Detection of Monitoring Materials on Bedside Chest Radiographs with the Most Recent Generation of Storage Phosphor Plates: Dose Increase Does Not Improve Detection Performance
Authors:
- Edith EisenhuberEEEdith Eisenhuber
- Alfred StadlerASAlfred Stadler
- Mathias ProkopMPMathias Prokop
- Michael FuchsjägerMFMichael Fuchsjäger
- Michael WeberMWMichael Weber
- Cornelia Schaefer-ProkopCSCornelia Schaefer-Prokop
- 1 April 2003
- journal article
- clinical trial
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 227 (1) , 216-221
Abstract
To evaluate the performance of the most recent generation of storage phosphor plates for the detection of low-contrast catheter material on bedside chest radiographs.In 10 patients in the intensive care unit, bedside chest radiographs were obtained with a 400-speed conventional screen-film system and with storage phosphor plates with exposure levels comparable to a 200-, 400-, or 800-speed conventional system. The chest radiograph was divided into 20 regions, 60% of which were superimposed with low-contrast catheter fragments. Six observers independently assessed the presence of catheter fragments by using a receiver operating characteristic (ROC) methodology.Detection performance (mean area under the ROC curve [Az]) with the storage phosphor plates was significantly superior to that with the screen-film system (Az = 0.76) at all three dose levels (Az = 0.88, 0.87, and 0.83 for 200-, 400-, and 800-speed doses, respectively; P <.05). Increasing the dose to a 200-speed system did not significantly increase detection performance compared with that with the 400-speed digital radiographs (Az = 0.88 vs 0.87). Dose reduction to 800 speed significantly deteriorated the detection performance (Az = 0.83) compared with that with the 400- and 200-speed digital radiographs, respectively.The most recent generation of storage phosphor plates is superior to a 400-speed screen-film system for the detection of catheter material, even at an exposure level of 800 speed.Keywords
This publication has 11 references indexed in Scilit:
- Image quality for five modern chest radiography techniques: a modified FROC study with an anthropomorphic chest phantomEuropean Radiology, 1999
- Detection of Simulated Interstitial Lung Disease and Catheters with Selenium, Storage Phosphor, and Film-based RadiographyRadiology, 1999
- Chest radiography in the ICUClinical Imaging, 1997
- DQE(f) of four generations of computed radiography acquisition devicesMedical Physics, 1995
- Bedside chest radiography.Radiology, 1994
- Portable chest imaging: comparison of storage phosphor digital, asymmetric screen-film, and conventional screen-film systems.Radiology, 1993
- Threshold perception performance with computed and screen-film radiography: implications for chest radiography.Radiology, 1992
- Erkennbarkeit zentralvenöser Katheter bei Einsatz der digitalen Lumineszenzradiographie in der intensivmedizinischen RadiologieRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 1992
- Efficacy of daily routine chest radiographs in intubated, mechanically ventilated patientsCritical Care Medicine, 1991
- Improved control of image optical density with low-dose digital and conventional radiography in bedside imaging.Radiology, 1989