Chul-Gyu Song
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Chul-Gyu Song has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
Keo Sik Kim
School of Electronics and Information Engineering, Chonbuk National University, 664-14, 1Ga, Deokjin-dong, Jeonju, Jeonbuk 561-756, Republic of Korea
3 shared publications- Do-Hyun Kim
Center for Devices and Radiological Health, U.S. Food and Drug Administration, 10903 New Hampshire Ave., Silver Spring, Maryland 20993, USA
2 shared publications Jae-Ho Han
Johns Hopkins Univ. (United States)
2 shared publicationsJeong Hwan Seo
Chonbuk Natl Univ Hosp, Dept Rehabil Med, Sch Med, Jeonju 561712, Jeonbuk, South Korea
2 shared publicationsJin U. Kang
John Hopkins University
2 shared publicationsDong-Ho Shin
Department of Electronic Engineering, Chonbuk National University, Jeonju-si, Jeonbuk, Korea
1 shared publication
Latest Publications
- 8 January 2019
- Published by SAGE Publications in Antioxidants & Redox Signaling
- Vol. 30 (5) , 733-746
Targeting Oxidative Stress Using Nanoparticles as a Theranostic Strategy for Cardiovascular Diseases
Significance: Nanomedicine is an application of nanotechnology that provides solutions to unmet medical challenges. The unique features of nanoparticles, such as their small size, modifiable components, and diverse functionality, make them attractive and suitable materials for novel diagnostic, therapeutic, or theranostic applications. Cardiovascular diseases (CVDs) are the major cause of noncommunicable illness in both developing and developed countries. Nanomedicine offers novel theranostic options for the treatment of CVDs. Recent Advances: Many innovative nanoparticles to target reactive oxygen species (ROS) have been developed. In this article, we review the characteristics of nanoparticles that are responsive to ROS, their limitations, and their potential clinical uses. Significant advances made in diagnosis of atherosclerosis and treatment of acute coronary syndrome using nanoparticles are discussed. Critical Issues: Although there is a tremendous potential for the nanoparticle applications in medicine, their safety should be considered while using in humans. We discuss the challenges that may be encountered with some of the innovative nanoparticles used in CVDs. Future Directions: The unique properties of nanoparticles offer novel diagnostic tool and potential therapeutic strategies. However, nanomedicine is still in its infancy, and further in-depth studies are needed before wide clinical application is achieved.
- 8 January 2019
- Published by SAGE Publications in Antioxidants & Redox Signaling
- Vol. 30 (5) , 733-746
Targeting Oxidative Stress Using Nanoparticles as a Theranostic Strategy for Cardiovascular Diseases
Significance: Nanomedicine is an application of nanotechnology that provides solutions to unmet medical challenges. The unique features of nanoparticles, such as their small size, modifiable components, and diverse functionality, make them attractive and suitable materials for novel diagnostic, therapeutic, or theranostic applications. Cardiovascular diseases (CVDs) are the major cause of noncommunicable illness in both developing and developed countries. Nanomedicine offers novel theranostic options for the treatment of CVDs. Recent Advances: Many innovative nanoparticles to target reactive oxygen species (ROS) have been developed. In this article, we review the characteristics of nanoparticles that are responsive to ROS, their limitations, and their potential clinical uses. Significant advances made in diagnosis of atherosclerosis and treatment of acute coronary syndrome using nanoparticles are discussed. Critical Issues: Although there is a tremendous potential for the nanoparticle applications in medicine, their safety should be considered while using in humans. We discuss the challenges that may be encountered with some of the innovative nanoparticles used in CVDs. Future Directions: The unique properties of nanoparticles offer novel diagnostic tool and potential therapeutic strategies. However, nanomedicine is still in its infancy, and further in-depth studies are needed before wide clinical application is achieved.
