SRSigitas Ryliskis

Sigitas Ryliskis

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sigitas Ryliskis has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The role of 3-dimensional printed models in the management of the distal radius fractures

    by Aleksandr Grinčuk, Aleksas Makulavičius, Narūnas Porvaneckas, Sigitas Ryliškis, Igoris Šatkauskas, Valentinas Uvarovas

    Objective: This study aimed to compare inter- and intra-observer agreement between radiographs with 2-dimensional and 3-dimensional computed tomography scans with and without 3-dimensional printed models in the evaluation of the distal radius fracture of Association for Osteo synth esis/ Ortho paedi c Trauma Association type C classification. Methods: Fifteen consecutive cases with X-Rays, 2-dimensional and 3-dimensional computed tomography reconstructions views, and 3-dimensional printed models were selected. Three-dimensional printed models of the distal radius fractures were created using 2-dimensional computed tomography scan files in Digital Imaging and Communication in Medicine format, processed with the 3-dimensional Slicer software, and segmented, creating a 3-dimensional printed model in Standard Triangle Language format. Threedimensional models were printed using fused deposition modeling (FDM) type 3D printer Zortrax M200Plus using polylactic acid material on a scale of 1 : 1. Twenty observers were invited into the study. Results: Intra- and inter-observer reliability was analyzed using Fleiss’ kappa statistics. Overall kappa values for both groups in interobserver agreement range from 0.113 to 0.283 and in intra-observer agreement from 0.25 to 0.545. Generally, inter-observer agreement increased with additional 3-dimensional printed models from slight to fair, and intra-observer agreement increased from fair to moderate. Surgeons’ opinions about 3-dimensional printed models with Likert scale-type questions show positive overall results ranging from 8.3± 2.1 to 8.6 ± 1.4. Conclusion: This study has shown that the inter- and intra-observer agreement with the addition of a 3-dimensional printed model for the evaluation of the distal radius fractures of Association For Osteo synth esis/ Ortho pedic Trauma Association C type for classification, fractures morphology, and preoperative planning tends to increase; however, improvements for an inter-observer agreement remain fair. Level of Evidence: Level III Diagnostic Study Cite this article as: Grinčuk A, Makulavičius A, Porvaneckas N, Ryliškis S, Šatkauskas I, Uvarovas V. The role of 3-dimensional printed models in the management of the distal radius fractures. Acta Orthop Traumatol Turc., 2023;57(1):40-45.


  • Open Access

    Effect of Biological Environment on Polyester Surgical Suture's Physical Properties: An Experimental Study in Rats

    by Dominykas Stankevicius, Justinas Jonusas, Violeta Zalgeviciene, Sigitas Ryliskis

    The following study aims to analyze the alteration of nonabsorbable polyester surgical suture physical properties after in vivo incubation. A comparative study of braided nonabsorbable polyester 2/0 (U.S.P) sutures was performed. The control in vitro group and three experimental in vivo subgroups, composed of ten sutures in each, were created. All 30 experimental sutures were implanted into a total of 15 laboratory rats subcutaneous tissue (two sutures in each rat) and removed after seven, eight and nine weeks, respectively. Further, they were attached to the mechanical testing device and affected with a mechanical force, increasing the load by 0,1 N/s until complete breakage. Tensile strength (TS), failure displacement (FD), failure strain (FS) and failure stress (FST) were measured at the point of failure and compared to the same parameters of the control group. No statistically significant difference was found in the physical parameters of the samples between the experimental and control groups (TS [p = 0.358], FD [p = 0.258], FS [p = 0.258] FST [p = 0.358]). A statistically significant difference was found in the failure load between sutures that break on the knot site (KS) and the rest of the samples: significantly less force was needed to break the suture on the KS. Moreover, most of the breaks on the KS occurred in sutures that were incubated for the longest period of nine weeks (n = 4). An anomaly of partial failure (PF) was noticed. Sutures with PF elongated significantly more compared to the sutures that did not undergo PF in the control and in experimental groups (p = 0,044; p = 0,017; p = 0,016; p = 0,013). The biological environment had no radical aftereffects to the suture’s physical properties. In vivo exposure may cause the suture to break on the KS more frequently and may lead to PF, when a few sutures composed of fiber fail. Sutures that undergo PF tend to elongate further.