Rainer Gosert
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Rainer Gosert has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Hans Hellmuth Hirsch
Translational Virus Immunity Pathology, Immunology Research, Department of Medical Biology UiT The Arctic University of Norway Tromsø Norway
5 shared publications - Karoline Leuzinger
Clinical Virology University Hospital Basel Basel Switzerland
2 shared publications - Klaudia Naegele
Clinical Virology, Laboratory Medicine, University Hospital Basel
2 shared publications Alban Ramette
Institute for Infectious Diseases University of Bern Bern Switzerland
1 shared publicationChristian H. Nickel
Emergency Medicine University Hospital Basel Basel Switzerland
1 shared publicationDenise Egger
Institute for Medical Microbiology, University of Basel, Basel, Switzerland
1 shared publication
Latest Publications
- Open Access
- 23 December 2024
- Published by Wiley in Journal of Medical Virology
- Vol. 96 (12) , e70129
Multicenter Evaluation of the QIAstat‐Dx and the BioFire Multiplex Panel Tests for the Detection of Respiratory Pathogens
Syndromic multiplex panel testing enables simultaneous detection of multiple respiratory pathogens, but limited data is available on the comparative diagnostic performance of different testing systems. In this multicenter prospective study, we aimed to compare the QIAstat‐Dx Respiratory Panel 2.0 (QIAstat‐Dx‐RP2.0) with the widely used BioFire‐RP2.1, using 269 respiratory clinical specimens. Concordant test results were obtained in 232 (86.3%) cases. Discordant test results included 33 BioFire‐RP2.1(+)/QIAstat‐Dx‐RP2.0(−) and 4 BioFire‐RP2.1(‐)/QIAstat‐Dx‐RP2.0(+) results. Discordant samples showed significantly lower pathogen loads than concordant ones (p < 0.01). Overall, the QIAstat‐Dx‐RP2.0 showed an analytical sensitivity of 50%–100% depending on the respiratory target, with an analytical specificity ≥ 99.0%. Most significant differences were found for the detection of adenovirus, human coronaviruses, respiratory syncytial virus, human rhinovirus/enterovirus and SARS‐CoV‐2 (kappa‐score: 0.67–0.91). Co‐detections of respiratory pathogens were identified in 47 cases by BioFire‐RP2.1 and 29 by QIAstat‐Dx‐RP2.0. Agreement rates between the two multiplex panel tests decreased from 91.8% for single pathogen detections to 65.0% and 42.9% for co‐detecting two and three pathogens, respectively. Pathogen loads were significantly lower in co‐detections compared to single pathogen detections (p < 0.01), potentially explaining the lower detection rates with the QIAstat‐Dx‐RP2.0 in cases of multiple pathogens. In conclusion, our prospective multicenter evaluation showed good diagnostic performance of the QIAstat‐Dx‐RP2.0 assay, but lower detection rates for some respiratory targets compared to BioFire‐RP2.1. As QIAstat‐Dx‐RP2.0 offers advantages in handling, noise emission, cost effectiveness, and provides semi‐quantitative results compared to BioFire‐RP2.1 an updated version with enhanced analytical sensitivity would be a viable alternative syndromic testing system for detecting respiratory pathogens.
- 23 December 2024
- Published by Wiley in Journal of Medical Virology
- Vol. 96 (12) , e70129
Open AccessMulticenter Evaluation of the QIAstat‐Dx and the BioFire Multiplex Panel Tests for the Detection of Respiratory Pathogens
Syndromic multiplex panel testing enables simultaneous detection of multiple respiratory pathogens, but limited data is available on the comparative diagnostic performance of different testing systems. In this multicenter prospective study, we aimed to compare the QIAstat‐Dx Respiratory Panel 2.0 (QIAstat‐Dx‐RP2.0) with the widely used BioFire‐RP2.1, using 269 respiratory clinical specimens. Concordant test results were obtained in 232 (86.3%) cases. Discordant test results included 33 BioFire‐RP2.1(+)/QIAstat‐Dx‐RP2.0(−) and 4 BioFire‐RP2.1(‐)/QIAstat‐Dx‐RP2.0(+) results. Discordant samples showed significantly lower pathogen loads than concordant ones (p < 0.01). Overall, the QIAstat‐Dx‐RP2.0 showed an analytical sensitivity of 50%–100% depending on the respiratory target, with an analytical specificity ≥ 99.0%. Most significant differences were found for the detection of adenovirus, human coronaviruses, respiratory syncytial virus, human rhinovirus/enterovirus and SARS‐CoV‐2 (kappa‐score: 0.67–0.91). Co‐detections of respiratory pathogens were identified in 47 cases by BioFire‐RP2.1 and 29 by QIAstat‐Dx‐RP2.0. Agreement rates between the two multiplex panel tests decreased from 91.8% for single pathogen detections to 65.0% and 42.9% for co‐detecting two and three pathogens, respectively. Pathogen loads were significantly lower in co‐detections compared to single pathogen detections (p < 0.01), potentially explaining the lower detection rates with the QIAstat‐Dx‐RP2.0 in cases of multiple pathogens. In conclusion, our prospective multicenter evaluation showed good diagnostic performance of the QIAstat‐Dx‐RP2.0 assay, but lower detection rates for some respiratory targets compared to BioFire‐RP2.1. As QIAstat‐Dx‐RP2.0 offers advantages in handling, noise emission, cost effectiveness, and provides semi‐quantitative results compared to BioFire‐RP2.1 an updated version with enhanced analytical sensitivity would be a viable alternative syndromic testing system for detecting respiratory pathogens.
