The role of 3-dimensional printed models in the management of the distal radius fractures
Open Access
- 1 January 2023
- journal article
- research article
- Published by AVES YAYINCILIK A.Ş. in Acta Orthopaedica et Traumatologica Turcica
- Vol. 57 (1) , 40-45
Abstract
Objective: This study aimed to compare inter- and intra-observer agreement between radiographs with 2-dimensional and 3-dimensional computed tomography scans with and without 3-dimensional printed models in the evaluation of the distal radius fracture of Association for Osteo synth esis/ Ortho paedi c Trauma Association type C classification. Methods: Fifteen consecutive cases with X-Rays, 2-dimensional and 3-dimensional computed tomography reconstructions views, and 3-dimensional printed models were selected. Three-dimensional printed models of the distal radius fractures were created using 2-dimensional computed tomography scan files in Digital Imaging and Communication in Medicine format, processed with the 3-dimensional Slicer software, and segmented, creating a 3-dimensional printed model in Standard Triangle Language format. Threedimensional models were printed using fused deposition modeling (FDM) type 3D printer Zortrax M200Plus using polylactic acid material on a scale of 1 : 1. Twenty observers were invited into the study. Results: Intra- and inter-observer reliability was analyzed using Fleiss’ kappa statistics. Overall kappa values for both groups in interobserver agreement range from 0.113 to 0.283 and in intra-observer agreement from 0.25 to 0.545. Generally, inter-observer agreement increased with additional 3-dimensional printed models from slight to fair, and intra-observer agreement increased from fair to moderate. Surgeons’ opinions about 3-dimensional printed models with Likert scale-type questions show positive overall results ranging from 8.3± 2.1 to 8.6 ± 1.4. Conclusion: This study has shown that the inter- and intra-observer agreement with the addition of a 3-dimensional printed model for the evaluation of the distal radius fractures of Association For Osteo synth esis/ Ortho pedic Trauma Association C type for classification, fractures morphology, and preoperative planning tends to increase; however, improvements for an inter-observer agreement remain fair. Level of Evidence: Level III Diagnostic Study Cite this article as: Grinčuk A, Makulavičius A, Porvaneckas N, Ryliškis S, Šatkauskas I, Uvarovas V. The role of 3-dimensional printed models in the management of the distal radius fractures. Acta Orthop Traumatol Turc., 2023;57(1):40-45.Keywords
This publication has 12 references indexed in Scilit:
- Classification systems for distal radius fracturesActa Orthopaedica, 2017
- Volar locking plate (VLP) versus non-locking plate (NLP) in the treatment of die-punch fractures of the distal radius, an observational studyInternational Journal of Surgery, 2016
- AO Distal Radius Fracture Classification: Global Perspective on Observer AgreementJournal of Wrist Surgery, 2016
- Classification and treatment of distal radius fractures: a survey among orthopaedic trauma surgeons and residentsEuropean Journal of Trauma and Emergency Surgery, 2016
- The relationship between radiographic parameters and clinical outcome of distal radius fractures in elderly patientsOrthopaedics & Traumatology: Surgery & Research, 2015
- Is it time to revisit the AO classification of fractures of the distal radius?The Bone & Joint Journal, 2015
- Fracture of the Distal Radius: Epidemiology and Premanagement Radiographic CharacterizationAmerican Journal of Roentgenology, 2014
- Incidence and characteristics of distal radial fractures in an urban population in The NetherlandsEuropean Journal of Trauma and Emergency Surgery, 2014
- The Influence of Three-Dimensional Computed Tomography Reconstructions on the Characterization and Treatment of Distal Radial FracturesJournal of Bone and Joint Surgery, 2006
- The Measurement of Observer Agreement for Categorical DataBiometrics, 1977