Jun Tamura
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jun Tamura has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
A. Umemura
1 shared publicationAkira Mitsuyoshi
1 shared publication- Akira Yoshikawa
Juntendo University
1 shared publication Chihiro Sugita
1 shared publication- Daisuke Iioka
Department of Electrical and Electronic Engineering, College of Engineering, Chubu University, Kasugai 487-8501, Japan
1 shared publication Fumihiko Inoue
Otsu Red Cross Hospital
1 shared publication
Latest Publications
- Open Access
- 6 August 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (8) , e0355338
Comparison of clip and needle electrodes for multifrequency bioimpedance analysis in anesthetized dogs
Multifrequency bioimpedance analysis provides resistance, reactance, and phase angle measurements that are used to characterize body fluid distribution and cellular electrical properties. However, studies reporting on body composition assessment using multifrequency bioimpedance analysis in dogs remain limited. Therefore, we aimed to evaluate the measurement characteristics of trunk multifrequency bioimpedance analysis in dogs and assess the influence of body position and electrode type and placement. We anesthetized seven adult Beagle dogs and performed trunk multifrequency bioimpedance analysis at 5, 50, and 250 kHz using clip and needle electrodes in sternal and left lateral recumbency at three electrode paths. For each condition, 150 repeated measurements were obtained and summarized as a mean value. Repeatability and inter-individual variability were assessed using coefficients of variation. Agreement between electrode types was assessed using Bland–Altman analysis and correlation analysis, and the effects of electrode type and body position were evaluated using linear mixed-effects models with dogs as a random effect. Measurements were feasible under all conditions and showed low intra-individual variability. Inter-individual variability was generally 10–15%, but higher variability was observed for reactance and phase angle at low frequencies. Mean biases between clip and needle electrodes were small for most parameters; however, reactance and phase angle at 5 kHz showed weaker correlations and wider limits of agreement. Across models, between-dog differences accounted for most variability, whereas body position influenced several parameters when the stifle was included in the electrode path. These data indicate that clip electrodes yield measurements with small mean biases relative to those obtained using needle electrodes under controlled conditions in anesthetized dogs; however, the limits of agreement varied among parameters, and wider differences observed at low frequencies suggest that the two electrode types should not be considered fully interchangeable. Accordingly, electrode placement and body position should be standardized for experimental comparison and carefully controlled when monitoring longitudinal changes within individual dogs.
- 6 August 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (8) , e0355338
Open AccessComparison of clip and needle electrodes for multifrequency bioimpedance analysis in anesthetized dogs
Multifrequency bioimpedance analysis provides resistance, reactance, and phase angle measurements that are used to characterize body fluid distribution and cellular electrical properties. However, studies reporting on body composition assessment using multifrequency bioimpedance analysis in dogs remain limited. Therefore, we aimed to evaluate the measurement characteristics of trunk multifrequency bioimpedance analysis in dogs and assess the influence of body position and electrode type and placement. We anesthetized seven adult Beagle dogs and performed trunk multifrequency bioimpedance analysis at 5, 50, and 250 kHz using clip and needle electrodes in sternal and left lateral recumbency at three electrode paths. For each condition, 150 repeated measurements were obtained and summarized as a mean value. Repeatability and inter-individual variability were assessed using coefficients of variation. Agreement between electrode types was assessed using Bland–Altman analysis and correlation analysis, and the effects of electrode type and body position were evaluated using linear mixed-effects models with dogs as a random effect. Measurements were feasible under all conditions and showed low intra-individual variability. Inter-individual variability was generally 10–15%, but higher variability was observed for reactance and phase angle at low frequencies. Mean biases between clip and needle electrodes were small for most parameters; however, reactance and phase angle at 5 kHz showed weaker correlations and wider limits of agreement. Across models, between-dog differences accounted for most variability, whereas body position influenced several parameters when the stifle was included in the electrode path. These data indicate that clip electrodes yield measurements with small mean biases relative to those obtained using needle electrodes under controlled conditions in anesthetized dogs; however, the limits of agreement varied among parameters, and wider differences observed at low frequencies suggest that the two electrode types should not be considered fully interchangeable. Accordingly, electrode placement and body position should be standardized for experimental comparison and carefully controlled when monitoring longitudinal changes within individual dogs.