- Open Access
- 1 February 2015
- Published by SAGE Publications in Bio-Medical Materials and Engineering
- Vol. 26 (1_suppl) , S1087-S1093
Removal of baseline wandering in ECG signal by improved detrending method
The very first step to process electrocardiogram (ECG) signal is to eliminate baseline wandering interference that is usually caused by electrode-skin impedance mismatch, motion artifacts due to a patient’s body moment or respiratory breathing. A new method is thus suggested to remove baseline wandering in ECG by improving the detrending method that was originally proposed for eliminating slow non-stationary trends from heart rate variability (HRV). In our proposed method, a global trend is estimated in terms of baseline wandering by merging the local trend based on an ECG segment that represents a part of the ECG signal. The experimental results show that the improved detrending method can efficiently resolve baseline wandering without distorting any morphological characteristic embedded in the ECG signal in no time delay manner.
- 1 February 2015
- Published by SAGE Publications in Bio-Medical Materials and Engineering
- Vol. 26 (1_suppl) , S1087-S1093
Open AccessRemoval of baseline wandering in ECG signal by improved detrending method
The very first step to process electrocardiogram (ECG) signal is to eliminate baseline wandering interference that is usually caused by electrode-skin impedance mismatch, motion artifacts due to a patient’s body moment or respiratory breathing. A new method is thus suggested to remove baseline wandering in ECG by improving the detrending method that was originally proposed for eliminating slow non-stationary trends from heart rate variability (HRV). In our proposed method, a global trend is estimated in terms of baseline wandering by merging the local trend based on an ECG segment that represents a part of the ECG signal. The experimental results show that the improved detrending method can efficiently resolve baseline wandering without distorting any morphological characteristic embedded in the ECG signal in no time delay manner.
- Open Access
- 1 February 2015
- Published by SAGE Publications in Bio-Medical Materials and Engineering
- Vol. 26 (1_suppl) , S1223-S1230
Enhancement of objects in photoacoustic tomography using selective filtering
Here we developed a real-time photoacoustic tomography (PAT) imaging acquisition device based on the linear array transducer utilized on ultrasonic devices. Also, we produced a phantom including diverse contrast media and acquired PAT imaging as the light source wavelength was changing to see if the contrast media reacted. Indocyanine green showed the highest reaction around the 800-nm band, methylene blue demonstrated the same in the 750-nm band, and gold nanoparticle showed the same in the 700-nm band. However, in the case of superparamagnetic iron oxide, we observed not reaction within the wavelength bands used herein to obtain imaging. Moreover, we applied selective filtering to the acquired PAT imaging to remove noise from around and reinforce the object’s area. Consequentially, we could see the object area in the imaging was effectively detected and the image noise was removed.
- 1 February 2015
- Published by SAGE Publications in Bio-Medical Materials and Engineering
- Vol. 26 (1_suppl) , S1223-S1230
Open AccessEnhancement of objects in photoacoustic tomography using selective filtering
Here we developed a real-time photoacoustic tomography (PAT) imaging acquisition device based on the linear array transducer utilized on ultrasonic devices. Also, we produced a phantom including diverse contrast media and acquired PAT imaging as the light source wavelength was changing to see if the contrast media reacted. Indocyanine green showed the highest reaction around the 800-nm band, methylene blue demonstrated the same in the 750-nm band, and gold nanoparticle showed the same in the 700-nm band. However, in the case of superparamagnetic iron oxide, we observed not reaction within the wavelength bands used herein to obtain imaging. Moreover, we applied selective filtering to the acquired PAT imaging to remove noise from around and reinforce the object’s area. Consequentially, we could see the object area in the imaging was effectively detected and the image noise was removed.
