CSChul-Gyu Song

Chul-Gyu Song

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Chul-Gyu Song has a total of 23 co-authors. Here are the top co-authors by number of shared publications:

  • Keo Sik Kim

    School of Electronics and Information Engineering, Chonbuk National University, 664-14, 1Ga, Deokjin-dong, Jeonju, Jeonbuk 561-756, Republic of Korea

    3 shared publications
  • Do-Hyun Kim

    Center for Devices and Radiological Health, U.S. Food and Drug Administration, 10903 New Hampshire Ave., Silver Spring, Maryland 20993, USA

    2 shared publications
  • Jae-Ho Han

    Johns Hopkins Univ. (United States)

    2 shared publications
  • Jeong Hwan Seo

    Chonbuk Natl Univ Hosp, Dept Rehabil Med, Sch Med, Jeonju 561712, Jeonbuk, South Korea

    2 shared publications
  • Jin U. Kang

    John Hopkins University

    2 shared publications
  • Dong-Ho Shin

    Department of Electronic Engineering, Chonbuk National University, Jeonju-si, Jeonbuk, Korea

    1 shared publication

Latest Publications

  • Targeting Oxidative Stress Using Nanoparticles as a Theranostic Strategy for Cardiovascular Diseases

    by Kye S. Kim, Chul Gyu Song, Peter M. Kang

    Significance: Nanomedicine is an application of nanotechnology that provides solutions to unmet medical challenges. The unique features of nanoparticles, such as their small size, modifiable components, and diverse functionality, make them attractive and suitable materials for novel diagnostic, therapeutic, or theranostic applications. Cardiovascular diseases (CVDs) are the major cause of noncommunicable illness in both developing and developed countries. Nanomedicine offers novel theranostic options for the treatment of CVDs. Recent Advances: Many innovative nanoparticles to target reactive oxygen species (ROS) have been developed. In this article, we review the characteristics of nanoparticles that are responsive to ROS, their limitations, and their potential clinical uses. Significant advances made in diagnosis of atherosclerosis and treatment of acute coronary syndrome using nanoparticles are discussed. Critical Issues: Although there is a tremendous potential for the nanoparticle applications in medicine, their safety should be considered while using in humans. We discuss the challenges that may be encountered with some of the innovative nanoparticles used in CVDs. Future Directions: The unique properties of nanoparticles offer novel diagnostic tool and potential therapeutic strategies. However, nanomedicine is still in its infancy, and further in-depth studies are needed before wide clinical application is achieved.


  • Open Access

    Removal of baseline wandering in ECG signal by improved detrending method

    by Seung-Won Shin, Kyeong-Seop Kim, Chul-Gyu Song, Jeong-Whan Lee, Jeong-Hwan Kim, Gyeo-Wun Jeung

    The very first step to process electrocardiogram (ECG) signal is to eliminate baseline wandering interference that is usually caused by electrode-skin impedance mismatch, motion artifacts due to a patient’s body moment or respiratory breathing. A new method is thus suggested to remove baseline wandering in ECG by improving the detrending method that was originally proposed for eliminating slow non-stationary trends from heart rate variability (HRV). In our proposed method, a global trend is estimated in terms of baseline wandering by merging the local trend based on an ECG segment that represents a part of the ECG signal. The experimental results show that the improved detrending method can efficiently resolve baseline wandering without distorting any morphological characteristic embedded in the ECG signal in no time delay manner.


  • Open Access

    Enhancement of objects in photoacoustic tomography using selective filtering

    by Dong-Ho Shin, Yoonseok Yang, Chul-Gyu Song

    Here we developed a real-time photoacoustic tomography (PAT) imaging acquisition device based on the linear array transducer utilized on ultrasonic devices. Also, we produced a phantom including diverse contrast media and acquired PAT imaging as the light source wavelength was changing to see if the contrast media reacted. Indocyanine green showed the highest reaction around the 800-nm band, methylene blue demonstrated the same in the 750-nm band, and gold nanoparticle showed the same in the 700-nm band. However, in the case of superparamagnetic iron oxide, we observed not reaction within the wavelength bands used herein to obtain imaging. Moreover, we applied selective filtering to the acquired PAT imaging to remove noise from around and reinforce the object’s area. Consequentially, we could see the object area in the imaging was effectively detected and the image noise was removed.