- 1 January 2023
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Dynamics & Design Conference
- Vol. 2023, A11
深度センシングの空間平滑化による路面変位推定を用いた前後輪プレビューサスペンション制御
Various active suspension control systems have been studied to improve the ride comfort of automobiles. In fact, there are vehicles in the real world in which active suspension has been used to reduce vehicle vibration. However, while the rear wheels can be controlled based on sensors-information from the front wheels, the front wheels cannot avoid the effects of uneven surfaces. Therefore, this study proposes a preview suspension control system that is suitable for uneven surfaces by using Optimal Preview Control (OPC) to reduce the effect of unevenness from the front wheels by detecting unevenness of the road surface in advance using a stereo camera to create a three-dimensional point cloud of the front including the road surface.
- 1 January 2023
- Published by Japan Society of Mechanical Engineers in The Proceedings of the Dynamics & Design Conference
- Vol. 2023, A11
深度センシングの空間平滑化による路面変位推定を用いた前後輪プレビューサスペンション制御
Various active suspension control systems have been studied to improve the ride comfort of automobiles. In fact, there are vehicles in the real world in which active suspension has been used to reduce vehicle vibration. However, while the rear wheels can be controlled based on sensors-information from the front wheels, the front wheels cannot avoid the effects of uneven surfaces. Therefore, this study proposes a preview suspension control system that is suitable for uneven surfaces by using Optimal Preview Control (OPC) to reduce the effect of unevenness from the front wheels by detecting unevenness of the road surface in advance using a stereo camera to create a three-dimensional point cloud of the front including the road surface.
- Open Access
- 9 May 2022
- Published by XMLink in Journal of Veterinary Science
- Vol. 23 (4) , e53
Sparing effect of tramadol, lidocaine, dexmedetomidine and their combination on the minimum alveolar concentration of sevoflurane in dogs
El-Hawari SF, et al. J Vet Sci. 2022 May;23:e53. https://doi.org/10.4142/jvs.21305
- 9 May 2022
- Published by XMLink in Journal of Veterinary Science
- Vol. 23 (4) , e53
Open AccessSparing effect of tramadol, lidocaine, dexmedetomidine and their combination on the minimum alveolar concentration of sevoflurane in dogs
El-Hawari SF, et al. J Vet Sci. 2022 May;23:e53. https://doi.org/10.4142/jvs.21305
- Open Access
- 1 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Hosting capacity analysis of many distributed photovoltaic systems in future distribution networks
Installation of photovoltaic (PV) systems need to be accelerated much for the mitigation of climate change. This paper targets on huge penetration of distributed PV systems into feeders, of which the total PV capacity is several or several ten times of the existing load. Three kinds of countermeasures, improvement of conductor sizes, partial boosting voltage, smart invertors, and their combinations were analyzed with the criteria of the PV hosting capacity. Simulation results suggested that, without PV reactive power control, the increase of the hosting capacity for improvement of conductor size and boosting voltage were limited because of voltage rise in low voltage networks. The combination of the three kinds of countermeasures were necessary for the huge penetration of distributed PV systems. In such cases, the voltage needed to drop in the middle voltage networks in order to compensate the voltage rise in low voltage networks.