- 1 June 2012
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 106 (3) , 260-273
Availability of a newly devised ambulatory urodynamics monitoring system based on personal device assistance in patients with spinal cord injury
- 1 June 2012
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 106 (3) , 260-273
Availability of a newly devised ambulatory urodynamics monitoring system based on personal device assistance in patients with spinal cord injury
- Open Access
- 1 January 2012
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 11 (1) , 37
Patterned thin metal film for the lateral resolution measurement of photoacoustic tomography
Image quality assessment method of photoacoustic tomography has not been completely standardized yet. Due to the combined nature of photonic signal generation and ultrasonic signal transmission in biological tissue, neither optical nor ultrasonic traditional methods can be used without modification. An optical resolution measurement technique was investigated for its feasibility for resolution measurement of photoacoustic tomography. A patterned thin metal film deposited on silica glass provides high contrast in optical imaging due to high reflectivity from the metal film and high transmission from the glass. It provides high contrast when it is used for photoacoustic tomography because thin metal film can absorb pulsed laser energy. An US Air Force 1951 resolution target was used to generate patterned photoacoustic signal to measure the lateral resolution. Transducer with 2.25 MHz bandwidth and a sample submerged in water and gelatinous block were tested for lateral resolution measurement. Photoacoustic signal generated from a thin metal film deposited on a glass can propagate along the surface or through the surrounding medium. First, a series of experiments with tilted sample confirmed that the measured photoacoustic signal is what is propagating through the medium. Lateral resolution of the photoacoustic tomography system was successfully measured for water and gelatinous block as media: 0.33 mm and 0.35 mm in water and gelatinous material, respectively, when 2.25 MHz transducer was used. Chicken embryo was tested for biomedical applications. A patterned thin metal film sample was tested for its feasibility of measuring lateral resolution of a photoacoustic tomography system. Lateral resolutions in water and gelatinous material were successfully measured using the proposed method. Measured resolutions agreed well with theoretical values.
- 1 January 2012
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 11 (1) , 37
Open AccessPatterned thin metal film for the lateral resolution measurement of photoacoustic tomography
Image quality assessment method of photoacoustic tomography has not been completely standardized yet. Due to the combined nature of photonic signal generation and ultrasonic signal transmission in biological tissue, neither optical nor ultrasonic traditional methods can be used without modification. An optical resolution measurement technique was investigated for its feasibility for resolution measurement of photoacoustic tomography. A patterned thin metal film deposited on silica glass provides high contrast in optical imaging due to high reflectivity from the metal film and high transmission from the glass. It provides high contrast when it is used for photoacoustic tomography because thin metal film can absorb pulsed laser energy. An US Air Force 1951 resolution target was used to generate patterned photoacoustic signal to measure the lateral resolution. Transducer with 2.25 MHz bandwidth and a sample submerged in water and gelatinous block were tested for lateral resolution measurement. Photoacoustic signal generated from a thin metal film deposited on a glass can propagate along the surface or through the surrounding medium. First, a series of experiments with tilted sample confirmed that the measured photoacoustic signal is what is propagating through the medium. Lateral resolution of the photoacoustic tomography system was successfully measured for water and gelatinous block as media: 0.33 mm and 0.35 mm in water and gelatinous material, respectively, when 2.25 MHz transducer was used. Chicken embryo was tested for biomedical applications. A patterned thin metal film sample was tested for its feasibility of measuring lateral resolution of a photoacoustic tomography system. Lateral resolutions in water and gelatinous material were successfully measured using the proposed method. Measured resolutions agreed well with theoretical values.