- Open Access
- 22 February 2023
- Published by Wiley in Journal of Medical Virology
- Vol. 95 (2) , e28583
Impact of nucleic acid extraction procedures on human papillomavirus (HPV) detection and genotyping
Human papillomavirus (HPV) infections are often asymptomatic, but some of the >200 HPV genotypes confer a high risk for precancerous cervical lesions and cervical cancer. Current clinical management of HPV infections relies on reliable nucleic acid testing detection and genotyping. We prospectively compared nucleic acid extraction without and with prior centrifugation enrichment for detecting and genotyping HPV in cervical swabs with atypical squamous or glandular cells. Consecutive swabs were analyzed from 45 patients with atypical squamous or glandular cells. Nucleic acids were extracted in parallel using three procedures, Abbott‐M2000, Roche‐MagNA‐Pure‐96 Large‐Volume Kit without (Roche‐MP‐large) and with prior centrifugation (Roche‐MP‐large/spin) and tested using Seegene‐Anyplex‐II HPV28. In total, 54 HPV‐genotypes were detected in 45 samples, 51 by Roche‐MP‐large/spin, 48 by Abbott‐M2000 and 42 by Roche‐MP‐large. The overall concordance was 80% for detecting any HPV and 74% for specific HPV‐genotypes. Roche‐MP‐large/spin and Abbott‐M2000 showed the highest concordance for HPV detection (88.9%; kappa 0.78), and genotyping (88.5%). Two and more HPV‐genotypes were detected in 15 samples, often with one HPV being more abundant. Dilution series confirmed the specific detection of multiple HPV‐genotypes and their relative abundance. In 285 consecutive follow‐up samples extracted by Roche‐MP‐large/spin, the top three detected genotypes were the high‐risk HPV16, HPV53, HPV56 and the low‐risk HPV42, HPV54 and HPV61. Rate and breadth of HPV detection in cervical swabs depends on extraction protocols being highest after centrifugation/enrichment. As multivalent HPV‐vaccine coverage increases, detecting the evolving HPV virome depends on improved extraction and broader genotype coverage.
- 22 February 2023
- Published by Wiley in Journal of Medical Virology
- Vol. 95 (2) , e28583
Open AccessImpact of nucleic acid extraction procedures on human papillomavirus (HPV) detection and genotyping
Human papillomavirus (HPV) infections are often asymptomatic, but some of the >200 HPV genotypes confer a high risk for precancerous cervical lesions and cervical cancer. Current clinical management of HPV infections relies on reliable nucleic acid testing detection and genotyping. We prospectively compared nucleic acid extraction without and with prior centrifugation enrichment for detecting and genotyping HPV in cervical swabs with atypical squamous or glandular cells. Consecutive swabs were analyzed from 45 patients with atypical squamous or glandular cells. Nucleic acids were extracted in parallel using three procedures, Abbott‐M2000, Roche‐MagNA‐Pure‐96 Large‐Volume Kit without (Roche‐MP‐large) and with prior centrifugation (Roche‐MP‐large/spin) and tested using Seegene‐Anyplex‐II HPV28. In total, 54 HPV‐genotypes were detected in 45 samples, 51 by Roche‐MP‐large/spin, 48 by Abbott‐M2000 and 42 by Roche‐MP‐large. The overall concordance was 80% for detecting any HPV and 74% for specific HPV‐genotypes. Roche‐MP‐large/spin and Abbott‐M2000 showed the highest concordance for HPV detection (88.9%; kappa 0.78), and genotyping (88.5%). Two and more HPV‐genotypes were detected in 15 samples, often with one HPV being more abundant. Dilution series confirmed the specific detection of multiple HPV‐genotypes and their relative abundance. In 285 consecutive follow‐up samples extracted by Roche‐MP‐large/spin, the top three detected genotypes were the high‐risk HPV16, HPV53, HPV56 and the low‐risk HPV42, HPV54 and HPV61. Rate and breadth of HPV detection in cervical swabs depends on extraction protocols being highest after centrifugation/enrichment. As multivalent HPV‐vaccine coverage increases, detecting the evolving HPV virome depends on improved extraction and broader genotype coverage.
