EEEdith Eisenhuber

Edith Eisenhuber

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Edith Eisenhuber has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Radiologische Diagnostik der Lungentuberkulose

    by E. Eisenhuber, G. Mostbeck, A. Bankier, A. Stadler, R. Rumetshofer

    Zusammenfassung Das Kennen und Erkennen charakteristischer Tuberkulose-assoziierter Lungenveränderungen stellt einen Grundpfeiler in der Diagnostik der Tuberkulose dar. Neben dem Thoraxröntgen spielt die Computertomographie bei der Lungentuberkulose eine zunehmend wichtigere Rolle, da sie wesentlich sensitiver beim Nachweis von Kavernen, einer hilären und mediastinalen Lymphadenopathie, von Streuherden und Komplikationen der Tuberkulose ist. Die Computertomographie erlaubt die Beurteilung einer Aktivität speziell bei negativem Nachweis der Mykobakterien im Sputum und bei multiresistenter Tuberkulose. Die Tuberkulose kann in Abhängigkeit von der Immunlage des Patienten ein sehr unterschiedliches Erscheinungsbild haben. Die frühzeitige Diagnose und Therapie sind entscheidend, um eine weitere Ausbreitung zu verhindern.


  • Detection of Monitoring Materials on Bedside Chest Radiographs with the Most Recent Generation of Storage Phosphor Plates: Dose Increase Does Not Improve Detection Performance

    by Edith Eisenhuber, Alfred Stadler, Mathias Prokop, Michael Fuchsjäger, Michael Weber, Cornelia Schaefer-Prokop

    To evaluate the performance of the most recent generation of storage phosphor plates for the detection of low-contrast catheter material on bedside chest radiographs.In 10 patients in the intensive care unit, bedside chest radiographs were obtained with a 400-speed conventional screen-film system and with storage phosphor plates with exposure levels comparable to a 200-, 400-, or 800-speed conventional system. The chest radiograph was divided into 20 regions, 60% of which were superimposed with low-contrast catheter fragments. Six observers independently assessed the presence of catheter fragments by using a receiver operating characteristic (ROC) methodology.Detection performance (mean area under the ROC curve [Az]) with the storage phosphor plates was significantly superior to that with the screen-film system (Az = 0.76) at all three dose levels (Az = 0.88, 0.87, and 0.83 for 200-, 400-, and 800-speed doses, respectively; P <.05). Increasing the dose to a 200-speed system did not significantly increase detection performance compared with that with the 400-speed digital radiographs (Az = 0.88 vs 0.87). Dose reduction to 800 speed significantly deteriorated the detection performance (Az = 0.83) compared with that with the 400- and 200-speed digital radiographs, respectively.The most recent generation of storage phosphor plates is superior to a 400-speed screen-film system for the detection of catheter material, even at an exposure level of 800 speed.


  • Primary pancreatic lymphoma presenting as acute pancreatitis in a child

    by Edith Eisenhuber, Rainer Schoefl, Peter Wiesbauer, Alexander A. Bankier