A Randomized Controlled Clinical Trial Comparing Ventricular Fibrillation Detection Time Between Two Transvenous Defibrillator Models
Authors:
- 1 July 1999
- journal article
- clinical trial
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 22 (7) , 990-998
Abstract
The Ventak AV is an implantable cardioverter defibrillator with dual chamber pacing capability. Features include detection and treatment of ventricular arrhythmias, detection of atrial arrhythmias, as well as dual chamber pacing. The objective of the investigation was to verify the efficacy of the Ventak AV in detecting ventricular fibrillation in the presence of dual chamber pacing. Thirty‐three patients, who were to receive an implantable defibrillator were randomized (1:1) in a paired comparison study to the Ventak AV (study device) and the Ventak Mini (control) during defibrillation threshold testing. In order to create a “worst case scenario” for sensing of ventricular fibrillation, pacing was performed at high lower rate limit values (Ventak AV DDD pacing at 150/min, Ventak Mini at VVI 100/min). Ventricular fibrillation was induced and the randomized device was allowed to detect and treat the arrhythmia. This test was repeated for each patient using the alternate device in a randomized order, such that all patients were tested with both devices. The mean ventricular fibrillation detection time for the Ventak AV was 2.0 ± 0.11 seconds and for the control device the detection time was 1.8 ± 0.11 seconds (P = 0.26). Appropriate tachyarrhythmia therapy decision was documented in all episodes for both devices. The study patient population demonstrated equivalent ventricular fibrillation detection time between the Ventak AV and the Ventak Mini. The Ventak AV demonstrated effectiveness in detecting ventricular fibrillation in the presence of high rate dual chamber pacing.Keywords
This publication has 14 references indexed in Scilit:
- The Value of DDD Pacing in Patients with an Implantable Cardioverter DefibrillatorPacing and Clinical Electrophysiology, 1997
- Results of atrioventricular synchronous pacing with optimized delay in patients with severe congestive heart failureThe American Journal of Cardiology, 1995
- Implantation of transvenous nonthoracotomy cardioverter-defibrillator systems in patients with permanent endocardial pacemakersAmerican Heart Journal, 1995
- Prospective randomised trial of atrial versus ventricular pacing in sick-sinus syndromeThe Lancet, 1994
- Results of permanent dual-chamber pacing in symptomatic nonobstructive hypertrophic cardiomyopathyThe American Journal of Cardiology, 1994
- Long-term efficacy of physiologic dual-chamber pacing in the treatment of end-stage idiopathic dilated cardiomyopathyThe American Journal of Cardiology, 1992
- Electrocardiographically Documented Unnecessary, Spontaneous Shocks in 241 Patients With Implantable Cardioverter DefibrillatorsPacing and Clinical Electrophysiology, 1992
- Effects of dual-chamber pacing with short atrioventricular delay in dilated cardiomyopathyThe Lancet, 1992
- Effects of dual-chamber pacing in hypertrophic obstructive cardiomyopathyThe Lancet, 1992
- Usefulness of physiologic dual-chamber pacing in drug-resistant idiopathic dilated cardiomyopathyThe American Journal of Cardiology, 1990