- Open Access
- 13 November 2018
- Published by Wiley in Journal of Medical Virology
- Vol. 91 (4) , 582-587
Comparing the Cobas Liat Influenza A/B and respiratory syncytial virus assay with multiplex nucleic acid testing
Influenza virus and respiratory syncytial virus (RSV) detection with short turn‐around‐time (TAT) is pivotal for rapid decisions regarding treatment and infection control. However, negative rapid testing results may come from poor assay sensitivity or from influenza‐like illnesses caused by other community‐acquired respiratory viruses (CARVs). We prospectively compared the performance of Cobas Liat Influenza A/B and RSV assay (LIAT) with our routine multiplexNAT‐1 (xTAG Respiratory Pathogen Panel; Luminex) and multiplexNAT‐2 (ePlex‐RPP; GenMark Diagnostics) using 194 consecutive nasopharyngeal swabs from patients with influenza‐like illness during winter 2017/2018. Discordant results were reanalyzed by specific in‐house quantitative nucleic acid amplification testing (NAT). LIAT was positive for influenza virus‐A, ‐B, and RSV in 18 (9.3%), 13 (6.7%), and 55 (28.4%) samples, and negative in 108 samples. Other CARVs were detected by multiplexNAT in 66 (34.0%) samples. Concordant results for influenza and RSV were seen in 190 (97.9%), discordant results in 4 (2.1%), which showed low‐level RSV (<40 000 copies/mL). Sensitivity and specificity of LIAT for influenza‐A, ‐B, and RSV were 100%, 100% and 100%, and 100%, 99.5% and 100%, respectively. The average TAT of LIAT was 20 minutes compared to 6 hours and 2 hours for the multiplexNAT‐1 and ‐2, respectively. Thus, LIAT demonstrated excellent sensitivity and specificity for influenza and RSV, which together with the simple sample processing and short TAT renders this assay suitable for near‐patient testing.
- 13 November 2018
- Published by Wiley in Journal of Medical Virology
- Vol. 91 (4) , 582-587
Open AccessComparing the Cobas Liat Influenza A/B and respiratory syncytial virus assay with multiplex nucleic acid testing
Influenza virus and respiratory syncytial virus (RSV) detection with short turn‐around‐time (TAT) is pivotal for rapid decisions regarding treatment and infection control. However, negative rapid testing results may come from poor assay sensitivity or from influenza‐like illnesses caused by other community‐acquired respiratory viruses (CARVs). We prospectively compared the performance of Cobas Liat Influenza A/B and RSV assay (LIAT) with our routine multiplexNAT‐1 (xTAG Respiratory Pathogen Panel; Luminex) and multiplexNAT‐2 (ePlex‐RPP; GenMark Diagnostics) using 194 consecutive nasopharyngeal swabs from patients with influenza‐like illness during winter 2017/2018. Discordant results were reanalyzed by specific in‐house quantitative nucleic acid amplification testing (NAT). LIAT was positive for influenza virus‐A, ‐B, and RSV in 18 (9.3%), 13 (6.7%), and 55 (28.4%) samples, and negative in 108 samples. Other CARVs were detected by multiplexNAT in 66 (34.0%) samples. Concordant results for influenza and RSV were seen in 190 (97.9%), discordant results in 4 (2.1%), which showed low‐level RSV (<40 000 copies/mL). Sensitivity and specificity of LIAT for influenza‐A, ‐B, and RSV were 100%, 100% and 100%, and 100%, 99.5% and 100%, respectively. The average TAT of LIAT was 20 minutes compared to 6 hours and 2 hours for the multiplexNAT‐1 and ‐2, respectively. Thus, LIAT demonstrated excellent sensitivity and specificity for influenza and RSV, which together with the simple sample processing and short TAT renders this assay suitable for near‐patient testing.