- 1 December 2011
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 104 (3) , 426-434
Estimation algorithm of the bowel motility based on regression analysis of the jitter and shimmer of bowel sounds
- 1 December 2011
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 104 (3) , 426-434
Estimation algorithm of the bowel motility based on regression analysis of the jitter and shimmer of bowel sounds
- Open Access
- 10 August 2011
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 10 (1) , 69
Non-invasive algorithm for bowel motility estimation using a back-propagation neural network model of bowel sounds
Background: Radiological scoring methods such as colon transit time (CTT) have been widely used for the assessment of bowel motility. However, these radiograph-based methods need cumbersome radiological instruments and their frequent exposure to radiation. Therefore, a non-invasive estimation algorithm of bowel motility, based on a back-propagation neural network (BPNN) model of bowel sounds (BS) obtained by an auscultation, was devised. Methods: Twelve healthy males (age: 24.8 ± 2.7 years) and 6 patients with spinal cord injury (6 males, age: 55.3 ± 7.1 years) were examined. BS signals generated during the digestive process were recorded from 3 colonic segments (ascending, descending and sigmoid colon), and then, the acoustical features (jitter and shimmer) of the individual BS segment were obtained. Only 6 features (J 1, 3 , J 3, 3 , S 1, 2 , S 2, 1 , S 2, 2 , S 3, 2 ), which are highly correlated to the CTTs measured by the conventional method, were used as the features of the input vector for the BPNN. Results: As a results, both the jitters and shimmers of the normal subjects were relatively higher than those of the patients, whereas the CTTs of the normal subjects were relatively lower than those of the patients (p < 0.01). Also, through k-fold cross validation, the correlation coefficient and mean average error between the CTTs measured by a conventional radiograph and the values estimated by our algorithm were 0.89 and 10.6 hours, respectively. Conclusions: The jitter and shimmer of the BS signals generated during the peristalsis could be clinically useful for the discriminative parameters of bowel motility. Also, the devised algorithm showed good potential for the continuous monitoring and estimation of bowel motility, instead of conventional radiography, and thus, it could be used as a complementary tool for the non-invasive measurement of bowel motility.
- 10 August 2011
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 10 (1) , 69
Open AccessNon-invasive algorithm for bowel motility estimation using a back-propagation neural network model of bowel sounds
Background: Radiological scoring methods such as colon transit time (CTT) have been widely used for the assessment of bowel motility. However, these radiograph-based methods need cumbersome radiological instruments and their frequent exposure to radiation. Therefore, a non-invasive estimation algorithm of bowel motility, based on a back-propagation neural network (BPNN) model of bowel sounds (BS) obtained by an auscultation, was devised. Methods: Twelve healthy males (age: 24.8 ± 2.7 years) and 6 patients with spinal cord injury (6 males, age: 55.3 ± 7.1 years) were examined. BS signals generated during the digestive process were recorded from 3 colonic segments (ascending, descending and sigmoid colon), and then, the acoustical features (jitter and shimmer) of the individual BS segment were obtained. Only 6 features (J 1, 3 , J 3, 3 , S 1, 2 , S 2, 1 , S 2, 2 , S 3, 2 ), which are highly correlated to the CTTs measured by the conventional method, were used as the features of the input vector for the BPNN. Results: As a results, both the jitters and shimmers of the normal subjects were relatively higher than those of the patients, whereas the CTTs of the normal subjects were relatively lower than those of the patients (p < 0.01). Also, through k-fold cross validation, the correlation coefficient and mean average error between the CTTs measured by a conventional radiograph and the values estimated by our algorithm were 0.89 and 10.6 hours, respectively. Conclusions: The jitter and shimmer of the BS signals generated during the peristalsis could be clinically useful for the discriminative parameters of bowel motility. Also, the devised algorithm showed good potential for the continuous monitoring and estimation of bowel motility, instead of conventional radiography, and thus, it could be used as a complementary tool for the non-invasive measurement of bowel motility.