- 1 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Open AccessHosting capacity analysis of many distributed photovoltaic systems in future distribution networks
Installation of photovoltaic (PV) systems need to be accelerated much for the mitigation of climate change. This paper targets on huge penetration of distributed PV systems into feeders, of which the total PV capacity is several or several ten times of the existing load. Three kinds of countermeasures, improvement of conductor sizes, partial boosting voltage, smart invertors, and their combinations were analyzed with the criteria of the PV hosting capacity. Simulation results suggested that, without PV reactive power control, the increase of the hosting capacity for improvement of conductor size and boosting voltage were limited because of voltage rise in low voltage networks. The combination of the three kinds of countermeasures were necessary for the huge penetration of distributed PV systems. In such cases, the voltage needed to drop in the middle voltage networks in order to compensate the voltage rise in low voltage networks.
- Open Access
- 1 January 2011
- Published by The Japanese Journal of Gastroenterological Surgery in The Japanese Journal of Gastroenterological Surgery
- Vol. 44 (12) , 1565-1572
A Case of von Hippel-Lindau Disease Diagnosed by the Combination of Pheochromocytoma and Pancreatic Endocrine Tumor
- 1 January 2011
- Published by The Japanese Journal of Gastroenterological Surgery in The Japanese Journal of Gastroenterological Surgery
- Vol. 44 (12) , 1565-1572
Open AccessA Case of von Hippel-Lindau Disease Diagnosed by the Combination of Pheochromocytoma and Pancreatic Endocrine Tumor
- 16 October 2006
- Published by Springer Nature in Journal of Gastroenterology
- Vol. 41 (9) , 913-918
A case of ectopic hepatocellular carcinoma in the jejunum
We describe the case of a 72 year-old man with a huge tumor in his lower abdomen and extremely high serum α-fetoprotein levels (99 100 ng/ml). The patient had no risk factors for hepatocellular carcinoma (HCC) or liver disease. Computed tomography, magnetic resonance imaging, and hepatic angiography detected no tumors in the liver before surgery. The arteries feeding the tumor arose from the superior mesenteric artery, but were not recognized on celiac angiography. Histologically, the tumor cells had features of HCC. Immunohistochemical staining revealed that the tumor cells were positive for AFP and the hepatocyte paraffin 1 monoclonal antibody. Furthermore, the tumor cells were strongly positive for cytokeratin 8 and cytokeratin 18, which are usually expressed on hepatocytes in HCC, and negative for both cytokeratin 7 and cytokeratin 20, which are not usually expressed in HCC. Hence, the tumor was diagnosed as an ectopic HCC that possibly developed from ectopic liver tissue in the jejunum. Approximately 2 months after the operation, transarterial chemoembolization was performed for liver metastasis from this tumor. One year after the transarterial chemoembolization procedure, the patient remains well with no evidence of a recurrent tumor or serum AFP elevation.
- 16 October 2006
- Published by Springer Nature in Journal of Gastroenterology
- Vol. 41 (9) , 913-918
A case of ectopic hepatocellular carcinoma in the jejunum
We describe the case of a 72 year-old man with a huge tumor in his lower abdomen and extremely high serum α-fetoprotein levels (99 100 ng/ml). The patient had no risk factors for hepatocellular carcinoma (HCC) or liver disease. Computed tomography, magnetic resonance imaging, and hepatic angiography detected no tumors in the liver before surgery. The arteries feeding the tumor arose from the superior mesenteric artery, but were not recognized on celiac angiography. Histologically, the tumor cells had features of HCC. Immunohistochemical staining revealed that the tumor cells were positive for AFP and the hepatocyte paraffin 1 monoclonal antibody. Furthermore, the tumor cells were strongly positive for cytokeratin 8 and cytokeratin 18, which are usually expressed on hepatocytes in HCC, and negative for both cytokeratin 7 and cytokeratin 20, which are not usually expressed in HCC. Hence, the tumor was diagnosed as an ectopic HCC that possibly developed from ectopic liver tissue in the jejunum. Approximately 2 months after the operation, transarterial chemoembolization was performed for liver metastasis from this tumor. One year after the transarterial chemoembolization procedure, the patient remains well with no evidence of a recurrent tumor or serum AFP elevation.