Patterned thin metal film for the lateral resolution measurement of photoacoustic tomography
Open Access
- 1 January 2012
- journal article
- research article
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 11 (1) , 37
Abstract
Image quality assessment method of photoacoustic tomography has not been completely standardized yet. Due to the combined nature of photonic signal generation and ultrasonic signal transmission in biological tissue, neither optical nor ultrasonic traditional methods can be used without modification. An optical resolution measurement technique was investigated for its feasibility for resolution measurement of photoacoustic tomography. A patterned thin metal film deposited on silica glass provides high contrast in optical imaging due to high reflectivity from the metal film and high transmission from the glass. It provides high contrast when it is used for photoacoustic tomography because thin metal film can absorb pulsed laser energy. An US Air Force 1951 resolution target was used to generate patterned photoacoustic signal to measure the lateral resolution. Transducer with 2.25 MHz bandwidth and a sample submerged in water and gelatinous block were tested for lateral resolution measurement. Photoacoustic signal generated from a thin metal film deposited on a glass can propagate along the surface or through the surrounding medium. First, a series of experiments with tilted sample confirmed that the measured photoacoustic signal is what is propagating through the medium. Lateral resolution of the photoacoustic tomography system was successfully measured for water and gelatinous block as media: 0.33 mm and 0.35 mm in water and gelatinous material, respectively, when 2.25 MHz transducer was used. Chicken embryo was tested for biomedical applications. A patterned thin metal film sample was tested for its feasibility of measuring lateral resolution of a photoacoustic tomography system. Lateral resolutions in water and gelatinous material were successfully measured using the proposed method. Measured resolutions agreed well with theoretical values.Keywords
This publication has 18 references indexed in Scilit:
- Tissue-mimicking phantoms for photoacoustic and ultrasonic imagingBiomedical Optics Express, 2011
- Integrated diffuse optical tomography and photoacoustic tomography: phantom validationsBiomedical Optics Express, 2011
- Laser induced plane acoustic wave generation, propagation, and interaction with rigid structures in waterJournal of Applied Physics, 2008
- Laser induced short plane acoustic wave focusing in waterApplied Physics Letters, 2007
- Boundary conditions in photoacoustic tomography and image reconstructionJournal of Biomedical Optics, 2007
- Photoacoustic imaging in biomedicineReview of Scientific Instruments, 2006
- Photoacoustic tomography of biological tissues with high cross‐section resolution: Reconstruction and experimentMedical Physics, 2002
- Schlieren imaging of laser-generated ultrasoundApplied Physics Letters, 2001
- Laser-generated ultrasound: its properties, mechanisms and multifarious applicationsJournal of Physics D: Applied Physics, 1993
- Speed of Sound in Pure WaterThe Journal of the Acoustical Society of America, 1972