- Open Access
- 1 June 2011
- Published by The Korean Institute of Electrical Engineers in The Transactions of The Korean Institute of Electrical Engineers
- Vol. 60 (6) , 1209-1214
Principles and Medical Applications of Biomedical Photoacoustic Tomography
- 1 June 2011
- Published by The Korean Institute of Electrical Engineers in The Transactions of The Korean Institute of Electrical Engineers
- Vol. 60 (6) , 1209-1214
Open AccessPrinciples and Medical Applications of Biomedical Photoacoustic Tomography
- 17 June 2010
- Published by Springer Nature in Journal of Medical Systems
- Vol. 36 (2) , 715-722
An Acoustical Evaluation of Knee Sound for Non-invasive Screening and Early Detection of Articular Pathology
Knee sound signals generated by knee movement are sometimes associated with degeneration of the knee joint surface and such sounds may be a useful index for early disease. In this study, we detected the acoustical parameters, such as the fundamental frequency (F0), mean amplitude of the pitches, and jitter and shimmer of knee sounds, and compared them according to the pathological conditions. Six normal subjects (4 males and 2 females, age: 28.3 ± 2.3 years) and 11 patients with knee problems were enrolled. The patients were divided into the 1st patient group (5 males and 1 female, age: 30.2 ± 10.3 years) with ruptured wounds of the meniscus and 2nd patient group (2 males and 3 females, age: 42.1 ± 16.2 years) with osteoarthritis. The mean values of F0, jitter and shimmer of the 2nd patient group were larger than those of the normal group, whereas those of the 1st patient group were smaller (p < 0.05). Also, the F0 and jitter in the standing position were larger than those in the sitting position in both the 1st and 2nd patient groups (p < 0.05). These results showed good potential for the non-invasive diagnosis and early detection of articular pathologies via an auscultation.
- 17 June 2010
- Published by Springer Nature in Journal of Medical Systems
- Vol. 36 (2) , 715-722
An Acoustical Evaluation of Knee Sound for Non-invasive Screening and Early Detection of Articular Pathology
Knee sound signals generated by knee movement are sometimes associated with degeneration of the knee joint surface and such sounds may be a useful index for early disease. In this study, we detected the acoustical parameters, such as the fundamental frequency (F0), mean amplitude of the pitches, and jitter and shimmer of knee sounds, and compared them according to the pathological conditions. Six normal subjects (4 males and 2 females, age: 28.3 ± 2.3 years) and 11 patients with knee problems were enrolled. The patients were divided into the 1st patient group (5 males and 1 female, age: 30.2 ± 10.3 years) with ruptured wounds of the meniscus and 2nd patient group (2 males and 3 females, age: 42.1 ± 16.2 years) with osteoarthritis. The mean values of F0, jitter and shimmer of the 2nd patient group were larger than those of the normal group, whereas those of the 1st patient group were smaller (p < 0.05). Also, the F0 and jitter in the standing position were larger than those in the sitting position in both the 1st and 2nd patient groups (p < 0.05). These results showed good potential for the non-invasive diagnosis and early detection of articular pathologies via an auscultation.
- 11 February 2010
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7554
A study on the qualitative morphological features of the muscle and subcutaneous shapes in vivo using Fourier-domain common path OCT
In this paper, we have demonstrated a polarization sensitive subcutaneous and muscle imaging based on common path optical coherence tomography (CP-OCT) using near infrared source. The axial and lateral resolutions of our PS-OCT system are 9μm and 6μm, respectively. The internal structural information has been extracted by the real-time signal analysis (Fourier Transform) from the modulated spectral intensity depending on the beam and tissue birefringence. Preliminary results using fresh beef and in vivo rat show that we can visualize the birefringence effect of the tissue collagen fibers in the samples for better image contrast and sensitivity for detection of hidden dermal structures. Compared to conventional CP-OCT, our proposed PS-OCT could provide depth-resolved images, which reflect tissue birefringence.
- 11 February 2010
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7554
A study on the qualitative morphological features of the muscle and subcutaneous shapes in vivo using Fourier-domain common path OCT
In this paper, we have demonstrated a polarization sensitive subcutaneous and muscle imaging based on common path optical coherence tomography (CP-OCT) using near infrared source. The axial and lateral resolutions of our PS-OCT system are 9μm and 6μm, respectively. The internal structural information has been extracted by the real-time signal analysis (Fourier Transform) from the modulated spectral intensity depending on the beam and tissue birefringence. Preliminary results using fresh beef and in vivo rat show that we can visualize the birefringence effect of the tissue collagen fibers in the samples for better image contrast and sensitivity for detection of hidden dermal structures. Compared to conventional CP-OCT, our proposed PS-OCT could provide depth-resolved images, which reflect tissue birefringence.