  • Open Access

    Patterned thin metal film for the lateral resolution measurement of photoacoustic tomography

    by Do-Hyun Kim, Dong-Ho Shin, Sang Hun Ryu, Chul-Gyu Song

    Image quality assessment method of photoacoustic tomography has not been completely standardized yet. Due to the combined nature of photonic signal generation and ultrasonic signal transmission in biological tissue, neither optical nor ultrasonic traditional methods can be used without modification. An optical resolution measurement technique was investigated for its feasibility for resolution measurement of photoacoustic tomography. A patterned thin metal film deposited on silica glass provides high contrast in optical imaging due to high reflectivity from the metal film and high transmission from the glass. It provides high contrast when it is used for photoacoustic tomography because thin metal film can absorb pulsed laser energy. An US Air Force 1951 resolution target was used to generate patterned photoacoustic signal to measure the lateral resolution. Transducer with 2.25 MHz bandwidth and a sample submerged in water and gelatinous block were tested for lateral resolution measurement. Photoacoustic signal generated from a thin metal film deposited on a glass can propagate along the surface or through the surrounding medium. First, a series of experiments with tilted sample confirmed that the measured photoacoustic signal is what is propagating through the medium. Lateral resolution of the photoacoustic tomography system was successfully measured for water and gelatinous block as media: 0.33 mm and 0.35 mm in water and gelatinous material, respectively, when 2.25 MHz transducer was used. Chicken embryo was tested for biomedical applications. A patterned thin metal film sample was tested for its feasibility of measuring lateral resolution of a photoacoustic tomography system. Lateral resolutions in water and gelatinous material were successfully measured using the proposed method. Measured resolutions agreed well with theoretical values.


  • Open Access

    Non-invasive algorithm for bowel motility estimation using a back-propagation neural network model of bowel sounds

    by Keo-Sik Kim, Jeong-Hwan Seo, Chul-Gyu Song

    Background: Radiological scoring methods such as colon transit time (CTT) have been widely used for the assessment of bowel motility. However, these radiograph-based methods need cumbersome radiological instruments and their frequent exposure to radiation. Therefore, a non-invasive estimation algorithm of bowel motility, based on a back-propagation neural network (BPNN) model of bowel sounds (BS) obtained by an auscultation, was devised. Methods: Twelve healthy males (age: 24.8 ± 2.7 years) and 6 patients with spinal cord injury (6 males, age: 55.3 ± 7.1 years) were examined. BS signals generated during the digestive process were recorded from 3 colonic segments (ascending, descending and sigmoid colon), and then, the acoustical features (jitter and shimmer) of the individual BS segment were obtained. Only 6 features (J 1, 3 , J 3, 3 , S 1, 2 , S 2, 1 , S 2, 2 , S 3, 2 ), which are highly correlated to the CTTs measured by the conventional method, were used as the features of the input vector for the BPNN. Results: As a results, both the jitters and shimmers of the normal subjects were relatively higher than those of the patients, whereas the CTTs of the normal subjects were relatively lower than those of the patients (p < 0.01). Also, through k-fold cross validation, the correlation coefficient and mean average error between the CTTs measured by a conventional radiograph and the values estimated by our algorithm were 0.89 and 10.6 hours, respectively. Conclusions: The jitter and shimmer of the BS signals generated during the peristalsis could be clinically useful for the discriminative parameters of bowel motility. Also, the devised algorithm showed good potential for the continuous monitoring and estimation of bowel motility, instead of conventional radiography, and thus, it could be used as a complementary tool for the non-invasive measurement of bowel motility.


  • An Acoustical Evaluation of Knee Sound for Non-invasive Screening and Early Detection of Articular Pathology

    by Keo Sik Kim, Jeong Hwan Seo, Chul Gyu Song

    Knee sound signals generated by knee movement are sometimes associated with degeneration of the knee joint surface and such sounds may be a useful index for early disease. In this study, we detected the acoustical parameters, such as the fundamental frequency (F0), mean amplitude of the pitches, and jitter and shimmer of knee sounds, and compared them according to the pathological conditions. Six normal subjects (4 males and 2 females, age: 28.3 ± 2.3 years) and 11 patients with knee problems were enrolled. The patients were divided into the 1st patient group (5 males and 1 female, age: 30.2 ± 10.3 years) with ruptured wounds of the meniscus and 2nd patient group (2 males and 3 females, age: 42.1 ± 16.2 years) with osteoarthritis. The mean values of F0, jitter and shimmer of the 2nd patient group were larger than those of the normal group, whereas those of the 1st patient group were smaller (p < 0.05). Also, the F0 and jitter in the standing position were larger than those in the sitting position in both the 1st and 2nd patient groups (p < 0.05). These results showed good potential for the non-invasive diagnosis and early detection of articular pathologies via an auscultation.


  • A study on the qualitative morphological features of the muscle and subcutaneous shapes in vivo using Fourier-domain common path OCT

    by Jae-Ho Han, Liu Xuan, Jin U. Kang, Chul-Gyu Song

    In this paper, we have demonstrated a polarization sensitive subcutaneous and muscle imaging based on common path optical coherence tomography (CP-OCT) using near infrared source. The axial and lateral resolutions of our PS-OCT system are 9μm and 6μm, respectively. The internal structural information has been extracted by the real-time signal analysis (Fourier Transform) from the modulated spectral intensity depending on the beam and tissue birefringence. Preliminary results using fresh beef and in vivo rat show that we can visualize the birefringence effect of the tissue collagen fibers in the samples for better image contrast and sensitivity for detection of hidden dermal structures. Compared to conventional CP-OCT, our proposed PS-OCT could provide depth-resolved images, which reflect tissue birefringence.