- 13 December 2017
- Published by Wiley in Journal of Medical Virology
- Vol. 90 (4) , 685-691
Enterovirus detection in patients with acute gastroenteritis in Switzerland
Acute gastroenteritis (GE) has a major impact on morbidity and mortality worldwide, yet comprehensive data regarding infectious agents including enteroviruses are scarce. We hypothesized that enteroviruses constitute a significant cause of acute GE. We analyzed 677 stool samples from 504 patients, which had been submitted for suspected infectious GE. 0.2 mL of stool suspension was extracted using the Abbott m2000sp robot and analysed by multiplex nucleic acid testing (NAT) using the Luminex xTAG gastrointestinal pathogen panel (GPP) as well as by specific NATs detecting enteroviruses and polioviruses. Median age of the patients was 6.6 years (IQR 1.1‐50.6; pediatric P = 0.0054). Only rotavirus (18.6%) and norovirus (12.1%) were more frequent. Clostridium difficile and Campylobacter jejuni were detected in 5.5% and 2.2% of stools, respectively. Adenovirus, E. coli O157, Salmonella, Shiga toxin‐producing E. coli (STEC), Shigella, Giardia lamblia, Cryptosporidium, and Entamoeba histolytica were rare (Vibrio cholerae, Yersinia enterocolitica, enterotoxigenic E. coli (ETEC) and poliovirus were not detected. Thus, non‐polio enteroviruses are the third most frequent pathogen in acute GE suggesting that enteroviruses may play an important role in GE even in developed, industrial health care settings.
- 13 December 2017
- Published by Wiley in Journal of Medical Virology
- Vol. 90 (4) , 685-691
Enterovirus detection in patients with acute gastroenteritis in Switzerland
Acute gastroenteritis (GE) has a major impact on morbidity and mortality worldwide, yet comprehensive data regarding infectious agents including enteroviruses are scarce. We hypothesized that enteroviruses constitute a significant cause of acute GE. We analyzed 677 stool samples from 504 patients, which had been submitted for suspected infectious GE. 0.2 mL of stool suspension was extracted using the Abbott m2000sp robot and analysed by multiplex nucleic acid testing (NAT) using the Luminex xTAG gastrointestinal pathogen panel (GPP) as well as by specific NATs detecting enteroviruses and polioviruses. Median age of the patients was 6.6 years (IQR 1.1‐50.6; pediatric P = 0.0054). Only rotavirus (18.6%) and norovirus (12.1%) were more frequent. Clostridium difficile and Campylobacter jejuni were detected in 5.5% and 2.2% of stools, respectively. Adenovirus, E. coli O157, Salmonella, Shiga toxin‐producing E. coli (STEC), Shigella, Giardia lamblia, Cryptosporidium, and Entamoeba histolytica were rare (Vibrio cholerae, Yersinia enterocolitica, enterotoxigenic E. coli (ETEC) and poliovirus were not detected. Thus, non‐polio enteroviruses are the third most frequent pathogen in acute GE suggesting that enteroviruses may play an important role in GE even in developed, industrial health care settings.
- Open Access
- 1 June 2006
- Published by Springer Nature in Journal of Translational Medicine
- Vol. 4 (1) , 47
Characterization of highly frequent epitope-specific CD45RA+/CCR7+/- T lymphocyte responses against p53-binding domains of the human polyomavirus BK large tumor antigen in HLA-A*0201+ BKV-seropositive donors
Human polyomavirus BK (BKV) has been implicated in oncogenic transformation. Its ability to replicate is determined by the binding of its large tumor antigen (LTag) to products of tumor-suppressor genes regulating cell cycle, as specifically p53. We investigated CD8+ T immune responses to BKV LTag portions involved in p53 binding in HLA-A*0201+ BKV LTag experienced individuals. Peptides selected from either p53-binding region (LTag351–450 and LTag533–626) by current algorithms and capacity to bind HLA-A*0201 molecule were used to stimulate CD8+ T responses, as assessed by IFN-γ gene expression ex vivo and detected by cytotoxicity assays following in vitro culture. We observed epitope-specific immune responses in all HLA-A*0201+ BKV LTag experienced individuals tested. At least one epitope, LTag579–587; LLLIWFRPV, was naturally processed in non professional antigen presenting cells and induced cytotoxic responses with CTL precursor frequencies in the order of 1/20'000. Antigen specific CD8+ T cells were only detectable in the CD45RA+ subset, in both CCR7+ and CCR7- subpopulations. These data indicate that widespread cellular immune responses against epitopes within BKV LTag-p53 binding regions exist and question their roles in immunosurveillance against tumors possibly associated with BKV infection.
