Comparison of clip and needle electrodes for multifrequency bioimpedance analysis in anesthetized dogs
Authors:
- Jun TamuraJTJun Tamura
- Takaharu ItamiTITakaharu Itami
- Keiko KatoKKKeiko Kato
- Chihiro SugitaCSChihiro Sugita
- Norihiko OyamaNONorihiko Oyama
- Kazuto YamashitaKYKazuto Yamashita
Open Access
- 6 August 2026
- journal article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (8) , e0355338
Abstract
Multifrequency bioimpedance analysis provides resistance, reactance, and phase angle measurements that are used to characterize body fluid distribution and cellular electrical properties. However, studies reporting on body composition assessment using multifrequency bioimpedance analysis in dogs remain limited. Therefore, we aimed to evaluate the measurement characteristics of trunk multifrequency bioimpedance analysis in dogs and assess the influence of body position and electrode type and placement. We anesthetized seven adult Beagle dogs and performed trunk multifrequency bioimpedance analysis at 5, 50, and 250 kHz using clip and needle electrodes in sternal and left lateral recumbency at three electrode paths. For each condition, 150 repeated measurements were obtained and summarized as a mean value. Repeatability and inter-individual variability were assessed using coefficients of variation. Agreement between electrode types was assessed using Bland–Altman analysis and correlation analysis, and the effects of electrode type and body position were evaluated using linear mixed-effects models with dogs as a random effect. Measurements were feasible under all conditions and showed low intra-individual variability. Inter-individual variability was generally 10–15%, but higher variability was observed for reactance and phase angle at low frequencies. Mean biases between clip and needle electrodes were small for most parameters; however, reactance and phase angle at 5 kHz showed weaker correlations and wider limits of agreement. Across models, between-dog differences accounted for most variability, whereas body position influenced several parameters when the stifle was included in the electrode path. These data indicate that clip electrodes yield measurements with small mean biases relative to those obtained using needle electrodes under controlled conditions in anesthetized dogs; however, the limits of agreement varied among parameters, and wider differences observed at low frequencies suggest that the two electrode types should not be considered fully interchangeable. Accordingly, electrode placement and body position should be standardized for experimental comparison and carefully controlled when monitoring longitudinal changes within individual dogs.Keywords
This publication has 21 references indexed in Scilit:
- Bioelectrical Impedance Analysis (BIA) detects body resistance increase in dogs undergoing blood donationVeterinary Research Communications, 2024
- Measuring body composition in dogs using bioelectrical impedance spectroscopyThe Veterinary Journal, 2024
- Bioimpedance Indices of Fluid Overload and Cardiorenal Outcomes in Heart Failure and Chronic Kidney Disease: a Systematic ReviewJournal of Cardiac Failure, 2022
- Is phase angle a valuable prognostic tool in cancer patients' survival? A systematic review and meta-analysis of available literatureClinical Nutrition, 2021
- Bioelectrical Impedance Analysis Measures and Clinical Outcomes in CKDAmerican Journal of Kidney Diseases, 2018
- Glucose-independent segmental phase angles from multi-frequency bioimpedance analysis to discriminate diabetes mellitusScientific Reports, 2018
- Measuring body composition in dogs using multifrequency bioelectrical impedance analysis and dual energy X-ray absorptiometryThe Veterinary Journal, 2016
- Bioelectrical phase angle and impedance vector analysis – Clinical relevance and applicability of impedance parametersClinical Nutrition, 2012
- Body fluid volumes measurements by impedance: A review of bioimpedance spectroscopy (BIS) and bioimpedance analysis (BIA) methodsMedical Engineering & Physics, 2008
- Noninvasive estimation of extravascular lung water using bioimpedanceJournal of Surgical Research, 1989