RP2.0. Agreement rates between the two multiplex panel tests decreased from 91.8% for single pathogen detections to 65.0% and 42.9% for co‐detecting two and three pathogens, respectively. Pathogen loads were significantly lower in co‐detections compared to single pathogen detections (p < 0.01), potentially explaining the lower detection rates with the QIAstat‐Dx‐RP2.0 in cases of multiple pathogens. In conclusion, our prospective multicenter evaluation showed good diagnostic performance of the QIAstat‐Dx‐RP2.0 assay, but lower detection rates for some respiratory targets compared to BioFire‐RP2.1. As QIAstat‐Dx‐RP2.0 offers advantages in handling, noise emission, cost effectiveness, and provides semi‐quantitative results compared to BioFire‐RP2.1 an updated version with enhanced analytical sensitivity would be a viable alternative syndromic testing system for detecting respiratory pathogens.Keywords
This publication has 36 references indexed in Scilit:
- Real-time PCR assays compared to culture-based approaches for identification of aerobic bacteria in chronic woundsClinical Microbiology and Infection, 2010
- High prevalence of human rhinovirus C infection in Thai children with acute lower respiratory tract diseaseJournal of Infection, 2009
- Outcome of influenza infections in outpatients after allogeneic hematopoietic stem cell transplantationTransplant Infectious Disease, 2009
- Respiratory Viruses Other than Influenza Virus: Impact and Therapeutic AdvancesClinical Microbiology Reviews, 2008
- Respiratory Syncytial Virus Infection in Patients with Hematological Diseases: Single-Center Study and Review of the LiteratureClinical Infectious Diseases, 2008
- Diagnosis of human metapneumovirus and rhinovirus in patients with respiratory tract infections by an internally controlled multiplex real-time RNA PCRJournal of Clinical Virology, 2005
- Improved Diagnosis of the Etiology of Community-Acquired Pneumonia with Real-Time Polymerase Chain ReactionClinical Infectious Diseases, 2005
- Rapid and Sensitive Method Using Multiplex Real-Time PCR for Diagnosis of Infections by Influenza A and Influenza B Viruses, Respiratory Syncytial Virus, and Parainfluenza Viruses 1, 2, 3, and 4Journal of Clinical Microbiology, 2004
- Excessive Antibiotic Use for Acute Respiratory Infections in the United StatesClinical Infectious Diseases, 2001
- The Measurement of Observer Agreement for Categorical DataBiometrics, 1977