- 1 June 2006
- Published by Springer Nature in Journal of Translational Medicine
- Vol. 4 (1) , 47
Open AccessCharacterization of highly frequent epitope-specific CD45RA+/CCR7+/- T lymphocyte responses against p53-binding domains of the human polyomavirus BK large tumor antigen in HLA-A*0201+ BKV-seropositive donors
Human polyomavirus BK (BKV) has been implicated in oncogenic transformation. Its ability to replicate is determined by the binding of its large tumor antigen (LTag) to products of tumor-suppressor genes regulating cell cycle, as specifically p53. We investigated CD8+ T immune responses to BKV LTag portions involved in p53 binding in HLA-A*0201+ BKV LTag experienced individuals. Peptides selected from either p53-binding region (LTag351–450 and LTag533–626) by current algorithms and capacity to bind HLA-A*0201 molecule were used to stimulate CD8+ T responses, as assessed by IFN-γ gene expression ex vivo and detected by cytotoxicity assays following in vitro culture. We observed epitope-specific immune responses in all HLA-A*0201+ BKV LTag experienced individuals tested. At least one epitope, LTag579–587; LLLIWFRPV, was naturally processed in non professional antigen presenting cells and induced cytotoxic responses with CTL precursor frequencies in the order of 1/20'000. Antigen specific CD8+ T cells were only detectable in the CD45RA+ subset, in both CCR7+ and CCR7- subpopulations. These data indicate that widespread cellular immune responses against epitopes within BKV LTag-p53 binding regions exist and question their roles in immunosurveillance against tumors possibly associated with BKV infection.
- Open Access
- 1 February 1996
- Published by Microbiology Society in Journal of General Virology
- Vol. 77 (2) , 247-255
Identification of hepatitis A virus non-structural protein 2B and its release by the major virus protease 3C
The RNA genome of hepatitis A virus (HAV) encodes a giant polyprotein that is putatively cleaved proteolytically into four structural and seven non-structural proteins. So far, most of the proposed non-structural proteins and their respective cleavage sites have not been identified. A vaccinia virus recombinant (vRGORF) containing the complete HAV ORF under the control of the bacteriophage T7 promoter was used to express HAV in recombinant animal cells (BT7-H) that constitutively expressed T7 DNA-dependent RNA polymerase. A HAV-specific 27.5 kDa expression product was identified as peptide 2B. The 27.5 kDa 2B antigen was also found in HAV-infected MRC-5 cells. The N-terminal amino acid residues of the new peptide 2B are Ala-Lys-Ile-Ser-Leu-Phe and polyprotein cleavage between 2A and 2B occurred at amino acids 836-837 (Gln-Ala). Furthermore, heterologous expression in the same system of regions P1-P2 and of the protease 3C (3Cpro) gene, showed that P1-P2 polyprotein is not cleaved autocatalytically but by 3Cpro. Hence, 3Cpro is effective in cleaving the polyprotein 2A-2B junction.
- 1 February 1996
- Published by Microbiology Society in Journal of General Virology
- Vol. 77 (2) , 247-255
Open AccessIdentification of hepatitis A virus non-structural protein 2B and its release by the major virus protease 3C
The RNA genome of hepatitis A virus (HAV) encodes a giant polyprotein that is putatively cleaved proteolytically into four structural and seven non-structural proteins. So far, most of the proposed non-structural proteins and their respective cleavage sites have not been identified. A vaccinia virus recombinant (vRGORF) containing the complete HAV ORF under the control of the bacteriophage T7 promoter was used to express HAV in recombinant animal cells (BT7-H) that constitutively expressed T7 DNA-dependent RNA polymerase. A HAV-specific 27.5 kDa expression product was identified as peptide 2B. The 27.5 kDa 2B antigen was also found in HAV-infected MRC-5 cells. The N-terminal amino acid residues of the new peptide 2B are Ala-Lys-Ile-Ser-Leu-Phe and polyprotein cleavage between 2A and 2B occurred at amino acids 836-837 (Gln-Ala). Furthermore, heterologous expression in the same system of regions P1-P2 and of the protease 3C (3Cpro) gene, showed that P1-P2 polyprotein is not cleaved autocatalytically but by 3Cpro. Hence, 3Cpro is effective in cleaving the polyprotein 2A-2B junction.